ViewSonic VS11857 PC Get-function command to LCD Monitor, Get Function, Response Range Comments

Page 57

Table 4-1 outlines the Get-function command list that must be supported by the LCD Monitor

Table 4-1: PC Get-function command to LCD Monitor

Get Function

Command

Command

Response Range

Comments

 

Code (ASCII)

Code (Hex)

(Three ASCII bytes)

 

Get-Contrast

a

61

000 ~ 100

Gets Contrast value

Get-Brightness

b

62

000 ~ 100

Gets Brightness value

Get-Sharpness

c

63

000 ~ 100

Gets Sharpness value

Get-Color

d

64

000 ~ 100

Gets Color value

Get-Tint

e

65

-50 ~ +50

Gets Tint value

Get-Volume

f

66

000 ~ 100

Gets Volume value

Get-Mute

g

67

000: OFF (unmuted)

Gets Mute ON/OFF status

 

 

 

001: ON (muted)

 

Get-RCU

h

68

000: DISABLE

Gets RCU mode status

 

 

 

001: ENABLE

 

 

 

 

002: PASS THROUGH

 

Get-Key Pad

i

69

000: DISABLE

Gets Buttons ON/OFF status

 

 

 

001: ENABLE

 

Get-Input select

j

6A

000: VGA

Gets Input select status

 

 

 

001: DVI

 

 

 

 

002: COMPOSITE1

 

 

 

 

003: COMPOSITE2

 

 

 

 

004: COMPONENT1

 

 

 

 

005: COMPONENT2

 

 

 

 

006: S-Video1

 

 

 

 

007: S-Video2

 

 

 

 

008: HDMI1

 

 

 

 

009: HDMI2

 

 

 

 

010: HDMI3

 

 

 

 

011: HDMI4

 

 

 

 

012: HDMI5

 

 

 

 

 

 

Reserved

k

6B

 

Reserved for future expansion

Get-Power status

l

6C

000: STBY

Gets the status of the HDTV power.

 

 

 

001: ON

HDTV response:

 

 

 

 

000 = HDTV is in standby

 

 

 

 

001 = HDTV is ON

Get-On hours

m

6D

00000 ~ 99999

Get the ON hours of the HDTV. HDTV

 

 

 

 

shall accumulate the ON hours in

 

 

 

 

Flash memory. When it receives this

 

 

 

 

command it will response with the ON

 

 

 

 

hour value of 5 bytes.

Get-ACK

z

7A

000

This command is used to test the

 

 

 

 

communication link.

ViewSonic

CD3200

vii

Image 57
Contents ViewSonic Contents Customer Support Limited Warranty For Canada CE Conformity for European CountriesFollowing information is only for EU-member states Important Safety Instructions Declaration of RoHS Compliance Product disposal at end of product life Copyright InformationSafety and Precautions Operating SafetyViewSonic Repair Environmental Conditions Point of USEPower Supply ConnectingPrecautions Performance Characteristics ServiceIntroduction Advantages in relation to CRT cathode ray tube displaysRS232 Protocal Further featuresIncluded Equipment Interface Connecting External DevicesControls and Location Power indicatorTurn The LCD Display On Function KeyRemote Control Selecting the primary signal source Summary of Remote Control ButtonsConnections & Applications How do I connect a Video device via Hdmi Hdmi ? How do I connect a PC via D-SUB ? How do I connect a video device via general cables? Using Mute Using Volume ControlVolume Control Setting the Sleep TimerPC/HD button Video buttonScart button Viewing the Menus and ON-SCREEN Displays Picture Modes Picture SettingPicture Settings Color ModeHUE ViewSonic OFF mode Sound AdjustmentEqualizer Voice POP Rock Jazz Button ManualFunction Multi ModeViewSonic Press the T button to select PIP Function option PIP FunctionSub Main Language Brightness Darken and brighten picture brightness PC MenuColor Mode Mainpc Suboff Other Functions Remote control does not work TroubleshootingPicture is jittery Analog Input PC Input Preset Timing TableItems Specification SpecificationsPanel Video InputPower FeatureDimension Audio InputCustomer Support Limited Warranty ViewSonic Table of contentIntroduction DescriptionSet-Function Listing Length Command Length Command Value1 Value2 Value3Example Set Mute-ON command Ascii Set-Function descriptionCommand Value Range Comments PC Set-function command to LCD Monitor ID=C0hSet Function Code HexUpright Downleft Down Right Get-Function Listing Get-Function descriptionByte Count 00D Bytes order PC Get-function command to LCD Monitor Get FunctionResponse Range Comments CD3200 Viii Remote Control Pass-through mode MSB LSBName Length RCU-Code1 RCU-Code2 Byte Count 00D Bytes order HEX Baseline RCU Pass-through codesSet Function Command Value Range Comments CD3200 RS-232 Command TableSee Table ASPECT/EXITCD3200 Xiii CD3200 Xiv Pass Through Codes