AT&T 2.1.1 manual Configuring DCP Extensions Integrated Only

Page 50

System 75 and DEFINITY G1 Initial Implementation

6.Enter LWC Reception: according to the following table:

Release Setting

R1V1 y

R1V2 yes

R1V3 ap-spe

G1msa-spe

7.Enter Call Waiting Indication? as n.

8.Enter Att. Call Waiting Indication? as n.

Leave the remaining fields at default values. Repeat this procedure for each extension assigned to an AUDIX Voice Power analog channel.

Configuring DCP Extensions

(Integrated Only)

To integrate the switch to AUDIX Voice Power, a digital station must be configured. See Figure 3-5.

Use the following procedure and the appropriate station command (add station or change station) to configure the DCP extension:

1.Enter Type: as PC.

NOTE:

If your switch is a R1V1 software vintage, the station type should be assigned as a 7405D set.

2.Enter Set: as 7404D.

3.Enter COR as 16 or whatever COR was assigned to the DCP connection extension. (See Figure 3-3.)

4.Set Restrict Last Appearance? to y.

5.Set all ten button assignments to call-appr.

6.Enter normal for Button 1 under DISPLAY BUTTON ASSIGNMENTS

(Page 3) or FEATURE BUTTON ASSIGNMENTS (Page 2).

7.Set Data Module? to y.

This data module is actually a dummy extension that will not be used for AUDIX Voice Power. When assigning this extension, it is recommended that you select an obscure extension that will not be needed in the future, but which is a valid number in the dial plan.

3-10

Image 50
Contents Audix Voice Power 1991 AT&T All Rights Reserved Trademark NoticeContents System 75 and Definity G1 Initial Implementation IndexFigures About This Guide Purpose and ScopeIntended Audience AssistanceHow to Use This Guide Conventions Used in this GuideInformation Conventions Related Documents SystemOverview Integrated SystemsSpeech Hardware ConfigurationNon-Integrated Systems Disk SizeSoftware Configuration Unix Operating SystemTesting Extensions and Connections Channel Assignments Service ExtensionAssigning Information Service for Testing Reaching the Configuration Management MenuContinue with Entering the Channel Assignments for Testing Entering the Channel Assignments for Testing Voice Equipment window appearsCHN CD.PT State Page Placing All Channels In Service for Testing Page Page Verifying Extensions Mapping the Phone Extensions to Channels Integrated Only Voice Equipment and press Enter Page Page Actual Service Assigning Services to ChannelsActual Service Provided on Integrated Systems Assigned Service Direct Call Coverage CallActual Service Provided on Non-Integrated Systems Entering Service Assignments Voice Equipment window appears Press F8 CHG-KEYS Page Audix Voice Power Initial Implementation Press F3 Save Changing Service AssignmentsChanging Switch Interface Parameters Switch Interface Administration ParametersSwitch Interface Administration Voice System Administration menu appears Switch Interface Administration form appears Page Verifying System Parameters Verifying Message Waiting Lamp ParametersDisplaying Feature Access Codes System 75/DEFINITY G1 Feature Access Code FormSystem Parameter Administration Entering System ParametersSystem 75 and Definity G1 Initial Implementation Verifying Software ReleaseMusic On Hold Accessing the DCP Extension R1V1Release R1V1 and R1V2 Software Limitations Stations Supported R1V1 Accessing the DCP Extension R1V2Upgrade Installation Audix Voice Power Checklist Integrated Only Assigning Class of Restrictions28? y 36? y 44? y 52? y Class of Restriction Verifying Analog Charnel Administration Enter Type as Configuring DCP Extensions Integrated Only System 75 and Definity G1 Initial Implementation Integrated Mode Administering Hunt GroupsNon-Integrated Mode Creating Hunt Groups Hunt GroupAdministering Call Coverage Creating Coverage PathsPerforming Subscriber Administration Changing Coverage PathsAssign LWC Activation? as y Administering Trunk Names Integrated Only Press Enter Application Package Administration menu appears Press any key to continue Handling Ambiguous Extensions Handling Display PhonesIndex IN-1IN-2 Index