HD Format: If for some reason the PlasmaWall does not properly detect the incoming signal format (color space) on the HD1 or HD2 inputs, specify it here (RGB or YUV). Otherwise, leave it set to Auto.

Triggers: Select Triggers from the Service menu to configure the 12-volt trigger outputs. You can assign one or more trigger outputs to each aspect ratio. Those triggers are then activated by selecting that aspect ratio.

Miscellaneous: Select Miscellaneous from the Service menu to set the following options:

Menu Mode: This is the manner in which the OSD menus appear and disappear when you press MENU. Choose one of the following:

0 = No transition; menus abruptly appear and disappear.

1 = Menus fade in and out.

2 = “Checkerboard” dissolve; menus appear and disappear in sections.

3 = “Window shade” effect; menus are drawn on a diagonal from top left to bottom right, and retract in the opposite direction.

Timeout - Short/Long: These settings control how long the OSD menus stay on screen. Select a time-out period of from 2 to 60 seconds.

Side Bar Color: This controls the color of the inactive image area. The range is from -100 (black) to 100 (white).

The inactive image area is on either side of the active image area when using the Standard 4:3 aspect ratio, and above and below the active image area when using the Letterbox aspect ratio.

Film Mode: Enable Film Mode to smooth out moving images from interlaced sources. In most cases, the PlasmaWall detects the proper “pull-down” rate and vertical frequency. However, if your source is jittery and/or tearing you may wish to enable Film Mode to ensure stable processing for that source.

Resolution: The DHD Controller defaults to an output resolution of 720p. When using the PlasmaWall with a computer or certain HD sources, you may want to force the DHD Controller to use a different output resolution. If so, select Resolution from the Service menu and choose one. Then, press ENTER to confirm.

System Reset: To reset ALL display settings (including image settings) back to their

factory defaults, choose System Reset from the Service menu. Select Confirm to continue or Back to cancel. This action is not undoable. Use it with caution!

Runco PlasmaWall Owner’s Operating Manual

43

Image 53
Contents PL-50XA PL-61DHD Page For Plasma Displays Three Year Limited WarrantyRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC DOC Compliance Notice Safety PrecautionsTable of Contents Specifications Maintenance and TroubleshootingOperation Serial CommunicationsList of Figures List of Figures About This Manual IntroductionIf you need Turn to Using This ManualKey Features and Benefits Description, Features and BenefitsOptional Accessories PlasmaWall at a Glance Controls and IndicatorsControls and Functions MENU/ENTER ConnectorsInput SELECT/EXIT AUDIO1, AUDIO2, AUDIO3 External Speaker OutputsDVD/HD2 DVD/HD3, DVD/HD4 HdmiRunco Icon DHD Controller Front PanelIR Sensor Vacuum Fluorescent DisplayLeft Button UP ButtonEnter Button Down ButtonComponent Video RCA connectors HD1 / HD2 Analog BNC connectorsDHD Controller Rear Panel DVI OUTComposite Video Input Main Power SwitchRS-232 Control Port Main AC FuseDHD Controller Remote Control DHD Controller Remote ControlEnter IR Output IndicatorLight MenuSVC CinemaISF DAY CustRemote Control InstallationOther surfaces Step Procedure For Details, refer to Quick SetupConsiderations InstallationMounting the PlasmaWall On a Wall or Table StandProlong operating life VentilationOther Considerations DHD Controller Connecting PlasmaWall to the DHD ControllerConnections to the PlasmaWall and DHD Controller RS-232 Connection from the DHD Controller to the PlasmaWall Connecting Source DTV Source Analog Computer RGB Connections See Figure Refer to Computer/Video Signal Compatibility on page 55 forComposite, S-Video and Component Video Connections Composite/S-Video/Component Video Connections See FigureConnection RS-232 ControllerCable Management 11. Installing the Cable ClampsInstallation Operation Turning on the PowerChanging the OSD Language Setting the PC Display PropertiesUsing the On-Screen Menus Service ISF PresetsInput Source Aspect RatioInput Source Main MenuAspect Ratio Input Source Composite Video 1 S-Video Component SDRemote Aspect Ratio Control Description Key Aspect Ratio SettingsPicture Brightness Contrast Color Tint Sharpness PictureTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Input Position Left/Right Up/Down Width Height Overscan Input PositionISF Presets ISF Night ISF Day Custom Save Factory Default ISF PresetsInformation CalibrationOperation Service Operation Operation Operation Symptom Possible Causes Solution Maintenance and TroubleshootingTroubleshooting Tips Computer/Video Signal Serial Communications Command Parameter Value Description Min/max Stored?Serial Communications Tint OWIDTH? PlasmaWall Specifications SpecificationsSpecifications are subject to change without notice End user except for plasma glass panelDHD Controller Specifications PlasmaWall Model PL-50XA Dimensions PlasmaWall DimensionsPlasmaWall Model PL-61DHD Dimensions Computer/Video Signal Compatibility Chart Computer/Video Signal CompatibilitySUN Page RUMA-010950