Panasonic TH-37PG9W, TH-42PG9W manual Options Adjustments

Page 36

Options Adjustments

Options

 

1/3

Off-timer function

Enable

 

Onscreen display

On

 

Initial INPUT

Off

 

Initial VOL level

Off

0

Maximum VOL level

Off

0

INPUT lock

Off

 

Studio W/B

Off

 

Advanced PIP

Off

 

Display size

Off

 

Item

Effect

Adjustments

Press button to adjust the volume when TV is turned on.

 

 

 

Off

On

Initial VOL

 

 

Off:

Sets normal volume.

 

 

On:

Sets your preferred volume.

level

Off

On

Notes:

 

 

 

 

 

When “Maximum VOL level” is “On”, the volume can only be adjusted between 0 and your maximum range.

You can hear the changed volume regardless of your volume setting before opening the options menu if you adjust the volume when “Initial VOL level” is “On” and cursor is on the menu.

Press button to adjust the maximum volume.

 

 

Off

On

 

 

Off:

Sets auto maximum volume.

Maximum VOL

 

On:

Sets your preferred maximum volume.

 

Notes:

 

level

Off On

 

• If the “Maximum VOL level” is set lower than the “Initial VOL level”, the “Initial VOL level”

 

 

 

 

automatically becomes the same as the “Maximum VOL level”.

The volume display can go up to 63 regardless of the settings.

You can hear the changed volume regardless of your volume setting before opening the options menu if you adjust the volume when “Maximum VOL level” is “On” and cursor is on the menu.

 

Off

PC

INPUT1

INPUT2

INPUT3

 

Locks the input switch operation.

 

 

Notes:

 

 

 

 

INPUT lock

• Only the adjusted signal is displayed (see page 13).

• Signal can be displayed when the Terminal board is installed.

 

Input switch can be used when this is set to “Off”.

In two screen display mode, if anything other than “Off” is set, the value will be fixed as the value input in the single screen display mode.

 

 

 

Off

 

 

On

 

 

 

Studio W/B

 

 

Off:

 

Nullify all the settings adjusted.

 

 

 

Off

On On:

 

Sets the colour temperature for TV studio.

 

 

 

 

 

Note:

Valid only when the low is set as colour temperature on screen adjustment.

 

 

 

Off:

 

Sets normal two screen display mode (see page 20).

 

 

 

On:

 

Sets Advanced PIP mode (see page 21).

Advanced PIP

Off

On

Notes:

 

 

 

 

 

 

 

 

 

• When “INPUT lock” is “On”, you cannot use all the two screen display functions.

 

 

 

 

 

 

,

 

buttons are unavailable during Advanced PIP mode operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjusts the image display size on screen.

 

 

 

 

 

 

Off:

 

Sets the normal image display size on screen.

 

 

 

On:

 

Sets the image display size approximately 95 % of the normal image display.

 

 

 

 

 

 

Off

On

Display size

Off

On

Notes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• This setting is valid only when the input signals are as follows; 525i, 525p, 625i, 625p, 750/60p,

 

 

 

 

 

 

750/50p, 1125/60i, 1125/50i, 1125/24sF, 1125/25p, 1125/24p, 1125/30p, 1250/50i (Component

 

 

 

Video, RGB, DVI, SDI, HDMI)

 

 

 

This setting is invalid when two screen display, digital zoom or Multi screen is selected.

When Display size is set to “On”, Pos. /Size adjustment cannot be used.

Refer to each board's operating instruction for DVI, SDI, HDMI's corresponding signals.

36

Image 36
Contents Operating Instructions EnglishModel No. TH-37PG9W Table of Contents Important Safety Notice Trademark CreditsSafety Precautions SetupDo not place any objects on top of the Plasma Display When using the Plasma Display If problems occur during useClean the power cable regularly to prevent it becoming dusty Electric shocks can result if this is not doneAccessories Accessories SupplyCheck that you have the accessories and items shown Connections AC cord fixingAC cord connection see Signal Names for Mini D-sub 15P Connector PC Input Terminals connectionCommand Serial Terminals connectionRS-232C Straight cable Communication parametersRGB signal R, G, B Example of input signal sourceComponent / RGB in connection Digital TV Set-Top-BoxPower On / Off Connecting the AC cord plug to the Plasma DisplayConnecting the plug to the Wall Outlet Selecting the input signal Initial selectionsSelecting the On-Screen Menu Language Swing up the door at PullBasic Controls Channel Adjustment OFF Timer buttonDigital Zoom see Press to access Standby on / OFF buttonOn-Screen Menu Displays Press to access From the unit Each adjust Screen To Signal screen for Digital see page 33To Set up Timer selection screen see page 26 To Present Time Setup seeMode Picture Explanation Aspect ControlsAdjusting Pos. / Size NormalisationIs pressed except button Press to change input signal Press to swap main picture and sub pictureAdvanced PIP Sub screen Main screenPicture Adjustments NormalDynamic CinemaAdvanced settings Sound Adjustment MuteDigital Zoom Display the Operation GuideSelect the area of the image to be enlarged Select the magnification required for the enlarged displayPresent Time Setup / Set up Timer Present Time SetupSet up Timer Display the Set up Timer screen Press to selectPower on Time / Power OFF Time Press to setupMode selection Start settingScreensaver For preventing after-images Reversal / Scroll selectionSetup of Screensaver Time Reduces screen after-imageSide Panel Adjustment This function may be applicable to the non-picture areaReduces power consumption Addition sign Selected InputComposite Setup for Input Signals PB, PR signals Component B, HD, VD signalsComponent / RGB-in select 3D Y/C Filter For Ntsc AV imagesColour system / Panasonic Auto Cinema reality / P-NRSetting RGB sync signal SyncFreq. kHz / V-Freq. Hz Displays the H Horizontal / V Vertical frequenciesOptions Adjustments Effect AdjustmentsOptions Adjustments Normalization Menu & EnterShipping condition Troubleshooting Plasma Display panelCOMPONENT/RGB/PC input signals Horizontal Vertical ComponentFrequency kHz Frequency Hz Component Specifications TH-37PG9W TH-42PG9WMemo Memo Customer’s Record