Panasonic AG-RT850P manual Internal Timer Recording

Page 16

Timer Recording

There are two methods of timer recording: one uses the internal timer and the other uses an external timer.

Internal Timer Recording

Start time and stop time

Bear in mind the following points when setting these times.

When the stop time is set later than the start time: Recording will commence at the start time on the day concerned and stop at the end time on the same day. Example: 8:30 17:00

When the start time is set later than the stop time or the start time and stop time for weekly record- ing (weekly timer) are the same:

Recording starts at the start time on the day con- cerned and ends at the stop time on the following day. Example: 17:00 8:30

When the start time and stop time are the same (for weekly recording):

Recording starts at 8:30 on the day concerned and ends at 8:30 on the following day.

Example: 8:30 8:30

To record for an entire day, set the start time and stop time to 0:00.

¥Weekly recording (weekly timer) can be set by the day of the week.

¥When (INTERNAL TIMER REC) on Menu Screen 5 is set to OFF for both the weekly timer and daily recording (daily timer), nothing appears for the start or stop time. Timer recording is considered not to be set.

Internal timer recording operation

qCheck that a video cassette with its tab intact has been inserted.

wCheck that the TV monitor shows the correct pres- ent time.

e Set the MENU/REC LOCK switch to MENU to display the menu screens. Press the page button so that the INTERNAL TIMER REC timer setting screen appears on the TV monitor.

[INTERNAL TIMER REC] P5

[TIMER]START END T-M SUN OFF

MON OFF

TUE OFF

WED OFF

THU OFF

FRI OFF

SAT OFF

DLY OFF

VTR operations after the settings

¥The unitÕs power is turned off, and even if other but- tons are pressed, their operations are not accepted.

¥When the start time and stop time have not been set, INT flashes on the display.

Releasing the internal timer mode

Set the TIMER MODE switch to OFF to clear INT on the display.

Note:

¥Since it takes some moments for recording to start, set the start time for timer recording one minute earlier.

rSet the operation times of the internal timer.

¥For details on the settings, refer to the sections on ÒDaily timerÓ or ÒWeekly timer.Ó (See page 17.)

tUpon completion of the settings, set the MENU/ REC LOCK switch to OFF. The regular screen is restored.

ySet the TIMER MODE switch to INT TIMER so that INT lights on the display.

When the time and date for Menu Screen 1 have not been set, a cassette has not been inserted, the timer has not been set, or when a cassette with a broken out tab has been inserted, the buzzer sounds and INT flashes on the display.

16

Image 16
Contents Operating Instructions FCC Note Do not OpenContents Features Regular Maintenance Service RecommendationRoutine inspection procedure Routine & Regular Inspection RequestAction taken after routine inspections Regular inspections recommendedParts and Their Functions 6RESET button 8TIME Mode , buttons@1ALARM display lamp 5Tracking -, +/V-LOCK buttonCamera switching output connector Audio input/output connectorsVideo input/output connectors AC in connectorMenu Screens Alarm recording duration setting 0Alarm recall see1Terminal connector output signal setting 5Video signal mode9Setting the start time for the daylight savings mode @0Setting the end time for the daylight savings modeDate and Time Settings TIME/DATE display position adjustment function Time/Date Display PositionTime Mode Selection Tape type Mode Recordable time Hours 160L18 hours L24 hoursRecording Procedure Recording Mode LockBefore power is restored After power is restored Tips For Better RecordingTimer Recording Internal Timer RecordingDaily Recording Daily Timer/Weekly Recording Weekly Timer SAT on 800 L24 DLY on 800 L18External timer recording operations External Timer RecordingAuto Repeat Recording/Auto Rewinding Alarm Recording Emergency Recording Principle of Alarm RecordingAlarm and Display Methods during Alarm Recording Connecting the Alarm Input ConnectorAlarm Recording Operation Alarm RecallFrame Switcher Connection and Recording Connections using the WJ-FS616WJ-FS616 Time Lapse VTR AG-RT850Vertical Hold Adjustment Playback ProcedureTracking DUB 9-pin connector specifications RS-232C Interface¥ Command receive verification Example¥ Response message Explanatory descriptionTable of commands Command Command parameter Completion message InterruptibleTime mode switching command Counter data request commandID request command Time mode request commandACK return status request command All status request commandTime setting command Automatic send setting commandTroubleshooting Trouble with installationTrouble with functions or operation Trouble with recordingTrouble with playback Specifications Input/Output Terminal Signal LevelPage Security & Digital Imaging Company