Xantrex Technology XADC Installation Codes, Installation Tools and Materials

Page 10

Xantrex AC to DC Converter

Installation Codes

Governing installation codes vary depending on the specific location and application of the installation. It is the installer’s responsibility to ensure that all applicable installation requirements are met. Some examples include the following:

The U.S. National Electrical Code (NEC)

The Canadian Electrical Code (CEC)

The U.S. Code of Federal Regulations (CFRs)

Canadian Standards Association (CSA) and the RV Industry Association (RVIA) for installations in RVs

Installation Tools and Materials

You will need the following items to install the XADC and panel:

#2 Phillips screwdriver for removal of AC and DC wiring compartment panels

Torque screwdriver (20 – 50 in-lb range) with flat head socket insert (optional robertson for AC and DC bus bars)

Pliers for strain relief installation

4 × #6 or #8 pan head, round head or washer head screws suitable for mounting the standalone XADC unit onto particleboard or wood and the equivalent screwdriver, or 6 × #6 or #8 pan head, round head or washer head screws suitable for mounting the attached XADC and AC/DC Distribution Panel installation and the equivalent screwdriver

All strain reliefs must be UL/CSA approved ½ in. or ¾ in. trade size strain relief:

One strain relief for DC wires for standalone XADC Four strain reliefs for separated mounting

Up to 14 additional strain reliefs as required for full AC and DC circuit population (dependent on wire sizing)

Four DC battery fuses and up to 11 additional DC load fuses

One breaker for installing the XADC, one AC breaker for installing the panel and up to six additional AC load breakers.

The following items are shipped with the XADC.

XADC converter

Xantrex AC to DC Converter Owner’s Manual (Part #: 975-0305-01-01)

Xantrex AC to DC Converter Installation Instructions (Part #: 975-0301-01-01) The following items are shipped with the AC/DC Distribution Panel.

AC/DC Distribution Panel

AC/DC Distribution Panel Safety Instructions sheet

10

975-0301-01-01

Image 10
Contents Xantrex AC to DC Converter Installation Instructions Audience PurposeConventions Used Important Safety Instructions Explosive Gas Precautions Precautions When Working With BatteriesFCC Information to the User Installation Main ComponentsAC/DC Distribution Panel Xadc Internal ComponentsAC/DC Distribution Panel Components AC/DC Distribution Panel and Xadc Internal Components Installation Codes Installation Tools and MaterialsInstallation Configurations Choosing a LocationPreparing to Install Installing the Xadc stand-alone unitTo prepare the Xadc for installation To prepare the Xadc mounting location Connecting the DC BatteryPreparing the Mounting Location for the Xadc To connect the DCConnecting the AC Input To connect the AC inputTo mount the Xadc using the mounting plates Installing Xadc with the AC/DC Distribution PanelConfigurations To prepare the panel for installationTo prepare the Xadc for remote installation To prepare the Xadc for connected installationConnecting the Xadc and Panel Together To connect the Xadc and panel togetherPreparing the Mounting Location for the Xadc and Panel Connecting the DC to the PanelConnection Types for AC and DC DC PCB Removal Connecting the Panel to the Xadc DC Side To connect the panel to the Xadc DC sideConnecting the Panel to the Xadc AC Side To connect the panel to the Xadc AC sideConnecting the AC to the Panel To install the AC loads Mounting the Xadc and Panel when ConnectedTo mount the Xadc and panel when connected Mounting the Xadc and Panel Remotely DC Wire Size and Torque ValuesTo mount the Xadc and panel remotely Mechanical Specifications Electrical PerformanceDate and Revision