Panasonic AG-RT850P manual Alarm Recording Emergency Recording, Principle of Alarm Recording

Page 19

Alarm Recording (Emergency Recording)

When an emergency occurs at the monitoring site during prolonged monitoring and recording, the alarm function is automatically triggered, and alarm recording is performed.

Principle of Alarm Recording

Alarm input

Alarm reset input

Tape start

 

 

Tape end

L18 to 240 hours

6 hours

 

L18 to 240 hours

Time lapse mode

Alarm mode

Time lapse mode

¥When an alarm signal is supplied by an alarm sensor (door or intercom switch, etc.) during recording in a time lapse mode, the recording speed is switched to the 6-hour mode and the details of the state of emer- gency are faithfully recorded.

Alarm and Display Methods during Alarm Recording

 

EJECT REC REVIEW

REC

 

REC

 

PULL OPEN

 

 

 

REV

FWD

TRACKING /

COUNTER /

 

V-LOCK RESET

TIME MODE SEARCH

 

 

ALARM

 

ALARM display lamp

¥When an alarm signal is supplied, the alarm display lamp functions as follows.

Alarm

On

 

 

Flashing

 

 

Off

lamp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm input

 

Alarm reset

Power switch is

 

 

 

 

input

pressed twice.

 

 

 

 

 

 

Display

 

 

 

 

 

 

 

 

 

 

 

switches to

 

 

 

 

 

 

Ò6HÓ.

11-17-01 6H

 

 

 

 

 

 

 

 

 

 

10:14:30 A

 

 

 

 

ÒAÓ display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TV monitor

 

 

 

appears

Connecting the Alarm Input

Connector

Alarm switch

 

CAMERA

 

 

SW OUT

IN

 

 

AUDIO

 

 

OUT

AC IN

ALARM RESET IN

TAPE END OUT

ALARM IN

 

WARNING/

COMMON REC IN

REC OUT

Alarm switch

 

 

Alarm reset switch

 

 

4 V Ð 14 V

 

 

¥Alarm recording starts when the alarm switch is set on. When the alarm reset switch is set ON after recording has started, alarm recording is released and operation is returned to the original time lapse recording mode.

¥Alarm recording can be released by pressing the STOP button during alarm recording.

However, it cannot be released even by pressing the STOP button if the MENU/REC LOCK switch is at REC LOCK or INT is lighted on the display.

¥Alarm recording can be automatically reset without supplying the alarm reset input signal.

The reset time can be set for 0.5, 1, 2, 3, 5 or 10 minutes.

¥Another option is alarm recording only while the alarm input signal is supplied.

¥Alarm recording is also possible as far as the end of the tape.

¥When the alarm mode is OFF, alarm recording is not possible even if the alarm switch is set to ON.

19

Image 19
Contents Operating Instructions Do not Open FCC NoteContents Regular Maintenance Service Recommendation FeaturesRegular inspections recommended Routine inspection procedureRoutine & Regular Inspection Request Action taken after routine inspectionsParts and Their Functions 5Tracking -, +/V-LOCK button 6RESET button8TIME Mode , buttons @1ALARM display lampAC in connector Camera switching output connectorAudio input/output connectors Video input/output connectorsMenu Screens 5Video signal mode Alarm recording duration setting0Alarm recall see 1Terminal connector output signal setting@0Setting the end time for the daylight savings mode 9Setting the start time for the daylight savings modeDate and Time Settings Time/Date Display Position TIME/DATE display position adjustment functionL24 hours Time Mode SelectionTape type Mode Recordable time Hours 160 L18 hoursTips For Better Recording Recording ProcedureRecording Mode Lock Before power is restored After power is restoredInternal Timer Recording Timer RecordingSAT on 800 L24 DLY on 800 L18 Daily Recording Daily Timer/Weekly Recording Weekly TimerExternal timer recording operations External Timer RecordingAuto Repeat Recording/Auto Rewinding Connecting the Alarm Input Connector Alarm Recording Emergency RecordingPrinciple of Alarm Recording Alarm and Display Methods during Alarm RecordingAlarm Recall Alarm Recording OperationTime Lapse VTR AG-RT850 Frame Switcher Connection and RecordingConnections using the WJ-FS616 WJ-FS616Vertical Hold Adjustment Playback ProcedureTracking RS-232C Interface DUB 9-pin connector specificationsExplanatory description ¥ Command receive verificationExample ¥ Response messageCommand Command parameter Completion message Interruptible Table of commandsTime mode request command Time mode switching commandCounter data request command ID request commandAutomatic send setting command ACK return status request commandAll status request command Time setting commandTrouble with recording TroubleshootingTrouble with installation Trouble with functions or operationTrouble with playback Input/Output Terminal Signal Level SpecificationsPage Security & Digital Imaging Company