Teledyne HPM-2002-OBE instruction manual DeviceNet TM, DeviceNet description

Page 23

3.4. DeviceNet TM

The HPM-2002-OBE with DeviceNet option is shown in figure below.

3.4.1.Overall Functional Description

The DeviceNet module consists of a power conversion/sensor transducer board, microprocessor board and a user interface option board. All communication is conducted via a 5-pin “Micro” style with center pin, male pin contacts. The module has passed the ODVA DeviceNet test and conforms to the vacuum/pressure gauge device profile; an Electronic Data Sheet (EDS) with limited features is also available upon request.

3.4.2.DeviceNet description

DeviceNet is a low-level network that provides connections between industrial devices (sensors and

actuators) and higher-level devices (controllers). Both power and high speed digital signaling are contained within the same cable. Controller Area Network (CAN) protocol is used to transfer commands and data across the bus. Up to 64 nodes are addressable per network.

Some of the user benefits of using DeviceNet are:

Reduced hardwiring and reduced start-up time through the use of standardized cables for the Trunk and Branch lines, in addition to standardized Taps for making physical interconnections.

Ease of integrating products from multiple vendors. More than 250 vendors produce DeviceNet products.

For more information, contact the Open DeviceNet Vendor Association (ODVA) at their web site. http://www.odva.org

HPM-2002-OBEVacuum Gauge

Page 23 of 39

Image 23
Contents Teledyne Hastings Manual Print History Table of Contents Troubleshooting HPM-2002-OBE Analog Output 4-20mA Module FeaturesModel 2002 Sensors HPM-2002-OBE Analog Output ModuleHPM-2002-OBE DeviceNet Module SpecificationsHPM-2002-OBE RS232/485 Output Module Quick Start Transducer InstallationOBE Module Installation Receiving InspectionPin Volt 20 mA RS232/485 Initial OperationHigh and Low Set Point Modes Analog OutputOverall Functional Description Cal Mode Run ModeAnalog Output GAS ModeGas Selection Table HPM-2002-OBEVacuum Gauge Analog Output 4-20mA Cal Mode Analog Output 4-20mA HPM-2002-OBEVacuum Gauge RS232/485 With Display Command SyntaxParamater Modification Commands Interrogation CommandsReset / Restore Commands Calibration Adjustment CommandsDevice Status Default RS232/485 SpecificationsModular Connector Pinout RS-485 Modular Connector Pinout R2-232 RJ-11 connector on left sideRun Mode DeviceNet description DeviceNet TMCalibration of the HPM-2002-OBE Zero Coefficient AdjustmentMidrange Coefficient Adjustment Atmosphere Coefficient AdjustmentTheory of Operation Vo = SPV+V1 Piezoresistive SensorHPM-2002-OBEVacuum Gauge Er = σεTh4-Ta4As Pirani SensorEt = Es + Er + Eg Es = K ∆T Am/LHPM-2002-OBEVacuum Gauge Dual Sensor Operation Eg = Kg ∆T As/∆xEg = arLt273/Th1/2Th-TaAgP HPM-2002-OBEVacuum Gauge RS485 Address Advanced Setup GuideData Bits/Parity Bits/Stop Bits Turnaround DelayRestore Eeprom Baud RateFrequently Asked Questions Why does my display read, Err1? Restore CalibrationRestore Factory Defaults Software ResetWhat are Err3, Err5, Err6 and Err7? Why does my display read, U.U?Why does my display read, U .? Why does my display read, . U?Non-Warranty Repair Policy Warranty Repair PolicyDiagrams and Drawings HPM-2002-OBEVacuum Gauge HPM-2002-OBEVacuum Gauge