Alarm Recording (Emergency Recording)
Alarm Recording Operation
qCheck that a video cassette with its tab intact has been inserted.
w Set the MENU/REC LOCK switch to MENU to display the menu screens. Press the page button to display the alarm recording setting screen (Menu Screen 3) on the TV monitor.
[ALARM]P3
MODE : OFF
DURATION : 30SEC
[RECALL] | - |
| - |
| - |
ePress the set (+ or Ð) button to display ALARM for MODE.
MODE : ALARM
rPress the shift ( ) button to move the flashing to
DURATION.
Press the set (+ or Ð) button to set the recording duration.
DURATION : 30SEC
tUpon completion of the settings, set the MENU/ REC LOCK switch to OFF. The regular screen is restored.
If an alarm input signal is subsequently supplied, the time mode set to 6H, and alarm recording continues until the alarm is released.
¥If TAPE END on Menu Screen 4 has been set to REPEAT, the auto repeat recording mode is established when the tape comes to the end. When auto repeat recording is to be performed, use an alarm recording interval setting other than MANUAL.
¥With emergency recording, set the unit to the POWER OFF or STOP mode.
Alarm Recall
The date and time when the alarm signal was input can be ascertained on the TV monitor by checking the alarm input time in the RECALL item on Menu Screen 3.
q Set the MENU/REC LOCK switch to MENU to display the menu screens. Press the page button to display the alarm recording setting screen (Menu Screen 3) on the TV monitor.
wUpon completion of the settings, set the MENU/ REC LOCK switch to OFF. The regular screen is restored.
[ALARM]P3
MODE : ALARM DURATION : 30SEC
[RECALL]
[OUTPUT SELECT] TERMINAL OUT : ERR WARN
¥The alarm recall function stores up to 4 alarm input times in the memory and displays them on the screen. If there have been more than 4 inputs, they will be deleted from the screen in sequence starting with the oldest data.
¥When the RESET button is pressed while Menu Screen 3 is on the display, the alarm recall memory can be cleared.
20