Mitsubishi Electronics
AJ65SBT-64AD
user manual
User,s Manual
Troubleshooting
Specs
I/O Conversion Characteristics
Install
Remote I/O Signals
Data Link Cable Wiring
Warranty
Maintenance
MELSEC-A System Configuration
Pre-Operation Procedure
Page 1
Analog-Digital
Converter Module type
AJ65SBT-64AD
User
,
s Manual
Mitsubishi Programmable Logic Controller
Page 1
Page 2
Image 1
Page 1
Page 2
Contents
User,s Manual
Safety Precautions
Installation Precautions
Starting and Maintenance Precautions
Manual number is given on the bottom left of the back cover
Revisions
Overview
Programming Procedure Program Examples
Setup and Preparation Before Operation
IB-66721
Model Code
13J872
IB-66251
Gppw
Product components This product consists of the following
Memo
Overview
MELSEC-A
Overall Configuration
MELSEC-A System Configuration
Applicable master modules
Applicable System
Restrictions on use of CC-Link dedicated instructions
General Specification
Specification
Performance Specification
I/O Conversion Characteristics
Voltage Input Characteristic
Voltage input characteristics
0mA
Current input characteristics
4mA
Accuracy
Resolution
Current Input Characteristic Accuracy Conversion speed
AJ65SBT-64AD function list
Function List
Moving average processing
Sampling processing
Sampling time 4000 2000
Stored second time Stored third time
Remote I/O signal list
Remote I/O Signals
Remote I/O Signals List
Remote I/O Signal Details 1/2
Functions of the remote I/O signals
Device No Signal Name RXn+1A
Remote I/O Signal Details 2/2
Initial data setting request
Flag RYn+1A Error reset request flag
Remote register allocation
Remote Register
2 A/D conversion enable/prohibit specification Address RWwm
B15 B12 b11 B8 b7 B4 b3 CH.4 CH.3 CH.2 CH.1
Input range setting Address RWwm+1
5 CH. Digital output value Address RWrn to RWrn+3
Moving average processing count setting Address RWwm+2
B15 B14 B13 B12 B11 B10 CH.4 CH.3 CH.2 CH.1
Times
Pre-Operation Procedure
MELSEC-A Setup and Preparation Before Operation
Precautions When Handling
Create a program When making offset/gain setting, set all
DIN rail DIN rail hook
Name of Each Part
Set Value Setting Switches Transmission Speed
Setting switches
Speed setting
Switches
Start
Offset/Gain Setting
Point
Facing Direction of the Module Installation
Station Number Setting
Wiring
Data Link Cable Wiring
Wiring precautions
Instructions for handling the CC-Link dedicated cables
Module connection example
Maintenance and Inspection
For voltage input
For current input
Memo
MELSEC-A Programming
Programming Procedure
Program Examples
Program example for power-on
MELSEC-A
Program example for initial data changing
MELSEC-A
Initial settings
Program example for power-on
Setting of automatic refresh parameters Checking
Program example for initial data changing
MELSEC-A
Program examples for use of the QnACPU
Automatic refresh parameter setting
Program example for initial data changing
Program examples for use of the Qcpu Q mode
Program for power-on
Setting results Setting results of 1 to 8 are shown below
Program for initial data changing
Using the Remote Input Signals to Check Errors
Troubleshooting
Error flag RXnC has turned on
Error status flag
Set the voltage value to within the range 20.4 to
Using the LED Indications to Check Errors
Specified value? 26.4V
To enter the test mode? Terminals across
Operation?
Power on again
If the L ERR. LED has begun flickering though
When the digital output value cannot be read
Revise the parameter settings
Is the L RUN LED lit?
AJ65SBT-64AD AJ65BT-64AD
Appendix
MELSEC-A
Appendix2 External dimension diagram
Memo
Ind
ERR.LED of the master station flickers
Memo
Warranty
User,s Manual
Top
Page
Image
Contents