Panasonic manual Specifications, Model Number TY-TP42P6-S TY-TP50P6-S

Page 30

Specifications

 

 

 

 

Model Number

TY-TP42P6-S

 

 

TY-TP50P6-S

Type

 

Optic Touch Panel

 

Power Source

 

 

 

 

 

Voltage

 

DC + 5 V ± 10 %

 

Electric current

 

DC + 5 V Max 400 mA under

 

Supply system

from USB Bus Power (DC + 5 V Max 500 mA)

Touch Panel

 

 

 

 

 

Detection system

 

Infrared obstruction detection system

Panel window (W H)

928.5 mm 526.5 mm (36.55 ″ ⋅ 20.73 ″)

 

1,118 mm 632 mm (44.02 ″ ⋅ 24.88 ″)

Detection range (W H)

916 mm 516 mm (36.06 ″ ⋅ 20.31 ″)

 

1,100 mm 620 mm (43.31 ″ ⋅ 24.41 ″)

Effective detection range

Detection range + 1.0 mm (0.04 ″) at the top, bottom, left and right

Operating modes

Detection operation at input point, during initial movement and at end point 1

Resolution (W H)

1,833 1,033

1

 

 

2,201 1,241 1

Detection pitch

 

2.0 mm 2.0 mm (0.08 ″ ⋅ 0.08 ″)

Output system

 

Coordinate output

 

Number of optic elements (W H)

230 130 elements

 

276 156 elements

Optic element pitch (W H)

 

4.0 mm 4.0 mm (0.16 ″ ⋅ 0.16 ″)

Minimum stylus size (W H)

 

6.0 mm 6.0 mm (0.24 ″ ⋅ 0.24 ″)

Scan speed

Initial touch: 30 ms/frame max.;

during movement: 8 ms/frame max.

Touch pen

 

Infrared system

 

USB Interface (USB 1.1)

Terminal No. and Signal name

 

 

 

 

 

 

 

 

(TYPE B)

-DATA 2

 

1 Vcc

 

 

 

 

 

 

USB cable length: 2 m (6.56 ft)

 

2

1

 

 

3

4

 

 

+DATA 3

 

4 GND

Temperature

When operating: 0°C (32°F) to 50°C (122°F) (temperature gradient 25°C (77°F)/hr max.) 2

 

When not operating: -10°C (14°F) to 60°C (140°F) temperature gradient 25°C (77°F)/hr max.

 

 

 

Humidity

When operating: 20% to 85% (must be no condensation) 2

 

When not operating: 10% to 95%

 

 

 

 

Resistance to extraneous light

Lateral light: 2,000 lx MIN +20% (angle of incidence: 20°)

 

Frontal light: 10,000 lx MIN +20% (angle of incidence: 90°)

 

 

 

Panel form

Flat panel (Flat type)

 

 

 

External dimensions (W H T)

1,066 mm 634 mm 69 mm

1,256 mm 748 mm 69 mm

 

(41.97 ″ ⋅ 24.96 ″ ⋅ 2.72 ″)

(49.45 ″ ⋅ 29.45 ″ ⋅ 2.72 ″)

 

(Excluding mounting brackets)

(Excluding mounting brackets)

 

 

 

Weight

3.5 kg (7.7 lbs) Excluding mounting brackets

4.2 kg (9.3 lbs) Excluding mounting brackets

 

 

 

Extruded material

Aluminum

Notes:

1 When it is used with exclusive driver software.

2 This applies to the touch panel alone. When the panel is attached to a device such as a PDP, follow the environmental conditions for the device being used.

30

Image 30
Contents TY-TP50P6-S Operating InstructionsTable of Contents Precautions Setup location If something abnormal happens MaintenanceCleaning of the infrared transmissive area If the equipment starts to smoke or emit a strange odorAccessories Touch panel unitSetup procedure Attachment of the touch panel to the plasma display Attach the mounting bracket and conductivity tapeAttachment of the touch panel to the plasma display Installation of the USB driver Connection between the computer and plasma displayConnection with computer Installation of the USB Driver FunctionOperating environment Install USB Driver Installation of the USB Driver COM port number is confirmed with Device ManagerCase of Windows ME Installation of the USB Driver Case of Windows Installation of the USB Driver Case of Windows XP Installation of the USB Driver About the COM port Installation of the Touch Panel Driver Install Touch Panel DriverUninstallation of the Touch Panel Driver USB driver softwareCursor Position Fine Adjustment Setup programSetup of a basic Screen User Setting seeSetup program Setup of basic settingsTouch Pen ID indication Calibration Screen Double click Time User SettingTouch Pen Switch Double click AreaClick Mode TroubleShooting Before requesting repairsSpecifications Model Number TY-TP42P6-S TY-TP50P6-SExternal dimensions TY-TP42P6-S External dimensions TY-TP50P6-SCustomer’s Record