Panasonic AG-RT850P manual Routine & Regular Inspection Request, Routine inspection procedure

Page 5

Routine & Regular Inspection Request

This unit is designed to withstand many hours of operation. Nevertheless, it is recommended that routine inspections be conducted to help ensure trouble-free operation.

CAUTION

Do not forget to conduct the routine inspection with auto repeat recording.

Routine inspection procedure

qSet the power switches on the unit, video cameras, TV monitor and other equipment connected in the monitoring system to the ON position.

wIs the picture on the TV monitor OK?

tPress the TIME MODE button to set to the mode to 6H (6 hours).

TIME MODE

Display

yPress the PLAY button. The tape is played back by an amount equivalent to a count on the counter of several figures.

PLAY

eAre the date and time displayed on the TV monitor correct?

11-15-01 6H 10:10:55

uIs the playback image OK?

iIs there any problem with the recorded date and time?

oPress the REC button.

REC

rRewind the cassette tape, which was recorded on the previous day, by an amount equivalent to a count on the counter of several figures.

REW

!0Check the playback images which were recorded in the 6-hour time mode.

!1Upon completion of all the checks, set the unit to the desired mode.

Action taken after routine inspections

In the unlikely event of a problem with the unit, turn off the power, take hold of the power plug and disconnect it from the power outlet, and consult with the dealer from whom the unit was purchased.

Regular inspections recommended

This unit has an hour meter which shows for how many hours the VTR has been used. When the MENU/REC LOCK switch is set to MENU, Menu Screen 1 appears on the TV monitor, and the hour meter can be checked. Use the hour meter as a rough guideline to cleaning or replacing the parts inside the unit. For further details, consult with your dealer.

MENU

OFF

REC LOCK

[HOUR METER] 00000H

TV monitor

5

Image 5
Contents Operating Instructions Do not Open FCC NoteContents Regular Maintenance Service Recommendation FeaturesRoutine & Regular Inspection Request Routine inspection procedureAction taken after routine inspections Regular inspections recommendedParts and Their Functions 8TIME Mode , buttons 6RESET button@1ALARM display lamp 5Tracking -, +/V-LOCK buttonAudio input/output connectors Camera switching output connectorVideo input/output connectors AC in connectorMenu Screens 0Alarm recall see Alarm recording duration setting1Terminal connector output signal setting 5Video signal mode@0Setting the end time for the daylight savings mode 9Setting the start time for the daylight savings modeDate and Time Settings Time/Date Display Position TIME/DATE display position adjustment functionTape type Mode Recordable time Hours 160 Time Mode SelectionL18 hours L24 hoursRecording Mode Lock Recording ProcedureBefore power is restored After power is restored Tips For Better RecordingInternal Timer Recording Timer RecordingSAT on 800 L24 DLY on 800 L18 Daily Recording Daily Timer/Weekly Recording Weekly TimerAuto Repeat Recording/Auto Rewinding External Timer RecordingExternal timer recording operations Principle of Alarm Recording Alarm Recording Emergency RecordingAlarm and Display Methods during Alarm Recording Connecting the Alarm Input ConnectorAlarm Recall Alarm Recording OperationConnections using the WJ-FS616 Frame Switcher Connection and RecordingWJ-FS616 Time Lapse VTR AG-RT850Tracking Playback ProcedureVertical Hold Adjustment RS-232C Interface DUB 9-pin connector specificationsExample ¥ Command receive verification¥ Response message Explanatory descriptionCommand Command parameter Completion message Interruptible Table of commandsCounter data request command Time mode switching commandID request command Time mode request commandAll status request command ACK return status request commandTime setting command Automatic send setting commandTrouble with installation TroubleshootingTrouble with functions or operation Trouble with recordingTrouble with playback Input/Output Terminal Signal Level SpecificationsPage Security & Digital Imaging Company