Xantrex Technology XADC Mounting the Xadc and Panel when Connected, To install the AC loads

Page 23

Installation Instructions

AC Loads

To install the AC loads:

1.Route the AC load cables through the knockouts in the back of the panel.

2.Install breaker(s) for your AC loads. See the documentation for your breaker to determine how it installs.

3.Connect the hot lead (black) from each AC load to a breaker.

4.Connect the neutral lead (white) from each AC load to the rear AC bus on the panel, marked “AC Neutral Terminal”.

5.Connect the ground lead (green or bare) from each AC load to the front AC bus on the panel, marked “Equipment Grounding Terminal”.

Important: Make a note of which AC load has been connected to which breaker using the provided label on the panel to the side of the breakers. Use pencil in case the circuit is changed in the future.

AC input knockouts

Main AC input and AC loads ground connection to Equipment Grounding Terminal

Main AC input and AC loads neutral connection to AC Neutral Terminal

AC line connection to breaker 1 (30A panel) or breaker 4+5 (50A panel)

AC loads “hot” to any breaker except reserved AC line breaker

Figure 17 XADC AC Connections

Mounting the XADC and Panel when Connected

To mount the XADC and panel when connected:

1.Slide the complete unit into the mounting cutout.

2.Fasten the complete unit into the cutout and secure using 6 × #6 or #8 pan head, round head or washer head screws suitable for mounting the unit onto particleboard or wood.

3.Install the XADC faceplate and tighten the four screws (do not overtighten as this may cause stripping of the screw threads).

4.Install the DC fuse cover.

5.Install the panel faceplate and tighten the center screw (do not overtighten as this may cause stripping of the screw threads).

6.Close the hinged door.

975-0301-01-01

23

Image 23
Contents Xantrex AC to DC Converter Installation Instructions Conventions Used PurposeAudience Important Safety Instructions Precautions When Working With Batteries Explosive Gas PrecautionsFCC Information to the User Main Components InstallationXadc Internal Components AC/DC Distribution PanelAC/DC Distribution Panel Components AC/DC Distribution Panel and Xadc Internal Components Installation Tools and Materials Installation CodesChoosing a Location Installation ConfigurationsTo prepare the Xadc for installation Installing the Xadc stand-alone unitPreparing to Install To connect the DC Connecting the DC BatteryPreparing the Mounting Location for the Xadc To prepare the Xadc mounting locationTo connect the AC input Connecting the AC InputTo prepare the panel for installation Installing Xadc with the AC/DC Distribution PanelConfigurations To mount the Xadc using the mounting platesTo prepare the Xadc for connected installation To prepare the Xadc for remote installationTo connect the Xadc and panel together Connecting the Xadc and Panel TogetherConnection Types for AC and DC Connecting the DC to the PanelPreparing the Mounting Location for the Xadc and Panel DC PCB Removal To connect the panel to the Xadc DC side Connecting the Panel to the Xadc DC SideTo connect the panel to the Xadc AC side Connecting the Panel to the Xadc AC SideConnecting the AC to the Panel To mount the Xadc and panel when connected Mounting the Xadc and Panel when ConnectedTo install the AC loads To mount the Xadc and panel remotely DC Wire Size and Torque ValuesMounting the Xadc and Panel Remotely Electrical Performance Mechanical SpecificationsDate and Revision