Vidikron Vision 90t Home Theater Calibration Specifications, Industry-Standard Specifications

Page 66

Specifications

Table 7-1. Vision 90t/100t Specifications (continued)

Brightness and Contrast:

Cinema Standards Measurement System (CSMS)

 

Specifications

 

-

Brightness:

 

 

45.3 foot-Lamberts (fL) (Vision Model 90t);

 

 

78.5 foot-Lamberts (Vision Model 100t)

 

-

Contrast Ratio:

 

 

258:1 (Vision Model 90t);

 

 

228:1 (Vision Model 100t)

 

These measurements are taken from the projector in a controlled,

 

home theater environment. All measurements are made to

 

ANSI/NAPM IT7.228-1997 specifications using the Photo Research

 

PR-650 SpectraColorimeter and Minolta LS-100 Luminance Meter,

 

Video Essentials test DVD and a 1.3 gain, 72-inch wide screen. The

 

projector is calibrated to a color temperature of 6,500K and has a

 

minimum of 150 hours of usage.

 

The foot-Lambert (fL) is the unit of measurement used in commercial

 

movie theaters to express image brightness at the screen surface.

 

The Society of Motion Picture and Television Engineers (SMPTE)

 

specifies 16 fL as the target image brightness for film-based

 

projectors using an open gate (without film in the projector). More

 

importantly, today SMPTE specifies 12 fL as the target image

 

brightness in Digital Cinema theaters. The foot-Lambert

 

measurement is dependent on screen size, screen gain and projector

 

light output.

 

Home Theater Calibration Specifications

 

-

Light Output:

 

 

1120 ANSI Lumens (Vision Model 90t);

 

 

2631 ANSI Lumens (Vision Model 100t)

 

-

Contrast Ratio:

 

 

258:1 (Vision Model 90t);

 

 

228:1 (Vision Model 100t)

 

These specifications are obtained by calibrating the projector as

 

described above for CSMS measurements.

 

Industry-Standard Specifications

 

-

Light Output:

 

 

2250 ANSI Lumens (Vision Model 90t);

 

 

3500 ANSI Lumens (Vision Model 100t)

 

-

Contrast Ratio:

 

 

3000:1 (Vision Model 90t);

 

 

2000:1 (Vision Model 100t)

 

These are typical projector brightness and contrast specifications

 

found in most companies’ sales literature. Vidikron includes these

 

measurements in its literature to allow for direct comparison with

 

other manufacturers’ projectors. These measurements are typically

 

taken at 9,000K to 13,000K to get expected performance data when

 

the projector is used in professional, commercial and industrial

 

displays.

 

 

Lamp:

275 Watts

 

 

Estimated Lamp Life:

2000 hours

 

 

Inputs:

(1) Composite; (2) S-Video; (1) Component; (2) HD-R (Pr), G

 

(Y), B (Pb), H, V; (2) DVI w/HDCP

 

 

 

Control Options:

Built-in keypad

 

Discrete infrared remote

 

Serial commands via RS-232

56 Vidikron Vision Model 90t and Model 100t Owner’s Operating Manual

Image 66
Contents 90t/100t Page TWO Year Limited Warranty For Projectors, Video Processors and ControllersEffective Warranty Date Vidikron Safety Precautions 1Table of Contents Appendix A. Vision 90t/100t Color Gamut Adjustment Maintenance and TroubleshootingSpecifications Operation1List of Figures Page 1Introduction About This ManualThis Manual Using This Manual If you need Turn toDescription, Features and Benefits Optional Accessories 2Controls and Functions Vision 90t/100t at a GlanceComponent Video RCA connectors Vision 90t/100t Rear PanelHD1 / HD2 Analog BNCs Volt 750 mA Trigger Outputs Video 1 / S-VIDEOPower Input 100 to 240 VAC Menu ButtonVision 90t/100t Remote Control On / OFFMemory Preset Buttons ISF NT Night Cursor KeysCust HD 1 4 / HD 2 VideoComp Component DVI 1 6 / DVI 2Page 3Installation Remote ControlQuick Setup Installation OverviewStep Procedure For Details Refer to Installation Type Installation ConsiderationsProjector Installation Options Advantages ConsiderationsWith 126.9x54-inch Vision 90t/100t Lens Options and Throw RatiosThrow Ratio ScreenPerfectly-centered image that completely fills the screen PositionShift ExamplesFolded Optics Mounting the Vision Installing the OptionalCineWide Lens 90t/100tConnections to the Vision 90t/100t DVI Connections See FigureDigital DTV RGB Connections See Figure Digital DTV RGB ConnectionsAnalog Computer RGB Connections See Figure Analog RGB ConnectionsComposite/S-Video/Component Video Connections See Figure Composite, S-Video and Component Video ConnectionsConnection 10. RS-232 Control System Connection12. Connecting a 12-Volt Trigger Output to Other Equipment Power sourceTurning on the Power Adjusting the Picture Orientation4Operation Menus Lens AdjustmentsUsing the On-Screen FocusInput Source ISF PresetsService Aspect RatioAspect Ratio Main MenuInput Source Input Source Composite Video 1 S-Video Component SDAspect Ratio Settings DescriptionPicture RemotePicture Brightness Contrast Color Tint Sharpness Perform the adjustments in the order listed here Typical Pluge Pattern for Adjusting BrightnessGray Yellow Cyan Green Magenta Red Blue Gray Yellow Cyan Green Magenta Red Blue Input Position Input Position Left/Right Up/Down Width Height OverscanInformation ISF PresetsISF Presets ISF Night ISF Day Custom Save Factory Default Information Serial Number Hardware Firmware Date May 31Calibration Should be used by ISF-certified technicians onlyGain/Offset Refer to ISF Night Display Color, above Service Input Names Restore Composite Video Component SDDo not change the Type setting in this menu ADC Bandwidth Auto YPbPr Input Resolution HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUVAuto Operation Page 5Maintenance and Troubleshooting Lamp ReplacementLens Replacement Only trained, authorized Vidikron dealers should attempt toMaintenance and Troubleshooting Troubleshooting Tips Troubleshooting ChartSymptom Possible Causes Solution Serial Commands Serial Command SyntaxRS-232 Connection and Port Configuration 6Serial CommunicationsCommand Value Description Min/max Stored?Command Parameter Value Description Min/max Stored? PRESET?Iheight Bkgnd Page 7Specifications Vision 90t/100t SpecificationsVision 90t/100t Specifications Lamp Home Theater Calibration SpecificationsIndustry-Standard Specifications Estimated Lamp LifeWeight without lens Power RequirementsDimensions Limited WarrantyVision 90t/100t Dimensions Vision 90t/100t DimensionsAVision 90t/100t Color Gamut Adjustment Figure A-1. CIE 1931 Chromaticity DiagramSerial Connections Equipment Setup Required Hardware SoftwareTable A-1. Serial Commands for Gamut Adjustment Command Parameter Value Description Min/maxAdjusting the Gamut For blue on the command lineVision 90t/100t Color Gamut Adjustment Page Page RUMA-011085