These are some general ideas for setting up the URC1 for either a multiple user remote control, or a protected mode of operation. We will start from very first power up, all the way to leaving the URC1 to do it’s stuff. If you are interested in more details about the codes used refer to the the section on URC1 command codes.

1.Power up and test the URC1 as instructed in the initial testing section of the manual.

2.Hook up any of the peripherals that you may want to control such as lamps, radios, alarm systems etc. Make sure commons on circuits are connected properly to the URC1.

3.Enter in as a master user using *6. Use your tone generator to set the devices you want to exclude from the user, such as the alarm system. Use the control codes in the rear of the manual for instructions.

4.Set your initial values, check everything out for proper operation.

5.Set the user password, which is limited to three characters, and then the master password which is limited to four. Make sure and write these down. If you forget them, you have to disconnect the power and remove the battery to reset them.

6.Press *3 to tell the URC-1 that you are finished. At this point the URC-1 will blank it’s display, and wait for the password of a user or master to access it again. If a user is to access it, the items that you disabled by excluding them cannot be changed. Only the master can change them now.

URC1 • 19

Image 19
Contents Universal Remote Control Ramsey Transmitter Kits Ramsey ELECTRONICS, INC Table of ContentsIntroduction to the Ramsey URC1 URC1 Remote Control FeaturesHOW the URC1 Works Tips and Notes Ramsey Learn AS YOU Build Assembly StrategyHardware and Miscellaneous Ramsey URC1 Parts List SemiconductorsCapacitors ResistorsConstruction of the URC1 URC1 7805 Shiny side Topside PC Board Nut Screw URC1 Support wire Solder Fillet Main Displayboard URC1 Initial Testing Troubleshooting Tips Using Your URC1 URC1 URC1 Setting up the URC1 QH’ Charts and DiagramsCommon To set an output on or off To access the URC1To set the password URC1 Control CodesTo set a Control Pot To set a LevelTo vary the resistance up*CLevel ## or *2Level ## To set a TimerFor the master user to exclude devices from the user Special codes Resetting the entire unitDone Accessing the URC1 Testing the URC1Other tones URC # Expanding Notes Connector considerationsURC-1 Parts Layout Diagram Ramsey Kit Warranty Additional Suggested Items URC1 Universal Remote ControlEstimated Assembly Time Required Tools