Panasonic AG-RT850P manual Trouble with playback

Page 29

The power has been restored after a

¥ Has the power failure lasted a long time (more than 1 week)?

power failure but recording does not

Set the timer recording switch to EXT to ensure that the unit is

automatically resume.

set to the recording mode even after a prolonged power failure.

 

 

Recording cannot be stopped.

¥ First set the MENU/REC LOCK switch to OFF and then operate.

 

¥ Is REC LOCK on Menu Screen 1 at OFF?

 

¥ Has the mode lock been applied through control exercised by the

 

RS-232C interface?

 

 

1-week programmed timer recording

¥ Are the date and time on the regular displays correct?

cannot be conducted properly.

(See page 12)

 

 

One or more cameras do not record

¥ Turn the time adjustment control on the frame switcher, and

when a multiple number of cameras are

adjust it to a setting which is longer than the video recording

used.

duration in the recording time mode.

 

¥ Connect a camera switching cable between the unit and frame

 

switcher. (See page 21)

 

 

No auto repeat recording.

¥ Has the stop button been pressed during auto rewinding?

 

 

No timer recording.

¥ Are the present time and start/stop times for the timer recording

 

correct?

 

¥ Has INT or EXT lighted on the display?

 

 

No alarm recording.

¥ Have the alarm sensors and alarm input connectors been

 

connected properly?

 

¥ Has the alarm recording mode been selected on Menu Screen 3?

 

Trouble with playback

 

 

Noise sometimes appears on the

¥ Adjust the tracking buttons. (See page 22)

playback pictures.

 

 

 

Dirty playback picture.

¥ The video heads may be dirty or clogged or they may have

 

reached the end of their service life. Consult with your dealer.

 

 

ÒSnowÓ on playback picture.

¥ The video heads may be dirty or clogged. Consult with your

 

dealer.

While a multiple number of cameras are being used, two scenes appear as the playback picture when the cameras are switched.

¥Has the camera switching signal cable been connected properly?

Recording starts when the unitÕs power plug is connected to or disconnected from the power outlet.

¥ Has INT or EXT lighted on the display?

No playback because recording starts when the main power for the connected equipment is set to ON.

¥ Has INT or EXT lighted on the display?

29

Image 29
Contents Operating Instructions Do not Open FCC NoteContents Regular Maintenance Service Recommendation FeaturesRoutine & Regular Inspection Request Routine inspection procedureAction taken after routine inspections Regular inspections recommendedParts and Their Functions 8TIME Mode , buttons 6RESET button@1ALARM display lamp 5Tracking -, +/V-LOCK buttonAudio input/output connectors Camera switching output connectorVideo input/output connectors AC in connectorMenu Screens 0Alarm recall see Alarm recording duration setting1Terminal connector output signal setting 5Video signal mode@0Setting the end time for the daylight savings mode 9Setting the start time for the daylight savings modeDate and Time Settings Time/Date Display Position TIME/DATE display position adjustment functionTape type Mode Recordable time Hours 160 Time Mode SelectionL18 hours L24 hoursRecording Mode Lock Recording ProcedureBefore power is restored After power is restored Tips For Better RecordingInternal Timer Recording Timer RecordingSAT on 800 L24 DLY on 800 L18 Daily Recording Daily Timer/Weekly Recording Weekly TimerAuto Repeat Recording/Auto Rewinding External Timer RecordingExternal timer recording operations Principle of Alarm Recording Alarm Recording Emergency RecordingAlarm and Display Methods during Alarm Recording Connecting the Alarm Input ConnectorAlarm Recall Alarm Recording OperationConnections using the WJ-FS616 Frame Switcher Connection and RecordingWJ-FS616 Time Lapse VTR AG-RT850Tracking Playback ProcedureVertical Hold Adjustment RS-232C Interface DUB 9-pin connector specificationsExample ¥ Command receive verification¥ Response message Explanatory descriptionCommand Command parameter Completion message Interruptible Table of commands Counter data request command Time mode switching command ID request command Time mode request commandAll status request command ACK return status request commandTime setting command Automatic send setting commandTrouble with installation TroubleshootingTrouble with functions or operation Trouble with recordingTrouble with playback Input/Output Terminal Signal Level SpecificationsPage Security & Digital Imaging Company