To set timer1 on for 35 hours 12seconds, and off fore 10mS: *8101*00120035
Hook up some LEDs as shown with series resistors to the timer outputs, and then experiment a bit to see how this method works. Have patience as these codes take a little time to get used to.
For the master user to exclude devices from the user:
To exclude:
To include:
The access number is found on the chart with the pinouts of CON1. Since there is only 19 devices
The URC1 replies with a short then long tone to indicate “A” for acknowledge.
Example to turn timer 2 off from the user: *9181
Where 9 is the control code, 18 is the device number, and 1 disables the device from the user changing it. Notice of course that you must be entered as a master user to change these settings. Entering a 1 disables, and a 0 enables.
Special codes:
Resetting the entire unit:
Reset the display only:
*0000
Clear all:
*0CAL or *0252