Sanyo DSR-3009P Recording Images in the Alarm Recording Area, Pre-alarm recording

Page 24

RECORDING IMAGES IN THE ALARM RECORDING AREA

Pre-alarm recording

Pre-alarm images

Monitored images

are recorded

are recorded

1 Setting the time

Press the MENU button to display the LANGUAGE/CLOCK SET menu, and set the date and time. After the setting has been made, press the EXIT/OSD button, the date and time appear in the operating display. (See page 44.)

MENU

<LANGUAGE/LANGUE/SPRACHE/IDIOMA>

 

 

 

 

ENGLISH

 

 

 

 

 

 

 

 

 

 

<CLOCK SET>

 

 

 

 

01-01-2002 TUE 00:00:00

 

 

 

<SUMMER TIME SET>

 

 

 

 

MODE

:

USE

 

 

 

 

 

WEEK

MONTH

TIME

 

 

 

ON

LST-SUN

03

02:00

 

 

 

OFF

LST-SUN

10

02:00

 

 

 

 

<EXT.CLOCK SET>

 

 

 

 

ADJUST.TIME

01:00

3 When an alarm is received, pre-alarm recording stops automatically and the alarm images are recorded.

The “PRE” disappears from the operating display, “ALARM” flashes and the ALARM indicator flashes.

01

REC ALARM 0001 REPEAT EN

10-06-02 09:30:15

ALARM

2 Set pre-alarm recording.

Press the MENU button to display the ALARM REC MODE SET menu. Set ALARM RECORDING to the desired alarm recording

setting (example: ENABLED). The setting for PRE-ALARM RECORDING will be set to “OFF”, so change it to “ON”. (See page 62.)

Press the EXIT/OSD button to return to the normal screen. “PRE” appears in the operating display, the ALARM indicator illuminates and pre-alarm recording starts (the REC mark does not appear).

The same monitored image as in the normal recording area is recorded repeatedly in the alarm recording area.

Recording onto the hard disk proceeds automatically (default setting) according to the following settings. The settings can be changed between long-period recording and high-quality recording in five steps. (See page 59.)

Hard disk recording areas: Normal recording area: 80% Alarm recording area: 19% Archive area: 1%

Picture quality: EN (Enhanced)

Recording speed: 8.33 FPS (81H)

REC/STOP

<ALARM REC MODE SET>

 

 

PICTURE QUALITY

:

SUPER FINE

 

 

 

 

AUDIO RECORDING

:

ON

 

 

ALARM RECORDING

:

ENABLED

 

 

ALARM INTERLEAVE

:

ONLY

 

 

PROGRAM GROUP

 

:

OFF

 

 

REC RATE: @

0.1FPS,

 

DURATION: 40SEC

 

 

PRE-ALARM RECORDING

:

ON

 

 

REC RATE:@

*** FPS,

 

DURATION: ***

=>

(01010 ALARMS CAN BE RECORDED )

 

 

ALARM TRIGGER

 

:

