Cable bundling in the table

 

Place following cables (use Art.No. For ID) according to numbers A–E on the figure ”Table Cabling Structure”

From Kit No.

118914

118048

Drawing reference

A

B

C

D

E

Art.No

117920

117921

117874

118555

118544

118545

118546

118547

118548

117857

Bundling description [OLD description]

Cable 9p DSUB – 9p DSUB

Cable 9p DSUB – 9p DSUB

Cable 9p DSUB – 9p DSUB

Cable Microdot – Microdot

Cable Microdot – Microdot

Cable Microdot – Microdot

Cable Microdot – Microdot

Cable Microdot – Microdot

Cable Microdot – Microdot

Cable DMS-59 – DVI split

From / to device

Table Quick Buttons L – Table Quick Buttons C Table Quick Buttons C – Table Quick Buttons R Telepresence Control Unit – Table Quick Buttons L

Mic L1 MicroDot to XLR adapter – Mic L1 Mic L2 MicroDot to XLR adapter – Mic L2 Mic C1 MicroDot to XLR adapter – Mic C1 Mic C2 MicroDot to XLR adapter – Mic C2 Mic R1 MicroDot to XLR adapter – Mic R1 Mic R2 MicroDot to XLR adapter – Mic R2

Telepresence Control Unit – Cable 111732

From / to device (Marking on older versions)

(SSTB Left – SSTB Main) (SSTB Main – SSTB Right) (Tec PC – SSTB Left)

(L1–Mic 1) (L2–Mic 2) (C1–Mic 3) (C2–Mic 4) (R1–Mic 5) (R2–Mic 6)

(Tec PC – Cable 111732)

119078.01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12.08

PAGE 44/58

Image 44
Contents Telepresence T3 Important information regarding room dimensions System assembly guide Telepresence T3Telepresence T3 Ceiling lightsTelepresence T3 Ceiling lightsCeiling light Light mounting detailsTelepresence T3 Light mounting detailsTable Floor structure Table Floor structure Do as follows10/58 11/58 12/58 Do not step on the plates Bottom modules Bottom modules 16/58 17/58 18/58 Table Column Assembly Floor cabling structure Cable bundling Structure in Floor From Kit No Drawing reference Art.NoTelepresence T3 Mounting the Column tray Mounting the Monitor AssembliesMounting the Monitor Assemblies25/58 Mounting the Camera RJ45 RJ45Mounting the Camera Cable Connection details System connectionsSystem cabling structure Cable bundling in the systems Cable bundling in the systems System cable connections left system System cable connections center system System cable connections right system Table Top Module Table Top Module 37/58 38/58 Table connections Keep signal and power cables apart Table cabling structureCable bundling in the table Cable RJ45 - RJ45 Cable HDMI - HDMICable bundling in the table 43/58 44/58 Table cable connections left system Table cable connections center system Table cable connections right system Table Connection notes Null-modem requirement Audio cable connectionsMounting Collaboration screensMounting Collaboration screens51/58 52/58 53/58 Mounting the TCU Mounting the TCU 56/58 57/58 58/58