Mitsubishi Electronics AJ65SBT-64AD user manual Performance Specification

Page 17

3 SPECIFICATION

3.2 Performance Specification

MELSEC-A

Table 3.2 indicates the performance specifications of the AJ65SBT-64AD.

Table 3.2 Performance specification

Item

 

 

 

 

 

 

Specification

 

 

 

 

Analog input

 

Voltage

 

 

 

DC -10 to +10V (input resistance 1M

)

 

 

 

 

Current

 

 

 

DC 0 to +20mA (input resistance 250

)

 

 

 

 

 

 

 

 

 

 

 

Digital output

 

 

 

 

16-bit signed binary (-4096 to +4095)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accuracy

 

 

 

 

 

 

 

 

Analog input range

 

Digital output

Ambient

 

Ambient

Max.

 

 

 

 

 

 

 

 

temperature

 

temperature

Resolution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 to 55°C

 

25±5°C

 

 

 

 

 

 

 

 

-10 to +10V

 

 

 

 

 

 

 

I/O characteristics, maximum

 

 

 

User range setting 1

 

-4000 to +4000

 

 

 

2.5mV

 

 

 

 

(-10 to +10V)

 

 

 

 

 

 

 

resolution, accuracy

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

0 to 5V

 

 

 

 

 

1.25mV

 

(accuracy relative to

 

 

 

 

 

 

 

 

 

 

 

1 to 5V

 

 

 

 

 

 

 

maximum value of digital

 

 

 

 

0 to 4000

±0.4%

 

±0.2%

 

 

 

 

 

User range setting 2

 

 

1.0mV

 

output value)

 

 

 

 

 

 

(±16 digit*)

 

(±8 digit*)

 

 

 

 

 

(0 to 5V)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 to 20mA

 

 

 

 

 

5µA

 

 

 

 

 

Current

 

4 to 20mA

 

0 to 4000

 

 

 

 

 

 

 

 

 

 

User range setting 3

 

 

 

 

4µA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0 to 20mA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* : digit indicates digital value.

 

 

 

 

 

 

 

 

 

Factory setting is -10 to +10V.

Maximum conversion speed

 

 

 

 

 

1ms/1 channel.

 

 

 

 

Absolute maximum input

 

 

 

 

Voltage ±15 V, current ±30mA

 

 

 

 

Analog input points

 

 

 

 

 

 

4 channels/1module

 

 

 

 

Number of occupied stations

 

 

 

1 station (RX/RY: each 32 points, RWr/RWw: each 4 points)

 

 

Connected terminal block

 

 

 

7-point, 2-piece terminal block (transmission, power supply)

 

 

 

 

 

Direct-coupled, 18-point terminal block (analog input section) (M3 screw)

 

 

 

 

 

 

 

 

 

 

Applicable wire size

 

 

 

 

 

0.3 to 0.75mm2

 

 

 

 

Applicable crimping terminal

 

 

 

RAV1.25-3.5 (conforming to JIS C2805)

 

 

Module mounting screw

 

 

M4 screw × 0.7mm × 16mm or more (tightening torque range: 78 to 108N cm)

 

 

 

Can also be mounted to DIN rail

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supported DIN rail

 

 

 

 

TH35-7.5Fe, TH35-7.5Al (conforming to JIS-C2B12)

 

 

External power supply

 

 

 

 

DC24V (DC20.4V to DC26.4V)

 

 

 

 

 

 

 

Inrush current :8.5A, within 2.3ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24VDC internal current

 

 

 

 

0.090

 

 

 

 

 

consumption (A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Noise immunity

 

 

By noise simulator of 500Vp-p noise voltage, 1µs noise width and 25 to 60Hz noise frequency

Dielectric withstand voltage

 

Between power supply/communication system batch and analog input batch: 500VAC, 1 minute

 

 

 

 

Across communication system terminals and all analog input terminals: Photocoupler isolated

Isolation system

 

 

Across power supply system terminals and all analog input terminals: Photocoupler isolated

 

 

 

 

 

 

 

Across channels: Non-isolated

 

 

 

 

Weight (kg)

 

 

 

 

 

0.20

 

 

 

 

 

Outline dimensions (mm)

 

 

 

 

 

118 (W) × 50 (H) × 40 (D)

 

 

 

 

