Panasonic AG-RT850P manual Alarm recording duration setting, 0Alarm recall see, 5Video signal mode

Page 10

Menu Screens

MENU SCREEN 3

The alarm recording mode and terminal output are set on Menu Screen 3.

iAlarm recording mode selection (see page 20) The recording mode in the event of an alarm input is selected. (OFF ALARM)

ALARM: When there is an alarm input during recording in the time lapse mode, the recording time mode is switched to 6H (alarm recording) and the details of the alarm status are recorded faithfully.

OFF: Alarm recording is not possible even when an alarm signal is input during recording.

oAlarm recording duration setting

This sets the time elapsing from the start of alarm recording until its end. (30SEC 1MIN 2MIN 3MIN 5MIN 10MIN CONTINUE MANUAL 30SEC...)

CONTINUE: Alarm recording continues until the tape end.

MANUAL: Alarm recording is performed while the alarm input continues.

!0Alarm recall (see page 20)

This checks the date/time (up to 4) of the alarm signals.

!1Terminal connector output signal setting

ERR WARN: When trouble has occurred in the unit (AUTO OFF), the LOW signal is output.

REC: The LOW signal is output during recording.

MENU SCREEN 4

Recording mode and video output are selected on Menu Screen 4.

!2Recording time mode selection (see page 14) When recording starts, the set time mode is always established.

(OFF 6H L18H L24H 48H 72H 96H 120H 168H 180H 240H OFF...) OFF: Any time mode can be set using the TIME MODE button on the front panel. It can be changed even while recording is in progress.

6H: 6-hour mode (compatible with the standard mode of ordinary VTRÕs).

L18H/L24H: L18-/L24-hour mode (linear slow recording).

48H/72H/96H/120H/168H/180H/240H: 48-/72-/96-/120-/168-/180-/240-hour mode (time lapse recording).

!3Selection of VTR operation when cassette is inserted

STOP: Stop mode

REC: Simply by inserting the cassette tape, record- ing is started automatically.

REWREC: When the cassette is inserted, it is first rewound to the start of the tape and then recording is started automatically.

!4Selection of operation when tape end is de- tected during recording (see page 18)

STOP: Stop mode

REW: The tape is automatically rewound to the start where it stops.

REPEAT: The tape is automatically rewound to the start, and recording is repeated.

EJECT: The tape is ejected.

!5Video signal mode

This selects the operation of the color/black-and- white automatic selector circuit.

AUTO: The circuit automatically identifies the type of video input or playback signals, and selects the color or black-and-white mode accordingly.

COLOR: The color mode is forcibly established.

B_W: The black-and-white mode is forcibly established.

!6Playback picture quality selection

The detail of the playback images can be emphasized.

OFF: Regular mode

ON: The playback picture has emphasized outlines.

MENU SCREEN 5

The internal timer recording modes are set on Menu Screen 5.

!7Internal timer recording mode setting (see page

Note:

16)

Internal timer recording does not operate when the

This sets the weekly timer or daily timer recording

date and time have not been set.

mode. (OFF/ON)

 

OFF: Internal timer recording is not set.

 

ON: Internal timer recording is set. (The start and

 

stop times are set.)

 

10

Image 10
Contents Operating Instructions FCC Note Do not OpenContents Features Regular Maintenance Service RecommendationAction taken after routine inspections Routine inspection procedureRoutine & Regular Inspection Request Regular inspections recommendedParts and Their Functions @1ALARM display lamp 6RESET button8TIME Mode , buttons 5Tracking -, +/V-LOCK buttonVideo input/output connectors Camera switching output connectorAudio input/output connectors AC in connectorMenu Screens 1Terminal connector output signal setting Alarm recording duration setting0Alarm recall see 5Video signal mode9Setting the start time for the daylight savings mode @0Setting the end time for the daylight savings modeDate and Time Settings TIME/DATE display position adjustment function Time/Date Display PositionL18 hours Time Mode SelectionTape type Mode Recordable time Hours 160 L24 hoursBefore power is restored After power is restored Recording ProcedureRecording Mode Lock Tips For Better RecordingTimer Recording Internal Timer RecordingDaily Recording Daily Timer/Weekly Recording Weekly Timer SAT on 800 L24 DLY on 800 L18External timer recording operations External Timer RecordingAuto Repeat Recording/Auto Rewinding Alarm and Display Methods during Alarm Recording Alarm Recording Emergency RecordingPrinciple of Alarm Recording Connecting the Alarm Input ConnectorAlarm Recording Operation Alarm RecallWJ-FS616 Frame Switcher Connection and RecordingConnections using the WJ-FS616 Time Lapse VTR AG-RT850Vertical Hold Adjustment Playback ProcedureTracking DUB 9-pin connector specifications RS-232C Interface¥ Response message ¥ Command receive verificationExample Explanatory descriptionTable of commands Command Command parameter Completion message InterruptibleID request command Time mode switching commandCounter data request command Time mode request commandTime setting command ACK return status request commandAll status request command Automatic send setting commandTrouble with functions or operation TroubleshootingTrouble with installation Trouble with recordingTrouble with playback Specifications Input/Output Terminal Signal LevelPage Security & Digital Imaging Company