GTO 2550, 2502 installation manual Closed Position

Page 18

IMPORTANT: While determining the mounting point for the post pivot bracket assembly, be sure that the position allows for minimum 2 inches of clearance between the gate and the opener in both the open and closed positions, as shown in the diagrams below. This clearance will give the opener the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area.

Step 6

When you feel that you have the best position for the post pivot bracket in the open position, insert the 5/16" x 1-3/4" bolt through the aligned holes of the post bracket and post pivot bracket to hold it in place. Remove the clevis pin from the front mount and while supporting the gate opener, swing the gate and gate opener to the closed position. With the gate and gate opener in the closed position check the clearance and be sure that the gate opener is not binding at the post pivot bracket.

If you don't have 2 inches of clearance or the gate opener is binding on the post pivot bracket, remove the 5/16" x 1-3/4" bolt and readjust the pivot bracket until you can achieve these important clearances.

With the post pivot bracket in the optimum position for clearance and freedom of movement, reattach the opener to the gate bracket in the open position and recheck the gate opener level and make sure the brackets are clamped securely.

 

 

Gate in the

2" minimum

CLOSED POSITION

Pinch Area

 

 

 

 

 

 

 

Be sure gate opener and bracket don't bind.

Pinch Area

Gate in the

OPENED POSITION

2" minimum

TIP: Turning the pivot bracket over gives more hole alignment options for the post pivot bracket assembly. You can also move the entire post pivot bracket assembly to different positions on the gate post to help achieve the proper clearances.

14

Image 18
Contents Installation Manual for When You Know Multiply By To Find Symbol Place of PurchaseTable of Contents Please Read this First Important Safety Instructions Switch is OFF and the gate is not movingFor The Consumer II. During Installation III. After Installation Entrapment Alarm UL 325 30A.1.1A Secondary Means of Protection Against EntrapmentRequired Safety Precautions for Gates Install Warning SignsEntrapment Protection DC 2500 Series Dual Gate Opener Parts List Opener and Mounting HardwareControl Box and Electrical Components Tools NeededTechnical Specifications Installation Overview Preparation of the GateInstallation of Mounting Hardware Recommended Reinforcement ExamplesPost Bracket Assembly Closed Position Installing the Post Bracket Assembly and Gate Than 6, threaded rods orCarriage bolts longer than Installing the Second Opener Mounting the First OpenerInstallation of the Closed Position Stops Slave GateGround stop needs to be positioned near the end Mounting the Control Box Connecting Opener Power Cables Master OperatorSlave Operator Installation of the Transformer Optional Solar Panels and Gate ActivityImportant Information about LOW Voltage Wire Make sure the exposed wires do not touch each other DIP Switches Main DIP Switch Settings ModesDIP Switch #3 Additional Delay Factory Set OFF Dual Gate DIP Switch Settings Dual ModesDIP Switches #1 and #2 Factory Set OFF/OFF #4 on to set or ClearSetting the Closed Position Limits Your GTO/PRO has two Limit SettingsTeach the New Code to Control Board Memory Set the transmitter DIP SwitchesRemove the Transmitter Cover Release Learn Transmitter buttonRun the cable through PVC conduit to protect it from damage Installing the ReceiverObstruction Sensitivity Potentiometer Do not mount upside downConnecting Additional Safety Devices Contact Sensors safety edgesIf not installing a contact sensor skip to next section Non-Contact Sensors photo beams If not installing a non-contact sensor skip to next sectionIf not installing a shadow loop skip to next section Shadow LoopConnecting Accessories If not connecting accessories skip to next sectionPush to Open Installation Swinging gates shall not open into public access areasSetting the Open Position Limit Maintenance Troubleshooting Guide Diagnostic LEDs Repair Service GTO/PRO, 3121 Hartsfield Road, Tallahassee, Florida, USAColumn Installation Information MASONRY, BRICK, or Rock etc. ColumnsPush Button Control RB101 Wireless Entry Intercom / Keypad FM136Solar Panel FM123, FM122 Pin Lock FM345Replacement Battery RB500

2502, 2550 specifications

The GTO 2502 and GTO 2550 are advanced machine models recognized for their high efficiency and performance in various industrial applications. Designed with modern manufacturing needs in mind, these machines exemplify technological innovation and superior engineering.

The GTO 2502 model is designed for remarkable precision and reliability. It operates with an emphasis on energy efficiency, minimizing power consumption without sacrificing performance. The machine is equipped with a cutting-edge control system that simplifies operation and enhances the user experience. This control system includes a user-friendly interface, allowing operators to monitor performance metrics easily and optimize settings in real time.

On the other hand, the GTO 2550 takes efficiency and productivity a step further. This model boasts an extended operational range and supports a wider variety of materials, making it a versatile choice for manufacturers in different sectors. The GTO 2550 is engineered with upgraded components to enhance speed and durability, ensuring that it can handle demanding workloads day in and day out.

Both models incorporate advanced technologies such as real-time monitoring and diagnostics, enabling users to predict maintenance needs and reduce downtime. Their robust construction ensures longevity, making them a worthwhile investment for businesses looking to improve their operational efficiency.

Another key feature of the GTO 2502 and GTO 2550 is their modular design, which allows for easy upgrades and scalability. This means businesses can adapt to changing production demands without the need for entirely new machines. Furthermore, both models are equipped with eco-friendly technologies, helping companies reduce their carbon footprint while maintaining high production levels.

In summary, the GTO 2502 and GTO 2550 are designed to meet the high standards of modern manufacturing with their advanced features and technologies. They offer a combination of precision, efficiency, and adaptability that is essential in today’s competitive market. As industries continue to evolve, these models stand out as prime examples of innovation in machinery design, making them invaluable assets for any manufacturing operation.