ALARM

ALARM

01

REC PRE

0000 REPEAT EN

10-05-02 18:10:25

English

23

Image 24
Contents English GB Deutsch DFrançais F Español EPrecaution LocationAvoiding Electrical Shock and Fire Contents Main Features Setting-up environmentAccessories Power cord Fixer power cord tie Ferrite core xHard disk protection Hard disk and cooling fan are consumablesPart Names Front panelPart Names Rear panel Connecting high image quality S-VHS video equipment Connecting to an AmplifierConnections Basic connections DSR-3016P modelWhen using the RS485 RJ-11 connector ConnectionsDigital series connections System control connectionsExternal alarm sensor setup Using as a monitor board during a motion sensor alarmConnecting a remote control circuit Sensor Alarm OUT connectorBUILT-IN Hard Disk Hard diskBUILT-IN Hard Disk Recording TimeBasic Normal Enhanced Fine Super Fine Operating display Setting the camera image to single-screen display Pausing imagesViewing Camera Images Viewing a single-screen imageViewing Camera Images Press camera select buttonPress camera select button 2 once more Viewing multiple-screen images Viewing images as 9-screen or 16-screen displaysViewing images as a 4-screen display Plus screen viewingViewing automatically switching images Automatically switching of the single-screen imagesExample To display images from camera 2 in the plus screen Automatically switching of the 4-screen images Automatically switching of the plus screen imageUsing two monitors for monitoring Displaying single-screen alarm images on monitorCanceling monitor 2 display Operating monitorRecording Images Normal Recording Area Normal recordingTimer recording Set the timerTimer recording stops when the set end time is reached Press the Timer buttonRecording Images in the Alarm Recording Area Alarm recordingSet alarm recording Suspicious person detectionRecording Images in the Alarm Recording Area Pre-alarm recordingSet pre-alarm recording Playing Back Recorded Images Playback operationsNormal playback Playing Back Recorded Images Playback in a single screenFast forward/fast rewind and reverse playback Zooming the image during playback Viewing still imagesFrame advance forward/reverse Playing back multiple-screen displays Playing back images as 9-screen or 16-screen displaysPlaying back images as a 4-screen display Alarm search See Searching for Recorded ImagesArchive area Preview displayAlarm search Press an Alarm button during playbackSearching for Recorded Images Turn the shuttle dial clockwiseAlarm thumbnail search Last nine alarm recording images recorded appearAlarm number of the currently-selected alarm image flashes Time/date searchArchive area search Example To search for 8 pm on 26 OctoberAlarm display flashes Motion detection searchMotion Detection Search screen appears Cursor moves to Channel Examples of recording area selectionCursor moves to Start Preview 10Use the jog dial to move the cursor to Preview Saving Copying Recorded Images Saving Copying Recorded Images Copying images to the hard disk archive areaCopy screen appears Archive Area display flashesCursor moves to Pictures CompactFlash recording area Formatting CompactFlash cardsShuttle dial clockwise Sanyo IMG00001 IMG00002 IMG00003Connecting to a drive Backing up to a DDS DAT drive InstalledRemovedInserting an Scsi card sold separately Model No. Super Store dat 24eListing Data Press Copy to Abort Copying images to a CD-R drive Menu Flow Chart and Menu Operations Menu Flow ChartMenu Flow Chart and Menu Operations Basic menu screen operationsOperations while a sub-menu screen is displayed Entering numbersSetting the language Initial SET MenuLANGUAGE/CLOCK SET menu Clock SET settings Setting summer timeInitial SET Menu EXT. Clock SET setting Timer settingsOperable functions during the period set By the timer To change camera images into automatic switching screensTo detect an alarm input in a camera image To hide camera images with a gray patternHoliday SET setting Example To set 17 November as a holidayAutomatic camera detection Initial SET sub-menu appears, and the cursor moves toRecording Setting Recording Setting Resetting each recording areaRecording Area SET menu Total Capacity displayArea Full Reset setting Follow the same procedure to make the setting forAlarm Recording Area Recording Conditions SET menuFollow the same procedure to make the setting OFF for Cursor moves to Total NumberCursor moves to Overwrite On flashesNormal REC Mode SET menu Normal REC Mode SET settingRelationship between Recording Area SET Repeat the above procedure to set cameras 5 to 16 to OFF Program REC SET menu1P-1 Select Individual Camera Rate FPSTimer SET menu Timer SET settingTimer reservations spanning more than 24 hours Flashes in the FPS columnOFF flashes in the SET column Cursor moves to MONOFF setting for Program flashes Cursor moves to the first line12Press the EXIT/OSD button Alarm REC Mode SET menu Alarm REC Mode SET settingSelects the recording method for alarm images = 30721 Alarms can be Recorded= 30200 Alarms can be Recorded Display example Alarm recording settings= 20480 Alarms can be Recorded Alarm images Alarm images are recorded Canceled Alternately Alarm canceledCamera 2 alarm canceled When 2 or more alarms occur Camera 4 alarmPre-alarm recording setting Cursor moves to the 2SEC setting for Duration and flashesCursor moves to Alarm Trigger OFF flashesAlarm trigger setting Display examples Alarm recording trigger settingsUsing the timer function for recording Set the alarm duration for each cameraExternal alarm detection Displayed and SA sensor alarm willSignal loss detection alarm Sensor built into this unit an intruderAlarm display settings Cursor moves to Alarm PriorityCursor moves to MON.2 Display Cursor moves to RetriggerMotion Sensor setting ExitSetting the alarm duration Setting is then complete11Press the EXIT/OSD button Resetting an alarm Alarm will then be canceledAlarm images will appear in a single-screen display SecondsGeneral Setting General Setting Display SET settingTitle setting Display SET menuVideo Loss SET setting Color level settingsBuzzer SET setting Auto will flashSecurity Lock SET setting Set User passwordOperating privileges and security lock All operations are locked. When the user Password is entered at the password entryCarried out. When the Administrator password Administrator password is entered, allRS-232C/RS-485 SET setting Security lock settingCanceling the security lock RS-232C SelectionHDD SET setting This completes the setting and the cursor moves to ControlRS-485 Selection Hard disk initializationAdding a hard disk Network connectionInserting the recommended LAN card Network SET setting Network SET sub-menu appears, and the cursor moves toCursor moves to Network Control Cursor moves to IP AddressPassword SET setting Example Set AB123456 as the ID1 passwordComputer operation Screen Setting Main menuScreen Setting Multi Screen settingRepeat steps 4 and 5 above to set 11 and 16 to Display examples Press the EXIT/OSD buttonSequence setting Normal flashesChanges to 16 and 16 changes to 1S flashes English1S flashes Cursor moves to Sequence SETSequence SET sub-menu appears Individual Interval SET sub-menu appearsSet both Timer a and Timer B Cursor moves to Main Monitor SETMask settings 15Press the EXIT/OSD button00 12 12 00 16 16 00 24 24 00 6 Example of mask display when timer is set Cursor moves to Mask SETPower FAILURE/USED Time Display About the sub-menuSaving Menu Setting Details Save menu settings onto a CompactFlash cardLoad menu settings from CompactFlash card Saving to a CompactFlash cardSaving Menu Setting Details Loading saved menu settingsIf copying the recording area settings Without PRE Alarm With PRE AlarmInterface Specifications Interface Specifications Command TableSpecifications Dimensions mm