Sanyo TLS-9960 Setting the Tape Management Function, Tape MANAGE. setting is flashing

Page 15

TAPE MANAGEMENT FUNCTION

Setting the Tape Management Function

1Press the MENU button until the (TAPE MANAGEMENT) menu is displayed.

øThe “TAPE MANAGE.” setting is flashing.

@@@@<TAPE@MANAGEMENT>

öTAPE@MANAGE.@@@@N

öPROTECT@DAY@@@@@30

öREC@PASS@SET@@@@10

öGROUP@NO.@@@@@@@OFF

öOVERRIDE@@@@@@@@N

2Turn the SHUTTLE ring, to select the desired mode.

N. . . . . . The tape management function is not active.

Y. . . . . . . The tape management function is active.

When setting to “Y”, please continue with the settings below.

3Turn the JOG dial, until the “PROTECT DAY” setting is flashing.

4Turn the SHUTTLE ring, to select the desired number of days to protect the tape.

OFF . . . . The tape is not protected.

1-255 . . . Number of days to protect the tape (prevent over-recording), from the date of the last recording on the tape (or the last expected recording date (calculated using the tape length (T-120) and the recording speed).

NOTES:

œSince the last expected recording date is a calculated date (using the tape length (T-120) and the recording speed), it may be different from the actual last recording date, this due to other settings such as (alarm recordings, program timer recordings, holiday settings).

œWhen setting a program timer recording, the tape protection term is checked when the VCR is set to program timer recording stand-by mode.

œWhen a program timer recording is done, the data is updated when recording starts. Even if the recording is stopped before the programmed time, the original data (last expected recording date) will remain as calculated.

5Turn the JOG dial, until the “REC PASS SET” setting is flashing.

6Turn the SHUTTLE ring, to select the desired number of re-recording times.

OFF . . . . The number of re-recording times will not be checked.

1-100 . . . Maximum number of re-recording times.

(Refer to “Concerning the Number of Times Tapes can be Rerecorded on” on page 17.)

NOTES:

œThe data is updated at the beginning of the recording. Even if the recording is stopped before the end, the original data will remain unchanged.

œDuring Autorepeat recording, the re-recording times count will be updated every time the tape is rewound to the beginning. Autorepeat recording will proceed even if the count exceeds the “REC PASS SET” setting. If in the BUZZER section WARNING is set to “Y”, the buzzer is heard.

7Turn the JOG dial, until the “GROUP NO.” setting is flashing.

8Turn the SHUTTLE ring, to select the desired group number.

OFF . . . . The group number will not be checked.

1-15 . . . . Group number setting.

9Turn the JOG dial, until the “OVERRIDE” setting is flashing.

FTurn the SHUTTLE ring, to select the desired override mode.

Y . . . . . . . In case of a conflict that prevents recording, the next operation is executed. If recording is done, then the last recording date and the re-recording times count are updated.

N. . . . . . . In case of a conflict that prevents recording, the (TAPE MANAGEMENT) menu is displayed and the conflicting setting preventing recording will flash. The only possible action is to press the EJECT button, in order to eject the tape. (Refer to “Tape Management Conflict Display”.)

GPress the SEARCH/AUDIO ON button to save the settings.

NOTES:

œOnce the tape management data is recorded on tape, it cannot be changed.

œThe criteria (condition) for allowing recording will be based on the data recorded on the tape and not the settings in the (TAPE MANAGEMENT) menu.

14

English

Image 15 Contents
TLS-9960 Precautions Features AccessoryContents Front Panel OFF indicator Locations of Controls and IndicatorsOperation Indicators Operation Mode IndicatorRS485 B Back PanelPower Cord Installation About the memory resetConnections Reference pages are shown in square brackets Types of ON-SCREEN Displays and Display SequenceShuttle ring Using the JOG dial and Shuttle ringTypes of ON-SCREEN Displays and Display Sequence JOG dialLast 2 digits only are displayed Setting the Language and ClockSetting procedure is now completed Day of week is set automatically Date and time are displayed Changing the ON-SCREEN Display Selecting the On-screen Display Changing the Date/Time Display PositionVideo Cassette Tapes @@TIMING@@@@@@@@FIELD Setting the Action to Take When a Cassette is LoadedVideo Cassette Tapes Correct tape thread check functionIf tape management data is present on the tape Tape Management FunctionOperation If no tape management data is present on the tape@@@@TAPE@MANAGEMENT Setting the Tape Management FunctionTape MANAGE. setting is flashing Tape Management FunctionTape Management Conflict Display Conflict display sample@@@@@@PRESS@EJECT Normal Recording Before starting Recording Speed ModePause/Still indicator N blinks Normal RecordingConcerning the Number of Times Tapes can be Rerecorded on Changes to the Recording Speed Mode During RecordingAction to Take when the Video Signal Deteriorates Normal RecordingClog Detection Recording CheckAutorepeat Recording Setting the Mode at the End of the TapeRepeat indicator will light Autorepeat RecordingAlarm Recording Setting Alarm RecordingAlarm Reset in terminal Alarm RecordingAlarm Recording Counter Display Connections to the Alarm IN/OUT TerminalsAlarm Scan Alarm SearchRecording will not take place Program Timer RecordingDay of the week of the 8th line is flashing Program Timer RecordingTo Cancel all Program Timer Recordings Setting the HolidaysChanging a Program Timer Recording To Cancel a Program Timer RecordingThese portions will not be recorded Recording Using AN External Timer Input Series recording connections Series Recording SetupRepeat REC switch Series RecordingContinous Loop Recording Setup Series RecordingLoop recording connection example with 2 VCRs Single Image Recording Setup Alarm trigger while in single image recording modeSingle Image Recording Normal Playback Special Playback D Search 01 0000 will be displayed on screen Special PlaybackDay/Time Search Shuttle Ring OperationIs displayed on the digital display Setting the Security LockCounter will be reset to 0H 00M 00S Tape CounterSetting the Buzzer Clock AdjustmentSetting procedure on the first VCR is now completed Setting the RS-232C or RS-485 Data Transfer Speed DIP Switches SetupData Transfer Speed Setup RS-485 Connection Setting the RS-232C or RS-485 Data Transfer SpeedRS485 RJ-11 connector layout Connector a Connector B SignalTape END OUT Terminal Timer OUT TerminalTape END OUT Terminal Output Setting Output TerminalsOutput Terminals Series OUT/NON REC OUT terminal settingSW OUT Terminal Output Setting Field or Frame setting is flashingRemote Jack Remote control settingSwitching heads combination and azimuth display Heads Switching FunctionMaintenance Maintenance Maintenance TableMaintaining and Checking The Mechanism Troubleshooting Guide After a Power FailureSystem Down Specifications Weekdays 830 AM 500 PM Pacific Time Sanyo Industrial VCR WarrantyRC4Q/U