Sennheiser FT-906B20, FT-905A, FT-902S35, FT-906A20, FT-902S15 Manipulation Function Display RX

Page 20

Receiver frequencies

4.1.2

DIVERSITY

A B

MENU

Y

N

SET

ESC

MANIPULATION

 

FUNCTION

 

DISPLAY (RX)

Chose option "RX-Freq." (chapter 4.1.1).

Depress

SET

to allow the receiver frequencies to be selected. The "M" on the display starts blinking.

24 MHz maximal

The EM 1046 RX receiver module can be configured as follows:

operation on max. 32 switchable frequencies or

variable adjustment of receiver frequencies (5 kHz grid) within 16 frequency ranges

The frequencies or frequency ranges selected must fall within the system's 24 MHz window. The configuration selected is stored in the EM 1046 RX receiver module by a personal computer via the service interface or by the remote computer. The configuration can be changed as often as desired.

Refer changes to the system configuration to your authorized Sennheiser distributor.

Example 1:

Variable adjustment within one frequency range (in the present case the total bandwidth of the system.

24 MHz maximal

24 MHz maximal

Example 2:

Variable adjustment within three frequency ranges. The frequencies between two adjacent frequency ranges cannot be used.

Example 3:

Seven selectable frequencies. The EM 1046 RX receiver modules come with this standard setting.

EM 203, Publ. 10/94 engl

20

Image 20
Contents Instruction for USE LED indicators Monitor headphones Introduction Important InformationTechnical overview Computer control Diversity Dynamics of the AF Input Signal HiDyn plusBlock diagram EM Possible transmitter Receiver combinations EM 203 receiver SK 2012 TV HiDyn plus SKM 4031 TV-HiDyn plus EM 1046/2.2 SK 50 UHF / SK 250 UHF SKM EM 203 receiver SER 20 transceiver Putting the EM 203 receiver To work Mains connection Start-up procedure Operating indications Nota BeneAvailable modules EM 1046 RX Receiver module Monitor EM 1046 RX receiver module Operating Elements on the EM 1046 RX Module Adjustment Receiver operation remains unaffectedManipulation Function Display RX Use keys Additional frequencies can be selected, if Subsequently RF signal level/deviation/batery condition From page 24, CH Nota Bene From page 26, CH From page 27, CH Display4.1.5 Text/frequency/battery condition Display indicates again To stop storage System configurations Identification data EM 1046-U-HRemote monitoring Transmitter battery Manipulation Function SET SET ESC LED indicators Monitor headphones Operating ElementsLED indicators Nota Bene Technical data Sennheiser Electronic KG