4 Get-Function Listing

The PC can interrogate the LCD Monitor for specific information. The Get-Function packet format consists of 5 bytes which is similar to the Set-Function packet structure. Note that the “Value” byte is always = 00.

Get-Function description:

Length: Total bytes of message = 5 ASCII (35H), excluding “CR”

Command: Get-Function command code: One byte ASCII code

 

Value[1~3]:

Always = 000

 

 

 

 

Get-Function format from PC to LCD (ASCII)

 

 

 

 

Name

Length

Command

Value1

Value2

Value3

CR

 

Byte Count

5

1 Byte

0

0

0

00D

 

Bytes order

1

2

3

4

5

6

Monitor shall response to Get-Function with the following packet format:

LCD Monitor response packet format:

Name

Length

Value1

Value2

Value3

Value4

CR

Byte Count

5

1 Byte

1 Byte

1 Byte

1 Byte

00D

Bytes order

1

2

3

4

5

6

Response packet (to Get-Function):

Length: Total bytes of packet = 5 ASCII excluding “CR”

Exception: Total bytes for On-Hours = 6

Value[1-4]:Four ASCII codes: Value range is from 0000 ~ 9999

Exception: Value[1-5] for On-Hours

LCD Monitor will send “+” (02Bh), “CR” bytes to PC after receiving a valid command LCD Monitor will send “-” (02Dh), “CR” bytes to PC if the command is not valid

ViewSonic

CD3200

vi

Image 56
Contents ViewSonic Contents Customer Support Limited Warranty Following information is only for EU-member states For CanadaCE Conformity for European Countries Important Safety Instructions Declaration of RoHS Compliance Copyright Information Product disposal at end of product lifeViewSonic Safety and PrecautionsOperating Safety Repair Point of USE Environmental ConditionsConnecting Power SupplyPrecautions Service Performance CharacteristicsIntroduction Advantages in relation to CRT cathode ray tube displaysFurther features RS232 ProtocalIncluded Equipment Connecting External Devices InterfacePower indicator Controls and LocationTurn The LCD Display On Function KeyRemote Control Summary of Remote Control Buttons Selecting the primary signal sourceConnections & Applications How do I connect a Video device via Hdmi Hdmi ? How do I connect a PC via D-SUB ? How do I connect a video device via general cables? Using Volume Control Using MuteVolume Control Setting the Sleep TimerScart button PC/HD buttonVideo button Viewing the Menus and ON-SCREEN Displays Picture Setting Picture ModesHUE Picture SettingsColor Mode ViewSonic Sound Adjustment OFF modeEqualizer Voice POP Rock Jazz Manual ButtonMulti Mode FunctionViewSonic PIP Function Press the T button to select PIP Function optionSub Main Language PC Menu Brightness Darken and brighten picture brightnessColor Mode Mainpc Suboff Other Functions Troubleshooting Remote control does not workPicture is jittery PC Input Preset Timing Table Analog InputSpecifications Items SpecificationPanel Video InputFeature PowerDimension Audio InputCustomer Support Limited Warranty Table of content ViewSonicSet-Function Listing IntroductionDescription Length Command Value1 Value2 Value3 Length CommandExample Set Mute-ON command Ascii Set-Function descriptionPC Set-function command to LCD Monitor ID=C0h Command Value Range CommentsSet Function Code HexUpright Downleft Down Right Byte Count 00D Bytes order Get-Function ListingGet-Function description Response Range Comments PC Get-function command to LCD MonitorGet Function CD3200 Viii Name Length RCU-Code1 RCU-Code2 Byte Count 00D Bytes order Remote Control Pass-through modeMSB LSB Baseline RCU Pass-through codes HEXCD3200 RS-232 Command Table Set Function Command Value Range CommentsASPECT/EXIT See TableCD3200 Xiii CD3200 Xiv Pass Through Codes