3 - 2

Image 17
Contents User,s Manual Safety Precautions Installation Precautions Starting and Maintenance Precautions Manual number is given on the bottom left of the back cover RevisionsOverview Programming Procedure Program Examples Setup and Preparation Before OperationIB-66721 Model Code13J872 IB-66251Gppw Product components This product consists of the following Memo Overview MELSEC-A Overall Configuration MELSEC-A System ConfigurationRestrictions on use of CC-Link dedicated instructions Applicable SystemApplicable master modules General Specification SpecificationPerformance Specification I/O Conversion Characteristics Voltage Input Characteristic Voltage input characteristics4mA Current input characteristics0mA Accuracy ResolutionCurrent Input Characteristic Accuracy Conversion speed AJ65SBT-64AD function list Function ListMoving average processing Sampling processingSampling time 4000 2000 Stored second time Stored third timeRemote I/O Signals List Remote I/O SignalsRemote I/O signal list Remote I/O Signal Details 1/2 Functions of the remote I/O signalsDevice No Signal Name RXn+1A Remote I/O Signal Details 2/2Initial data setting request Flag RYn+1A Error reset request flagRemote register allocation Remote Register2 A/D conversion enable/prohibit specification Address RWwm B15 B12 b11 B8 b7 B4 b3 CH.4 CH.3 CH.2 CH.1 Input range setting Address RWwm+15 CH. Digital output value Address RWrn to RWrn+3 Moving average processing count setting Address RWwm+2B15 B14 B13 B12 B11 B10 CH.4 CH.3 CH.2 CH.1 TimesPre-Operation Procedure MELSEC-A Setup and Preparation Before OperationPrecautions When Handling Create a program When making offset/gain setting, set allDIN rail DIN rail hook Name of Each Part Set Value Setting Switches Transmission Speed Setting switchesSpeed setting SwitchesStart Offset/Gain SettingPoint Facing Direction of the Module Installation Station Number SettingWiring Data Link Cable WiringWiring precautions Instructions for handling the CC-Link dedicated cablesModule connection example Maintenance and InspectionFor voltage input For current inputMemo MELSEC-A Programming Programming ProcedureProgram Examples Program example for power-on MELSEC-A Program example for initial data changing MELSEC-A Initial settings Program example for power-on Setting of automatic refresh parameters Checking Program example for initial data changing MELSEC-A Program examples for use of the QnACPU Automatic refresh parameter setting Program example for initial data changing Program examples for use of the Qcpu Q mode Program for power-on Setting results Setting results of 1 to 8 are shown below Program for initial data changing Using the Remote Input Signals to Check Errors TroubleshootingError flag RXnC has turned on Error status flagSet the voltage value to within the range 20.4 to Using the LED Indications to Check ErrorsSpecified value? 26.4V To enter the test mode? Terminals acrossIf the L ERR. LED has begun flickering though Power on againOperation? When the digital output value cannot be read Revise the parameter settings Is the L RUN LED lit? AJ65SBT-64AD AJ65BT-64AD AppendixMELSEC-A Appendix2 External dimension diagram Memo Ind ERR.LED of the master station flickers Memo Warranty User,s Manual

AJ65SBT-64AD specifications

The Mitsubishi Electronics AJ65SBT-64AD is a high-performance programmable controller designed to meet the demanding requirements of modern automation systems. This module is part of the Mitsubishi FX series of programmable logic controllers (PLCs), known for their reliability, flexibility, and advanced features.

One of the standout features of the AJ65SBT-64AD is its ability to handle 64 analog input channels, making it ideal for applications that require precise monitoring of multiple signals. The module provides a seamless interface for connecting various sensors and transducers, enabling accurate data acquisition in real time. This capability is crucial for industrial environments where monitoring temperature, pressure, flow, and various other parameters is essential for optimal operation.

The AJ65SBT-64AD incorporates advanced signal processing technologies, ensuring high resolution and fast response times. This is particularly important in dynamic applications where rapid changes in process conditions can occur. Additionally, the module supports a wide range of input signal types, including voltage and current, allowing significant versatility in its use across different industries.

Another critical characteristic of the AJ65SBT-64AD is its integration within the Mitsubishi Electric automation ecosystem. This allows for seamless communication and data exchange with other Mitsubishi devices, enhancing system coherence and simplifying configuration processes. By leveraging the integrated engineering tools provided by Mitsubishi, including GX Works2 and GX Developer, users can efficiently program and monitor their systems, reducing downtime and enhancing productivity.

The module is designed with robust construction to withstand harsh industrial environments. Its durability and resistance to dust, moisture, and electromagnetic interference make it suitable for use in a wide range of applications, from manufacturing to process control.

Moreover, the AJ65SBT-64AD employs advanced diagnostics and fault detection capabilities. This functionality aids in preventive maintenance by providing real-time feedback on system performance and potential issues, ensuring that operations run smoothly with minimal interruptions.

In summary, the Mitsubishi Electronics AJ65SBT-64AD is a versatile and high-performance analog input module that offers numerous features tailored for automation applications. Its 64-channel capability, advanced signal processing, robust construction, and integration with Mitsubishi's ecosystem make it a valuable component for any modern industrial automation setup.