Xantrex Technology XADC DC Wire Size and Torque Values, Mounting the Xadc and Panel Remotely

Page 24

Xantrex AC to DC Converter

Mounting the XADC and Panel Remotely

To mount the XADC and panel remotely:

1.Slide the panel into the mounting cutout (12 in. × 8 in. – 305 mm × 203 mm).

2.Fasten the panel to the mounting surface using 6 × #6 or #8 pan head, round head or washer head screws suitable for mounting the panel onto particleboard or wood.

3.Install the panel faceplate and tighten the center screw (do not overtighten as this may cause stripping of the screw threads).

4.Install the DC fuse cover.

5.Follow the instructions in “Mounting the XADC” on page 15 to mount the XADC.

DC Wire Size and Torque Values

Table 1 Torque Requirements

Connection

Torque Value

 

 

DC (+) Load Output Terminal

12 in-lbs (12-14 AWG)

DC (+) Battery Terminal Lug

30 in-lbs (2 AWG)

 

28 in-lbs (4-6 AWG)

 

25 in-lbs (8 AWG)

 

25 in-lbs (10-14 AWG)

DC (-) Ground Terminal Lug

30 in-lbs (2 AWG)

 

28 in-lbs (4-6 AWG)

 

25 in-lbs (8 AWG)

 

25 in-lbs (10-14 AWG)

DC (-) Ground Terminal Bus

35 in-lbs (4-6 AWG)

 

25 in-lbs (8 AWG)

 

20 in-lbs (10-14 AWG)

Line/Load Terminals

See Circuit Breaker

AC Neutral/Ground Terminal Bus(s)

35 in-lbs (4-6 AWG)

 

25 in-lbs (8 AWG)

 

20 in-lbs (10-14 AWG)

Ground Terminal

45 in-lbs (6 AWG)

 

40 in-lbs (8 AWG)

 

35 in-lbs (10-14 AWG)

 

 

Table 2 DC Wire Size (to battery bank)

 

Recommended minimum

Recommended maximum 2-way

Converter model

DC wire gauge

DC cable lengtha

XADC-40

8 AWG

20 ft (610 cm)

XADC-60

6 AWG

20 ft (610 cm)

XADC-80

4 AWG

20 ft (610 cm)

 

 

 

a.Run lengths over 20 ft. (610 cm) are not recommended. Using larger run lengths or smaller gauge wires than recom- mended will result in decreased charge/load output performance as well as additional heating and interference effects.

24

975-0301-01-01

Image 24
Contents Xantrex AC to DC Converter Installation Instructions Purpose AudienceConventions Used Important Safety Instructions Explosive Gas Precautions Precautions When Working With BatteriesFCC Information to the User Installation Main ComponentsAC/DC Distribution Panel Xadc Internal ComponentsAC/DC Distribution Panel Components AC/DC Distribution Panel and Xadc Internal Components Installation Codes Installation Tools and MaterialsInstallation Configurations Choosing a LocationInstalling the Xadc stand-alone unit Preparing to InstallTo prepare the Xadc for installation Connecting the DC Battery Preparing the Mounting Location for the XadcTo prepare the Xadc mounting location To connect the DCConnecting the AC Input To connect the AC inputInstalling Xadc with the AC/DC Distribution Panel ConfigurationsTo mount the Xadc using the mounting plates To prepare the panel for installationTo prepare the Xadc for remote installation To prepare the Xadc for connected installationConnecting the Xadc and Panel Together To connect the Xadc and panel togetherConnecting the DC to the Panel Preparing the Mounting Location for the Xadc and PanelConnection Types for AC and DC DC PCB Removal Connecting the Panel to the Xadc DC Side To connect the panel to the Xadc DC sideConnecting the Panel to the Xadc AC Side To connect the panel to the Xadc AC sideConnecting the AC to the Panel Mounting the Xadc and Panel when Connected To install the AC loadsTo mount the Xadc and panel when connected DC Wire Size and Torque Values Mounting the Xadc and Panel RemotelyTo mount the Xadc and panel remotely Mechanical Specifications Electrical PerformanceDate and Revision