Xantrex Technology XADC AC/DC Distribution Panel, Xadc Internal Components

Page 7

Installation Instructions

5

 

 

4

 

 

3

 

6

2

 

7

1

 

POS

NEG

 

(+)

(-)

 

 

8

 

9

 

Figure 2

XADC Internal Components

 

Item

Description

 

1

AC wiring compartment hole

 

2

Black AC line cable

 

3

White AC neutral cable

 

4

Green AC ground cable

 

5

Grommet (supplied)

 

6

Strain relief (not supplied)

 

7

DC wiring compartment hole ½ in. - 3/8 in. trade size (with ¾ in. knockout)

8

DC fuses

 

9

DC positive (+) and negative (-) connection lugs

AC/DC Distribution Panel

The XADC may be pre-installed with an AC/DC Distribution Panel. The panel is available in two configurations which provides the approved wiring boxes for AC and DC connections:

30A (Part Number: 810-0030-00 XADC P30) – eight output breakers

50A (Part Number: 810-0050-00 XADC P50) – 10 output breakers

In each configuration there are also 11 unassigned DC fuses and four reserved fuses for the battery connections.

Figure 3 and Figure 5 show the main components of the XADC with AC/DC Distribution Panel.

Important: The XADC P30 and XADC P50 panels are not intended for use with rigid conduit systems.

975-0301-01-01

7

Image 7
Contents Xantrex AC to DC Converter Installation Instructions Audience PurposeConventions Used Important Safety Instructions Precautions When Working With Batteries Explosive Gas PrecautionsFCC Information to the User Main Components InstallationXadc Internal Components AC/DC Distribution PanelAC/DC Distribution Panel Components AC/DC Distribution Panel and Xadc Internal Components Installation Tools and Materials Installation CodesChoosing a Location Installation ConfigurationsPreparing to Install Installing the Xadc stand-alone unitTo prepare the Xadc for installation To connect the DC Connecting the DC BatteryPreparing the Mounting Location for the Xadc To prepare the Xadc mounting locationTo connect the AC input Connecting the AC InputTo prepare the panel for installation Installing Xadc with the AC/DC Distribution PanelConfigurations To mount the Xadc using the mounting platesTo prepare the Xadc for connected installation To prepare the Xadc for remote installationTo connect the Xadc and panel together Connecting the Xadc and Panel TogetherPreparing the Mounting Location for the Xadc and Panel Connecting the DC to the PanelConnection Types for AC and DC DC PCB Removal To connect the panel to the Xadc DC side Connecting the Panel to the Xadc DC SideTo connect the panel to the Xadc AC side Connecting the Panel to the Xadc AC SideConnecting the AC to the Panel To install the AC loads Mounting the Xadc and Panel when ConnectedTo mount the Xadc and panel when connected Mounting the Xadc and Panel Remotely DC Wire Size and Torque ValuesTo mount the Xadc and panel remotely Electrical Performance Mechanical SpecificationsDate and Revision