Xantrex Technology XADC installation instructions FCC Information to the User

Page 5

Installation Instructions

12.Use the XADC for charging a lead-acid battery only. Do not use the XADC to charge nickel-cadmium or dry-cell batteries commonly used with home appliances and electronic equipment. These batteries may burst and cause injury to persons and damage to property.

13.Never attempt to charge a frozen battery. Charging a battery when its temperature is below 32 °F (0 °C) is inefficient and ineffective. If possible, warm the battery above 32 °F (0 °C) before charging.

FCC Information to the User

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction guide, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna

Increase the separation between the equipment and the receiver

Connect the equipment into an outlet on a circuit different from that which the receiver is connected

Consult the dealer where the XADC was purchased or an experienced radio/ TV technician for help

975-0301-01-01

5

Image 5
Contents Xantrex AC to DC Converter Installation Instructions Conventions Used PurposeAudience Important Safety Instructions Precautions When Working With Batteries Explosive Gas PrecautionsFCC Information to the User Main Components InstallationXadc Internal Components AC/DC Distribution PanelAC/DC Distribution Panel Components AC/DC Distribution Panel and Xadc Internal Components Installation Tools and Materials Installation CodesChoosing a Location Installation ConfigurationsTo prepare the Xadc for installation Installing the Xadc stand-alone unitPreparing to Install Preparing the Mounting Location for the Xadc Connecting the DC BatteryTo prepare the Xadc mounting location To connect the DCTo connect the AC input Connecting the AC InputConfigurations Installing Xadc with the AC/DC Distribution PanelTo mount the Xadc using the mounting plates To prepare the panel for installationTo prepare the Xadc for connected installation To prepare the Xadc for remote installationTo connect the Xadc and panel together Connecting the Xadc and Panel TogetherConnection Types for AC and DC Connecting the DC to the PanelPreparing the Mounting Location for the Xadc and Panel DC PCB Removal To connect the panel to the Xadc DC side Connecting the Panel to the Xadc DC SideTo connect the panel to the Xadc AC side Connecting the Panel to the Xadc AC SideConnecting the AC to the Panel To mount the Xadc and panel when connected Mounting the Xadc and Panel when ConnectedTo install the AC loads To mount the Xadc and panel remotely DC Wire Size and Torque ValuesMounting the Xadc and Panel Remotely Electrical Performance Mechanical SpecificationsDate and Revision