TANDBERG T3 manual Bottom modules

Page 14

TANDBERG

 

Telepresence T3

bottom modules

Tip! The procedure outlined in this chapter suggests that you mount all three bottom modules before you mount the monitors on top of these modules.

As an alternative, you may prefer to mount each bottom module / monitor set completely before proceeding to the next bottom module / monitor.

Caution! Regardless of the method preferred, the cables between the DNAM modules and the monitors must be connected to the DNAM modules before you mount the monitors.

The cables are:

Cable 117850 to the left DNAM Cable 117852 to the center DNAM Cable 117856 to the right DNAM

4 × nut (b) M8

Note! Retain the DVI to HDMI cable between monitor and codec plus three power cables.

119078.01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12.08

1.Unpack the left system and take out the left Bottom module. Dismount the top screw on the right side in addition to the cable hatch cover.

2.The following cables must be disconnected and removed:

112083 Ethernet Cable

112980 Power Cable (main in)

115233 PC Connection Cable (Video/audio in)

117083 Main Speaker Cable (top of amplifier)

117087 D-sub Monitor Control Cable (USB-DSUB)

118315 External Microphone Cable

117084 Audio RCA Cable (Codec to amplifier).

3.Fasten by fastening 4 × nuts (b).

PAGE 14/58

Image 14
Contents Telepresence T3 Important information regarding room dimensions System assembly guide Telepresence T3Telepresence T3 Ceiling lightsTelepresence T3 Ceiling lightsCeiling light Light mounting detailsTelepresence T3 Light mounting detailsTable Floor structure Table Floor structure Do as follows10/58 11/58 12/58 Do not step on the plates Bottom modules Bottom modules 16/58 17/58 18/58 Table Column Assembly Floor cabling structure Cable bundling Structure in Floor From Kit No Drawing reference Art.NoTelepresence T3 Mounting the Column tray Mounting the Monitor AssembliesMounting the Monitor Assemblies25/58 Mounting the Camera RJ45 RJ45Mounting the Camera Cable Connection details System connectionsSystem cabling structure Cable bundling in the systems Cable bundling in the systems System cable connections left system System cable connections center system System cable connections right system Table Top Module Table Top Module 37/58 38/58 Table connections Keep signal and power cables apart Table cabling structureCable bundling in the table Cable RJ45 - RJ45 Cable HDMI - HDMICable bundling in the table 43/58 44/58 Table cable connections left system Table cable connections center system Table cable connections right system Table Connection notes Null-modem requirement Audio cable connectionsMounting Collaboration screensMounting Collaboration screens51/58 52/58 53/58 Mounting the TCU Mounting the TCU 56/58 57/58 58/58