GTO 2550, 2502 installation manual When You Know Multiply By To Find Symbol, Place of Purchase

Page 2

The GTO/PRO SW-2502 Gate Opener is intended for use with vehicular swing gates. The opener can be used in Class I, Class II, Class III and Class IV applications.

VEHICULAR GATE OPENER CLASS CATEGORIES

Residential Vehicular Gate Opener-Class I: A vehicular gate opener (or system) intended for use in a home of one-to-four single family dwelling, or a garage or parking area associated therewith.

Commercial/General Access Vehicular Gate Opener-Class II: A vehicular gate opener (or system) intended for use in a commercial location or building such as a multifamily housing unit (five or more single family units), hotel, garages, retail store, or other building servicing the general public.

Industrial/Limited Access Vehicular Gate Opener–Class III: A vehicular gate opener (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public.

Restricted Access Vehicular Gate Opener–Class IV: A vehicular gate opener (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.

Conversion Chart

Converting Metric Units to English Equivalents

When You Know

Multiply By

To Find

Symbol

centimeters

0.3937

inches

in. (or ")

meters

3.2808

feet

ft. (or ')

kilograms

2.2046

pounds

lb. (or #)

Converting English Units to Metric Equivalents

When You Know

Multiply By

To Find

Symbol

inches

2.5400

centimeters

cm

feet

0.3048

meters

m

pounds

0.4535

kilograms

kg

Converting Temperature

deg. Celsius

(ºC x 1.8) + 32

deg. Fahrenheit

ºF

deg. Fahrenheit

(ºF-32) ÷ 1.8

deg. Celsius

ºC

FOR YOUR RECORDS

Please record the product serial number (located on the control box cover), and the date and place of purchase in the spaces provided below. Refer to this information when calling GTO for service or assistance with your automatic gate opener.

Serial Number ____________________ Date of Purchase ____________________

Place of Purchase ____________________

Remember to keep all receipts for proof of purchase.

Image 2
Contents Installation Manual for When You Know Multiply By To Find Symbol Place of PurchaseTable of Contents Please Read this First Important Safety Instructions Switch is OFF and the gate is not movingFor The Consumer II. During Installation III. After Installation Entrapment Alarm UL 325 30A.1.1A Secondary Means of Protection Against EntrapmentEntrapment Protection Required Safety Precautions for GatesInstall Warning Signs DC 2500 Series Dual Gate Opener Parts List Opener and Mounting HardwareControl Box and Electrical Components Tools NeededTechnical Specifications Installation Overview Preparation of the GateInstallation of Mounting Hardware Recommended Reinforcement ExamplesPost Bracket Assembly Closed Position Carriage bolts longer than Installing the Post Bracket Assembly and GateThan 6, threaded rods or Installing the Second Opener Mounting the First OpenerInstallation of the Closed Position Stops Slave GateGround stop needs to be positioned near the end Mounting the Control Box Slave Operator Connecting Opener Power CablesMaster Operator Installation of the Transformer Optional Solar Panels and Gate ActivityImportant Information about LOW Voltage Wire Make sure the exposed wires do not touch each other DIP Switches Main DIP Switch Settings ModesDIP Switch #3 Additional Delay Factory Set OFF Dual Gate DIP Switch Settings Dual ModesDIP Switches #1 and #2 Factory Set OFF/OFF #4 on to set or ClearSetting the Closed Position Limits Your GTO/PRO has two Limit SettingsTeach the New Code to Control Board Memory Set the transmitter DIP SwitchesRemove the Transmitter Cover Release Learn Transmitter buttonRun the cable through PVC conduit to protect it from damage Installing the ReceiverObstruction Sensitivity Potentiometer Do not mount upside downIf not installing a contact sensor skip to next section Connecting Additional Safety DevicesContact Sensors safety edges Non-Contact Sensors photo beams If not installing a non-contact sensor skip to next sectionIf not installing a shadow loop skip to next section Shadow LoopConnecting Accessories If not connecting accessories skip to next sectionPush to Open Installation Swinging gates shall not open into public access areasSetting the Open Position Limit Maintenance Troubleshooting Guide Diagnostic LEDs Repair Service GTO/PRO, 3121 Hartsfield Road, Tallahassee, Florida, USAColumn Installation Information MASONRY, BRICK, or Rock etc. ColumnsPush Button Control RB101 Wireless Entry Intercom / Keypad FM136Solar Panel FM123, FM122 Pin Lock FM345Replacement Battery RB500

2502, 2550 specifications

The GTO 2502 and GTO 2550 are advanced machine models recognized for their high efficiency and performance in various industrial applications. Designed with modern manufacturing needs in mind, these machines exemplify technological innovation and superior engineering.

The GTO 2502 model is designed for remarkable precision and reliability. It operates with an emphasis on energy efficiency, minimizing power consumption without sacrificing performance. The machine is equipped with a cutting-edge control system that simplifies operation and enhances the user experience. This control system includes a user-friendly interface, allowing operators to monitor performance metrics easily and optimize settings in real time.

On the other hand, the GTO 2550 takes efficiency and productivity a step further. This model boasts an extended operational range and supports a wider variety of materials, making it a versatile choice for manufacturers in different sectors. The GTO 2550 is engineered with upgraded components to enhance speed and durability, ensuring that it can handle demanding workloads day in and day out.

Both models incorporate advanced technologies such as real-time monitoring and diagnostics, enabling users to predict maintenance needs and reduce downtime. Their robust construction ensures longevity, making them a worthwhile investment for businesses looking to improve their operational efficiency.

Another key feature of the GTO 2502 and GTO 2550 is their modular design, which allows for easy upgrades and scalability. This means businesses can adapt to changing production demands without the need for entirely new machines. Furthermore, both models are equipped with eco-friendly technologies, helping companies reduce their carbon footprint while maintaining high production levels.

In summary, the GTO 2502 and GTO 2550 are designed to meet the high standards of modern manufacturing with their advanced features and technologies. They offer a combination of precision, efficiency, and adaptability that is essential in today’s competitive market. As industries continue to evolve, these models stand out as prime examples of innovation in machinery design, making them invaluable assets for any manufacturing operation.