GTO 2502, 2550 installation manual Make sure the exposed wires do not touch each other

Page 27

Step 6

Strip 1/2" of insulation from the ends of the low voltage wire. Attach these stripped ends to the transformer terminals.

A dab of household petroleum jelly on each terminal will help prevent corrosion.

Make sure the exposed wires do not touch each other!

Step 7

Plug the transformer into the electrical outlet.

(Use of a surge protector with the transformer is strongly recommended.)

HINT: Keep a few mothballs in the control box to discourage insects from entering it and damaging the control board.

Transformer

SURGE PROTECTOR

23

Image 27
Contents Installation Manual for Place of Purchase When You Know Multiply By To Find SymbolTable of Contents Please Read this First Switch is OFF and the gate is not moving Important Safety InstructionsFor The Consumer II. During Installation III. After Installation Secondary Means of Protection Against Entrapment Entrapment Alarm UL 325 30A.1.1ARequired Safety Precautions for Gates Install Warning SignsEntrapment Protection DC 2500 Series Opener and Mounting Hardware Dual Gate Opener Parts ListTools Needed Control Box and Electrical ComponentsTechnical Specifications Preparation of the Gate Installation OverviewRecommended Reinforcement Examples Installation of Mounting HardwarePost Bracket Assembly Closed Position Installing the Post Bracket Assembly and Gate Than 6, threaded rods orCarriage bolts longer than Mounting the First Opener Installing the Second OpenerSlave Gate Installation of the Closed Position StopsGround stop needs to be positioned near the end Mounting the Control Box Connecting Opener Power Cables Master OperatorSlave Operator Optional Solar Panels and Gate Activity Installation of the TransformerImportant Information about LOW Voltage Wire Make sure the exposed wires do not touch each other Main DIP Switch Settings Modes DIP Switches#4 on to set or Clear Dual Gate DIP Switch Settings Dual ModesDIP Switches #1 and #2 Factory Set OFF/OFF DIP Switch #3 Additional Delay Factory Set OFFYour GTO/PRO has two Limit Settings Setting the Closed Position LimitsRelease Learn Transmitter button Set the transmitter DIP SwitchesRemove the Transmitter Cover Teach the New Code to Control Board MemoryDo not mount upside down Installing the ReceiverObstruction Sensitivity Potentiometer Run the cable through PVC conduit to protect it from damageConnecting Additional Safety Devices Contact Sensors safety edgesIf not installing a contact sensor skip to next section Shadow Loop If not installing a non-contact sensor skip to next sectionIf not installing a shadow loop skip to next section Non-Contact Sensors photo beamsIf not connecting accessories skip to next section Connecting AccessoriesSwinging gates shall not open into public access areas Push to Open InstallationSetting the Open Position Limit Maintenance Troubleshooting Guide Diagnostic LEDs GTO/PRO, 3121 Hartsfield Road, Tallahassee, Florida, USA Repair ServiceMASONRY, BRICK, or Rock etc. Columns Column Installation InformationPin Lock FM345 Wireless Entry Intercom / Keypad FM136Solar Panel FM123, FM122 Push Button Control RB101Replacement Battery RB500

2502, 2550 specifications

The GTO 2502 and GTO 2550 are advanced machine models recognized for their high efficiency and performance in various industrial applications. Designed with modern manufacturing needs in mind, these machines exemplify technological innovation and superior engineering.

The GTO 2502 model is designed for remarkable precision and reliability. It operates with an emphasis on energy efficiency, minimizing power consumption without sacrificing performance. The machine is equipped with a cutting-edge control system that simplifies operation and enhances the user experience. This control system includes a user-friendly interface, allowing operators to monitor performance metrics easily and optimize settings in real time.

On the other hand, the GTO 2550 takes efficiency and productivity a step further. This model boasts an extended operational range and supports a wider variety of materials, making it a versatile choice for manufacturers in different sectors. The GTO 2550 is engineered with upgraded components to enhance speed and durability, ensuring that it can handle demanding workloads day in and day out.

Both models incorporate advanced technologies such as real-time monitoring and diagnostics, enabling users to predict maintenance needs and reduce downtime. Their robust construction ensures longevity, making them a worthwhile investment for businesses looking to improve their operational efficiency.

Another key feature of the GTO 2502 and GTO 2550 is their modular design, which allows for easy upgrades and scalability. This means businesses can adapt to changing production demands without the need for entirely new machines. Furthermore, both models are equipped with eco-friendly technologies, helping companies reduce their carbon footprint while maintaining high production levels.

In summary, the GTO 2502 and GTO 2550 are designed to meet the high standards of modern manufacturing with their advanced features and technologies. They offer a combination of precision, efficiency, and adaptability that is essential in today’s competitive market. As industries continue to evolve, these models stand out as prime examples of innovation in machinery design, making them invaluable assets for any manufacturing operation.