Main Menu (continued)
VIDEO CONFIG
|
|
|
| The underlined values are factory preset setting values. | |||||||
|
|
|
|
|
|
|
|
|
|
| |
Sub menu | Settings | Explanation |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |||
GAMMA | <STANDARD> | Used to select the gamma curve. |
|
| |||||||
SELECT*1*2 | <FILM> | <STANDARD>Standard mode <FILM>FILM mode | |||||||||
| <STDIO/PST> | <STDIO/PST>Color emphasis mode (in the gamma characteristic in | |||||||||
|
| which shades are valued more than the contrasts, it is suitable for | |||||||||
|
| use by the studio and the post production, etc. ) | |||||||||
|
| When FILM is selected, |
|
|
|
| mark is displayed in the top left of the screen. | ||||
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
FILM GAMMA*2 | <VARICAM> | Used to select the type of FILM gamma mode. | |||||||||
| <OTHER> | <VARICAM> | VARICAM use |
|
|
| |||||
|
| <OTHER> | When using other types than VARICAM | ||||||||
|
|
|
|
|
|
|
| ||||
COLOR TEMP. | Used to select the color temperature. |
| |||||||||
| <D93> | ||||||||||
| <D65> | <D93> Color temperature around 9300K |
| ||||||||
| <D56> | <D65> Color temperature around 6500K |
| ||||||||
| <VAR1> | <D56> Color temperature around 5600K |
| ||||||||
| <VAR2> | <VAR1> WB adjustment mode*4 | <VAR2> WB adjustment mode*4 | ||||||||
| <VAR3> | <VAR3> WB adjustment mode*4 |
|
| |||||||
SHARPNESS | <HIGH>*3 | Used to select the width of the sharpness edge. | |||||||||
MODE*2 | <LOW> | <HIGH> |
| Thin edge | <LOW> | Thick edge | |||||
SHARPNESS H*2 | Used to set the sharpness in the horizontal direction. | ||||||||||
|
| When adjusting, the item display moves to the lower part of the screen. | |||||||||
SHARPNESS V*2 | Used to set the sharpness in the vertical direction. | ||||||||||
|
| When adjusting, the item display moves to the lower part of the screen. | |||||||||
| <MODE2> | Used to select IP conversion mode. (J page 20 : About IP Mode) | |||||||||
| <MODE1> | <MODE2> | Field Interpolation | <MODE1> Frame Interpolation | |||||||
MONO*2 | <OFF> | Used to switch between color and monochrome (MONO). | |||||||||
| <ON> | <OFF> Color | <ON> | Monochrome | |||||||
|
| * When this is ON, the picture adjusting knob [CHROMA] setting is fixed at 0. | |||||||||
|
|
|
|
|
|
| |||||
ANAMO*2*7 | <OFF> | If an Anamo lens has been used on the camera, and input through | |||||||||
| <ON> | SDI 720/60P, 59.94P, the picture is resized to Anamo size | |||||||||
|
| magnification. (a vertically compressed signal can be amplified | |||||||||
|
| vertically and corrected when it is displayed.) | |||||||||
|
|
|
|
|
|
| |||||
SD ASPECT*2 | <4:3> | Used for setting the aspect ratio settings when using SD signal input. | |||||||||
| <16:9> | <4:3> | 4:3 display | <16:9> | 16:9 display | ||||||
SCAN*2 | <NORMAL> | Used to set | |||||||||
| <UNDER> | <NORMAL>Normal display | |||||||||
NOISE WIPE*2 | <OFF> | <OFF> This makes a fluid and smooth contrast obtainable. | |||||||||
| <ON> |
| This is especially effective for continuously changing the contrast of | ||||||||
|
|
| the source signal or CG signal when the S/N is very high. | ||||||||
|
| <ON> | Noise reduction mode. Depending on the camera, this mode can | ||||||||
|
|
| be especially effective for dark scenes. We recommend leaving | ||||||||
|
|
| this setting “ON” under normal conditions. | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
*1 During 2 screen display, the changes are not reflected in the still image of the main window.
*2 When
1)VIDEO system input line (VIDEO,Y/C)(Factory settings are SHARPNESS MODE : LOW, SHARPNESS H/V : 0)
2)any other input line’s HD (Factory settings are SHARPNESS MODE : HIGH, SHARPNESS H/V : 0)
3)any other input line’s SD (Factory settings are SHARPNESS MODE : LOW, SHARPNESS H/V : 0)
and the setting values for the selected input signal from within this group is displayed. The adjustment status is displayed in the bottom right when selected.
*4 When “VAR1”, “VAR2” or “VAR3” is selected, the monitor switches to WB adjustment mode (J page 20).
*5 When selecting
1) Push [ENTER] (USER changes to blue). | 2) Select |
*6 When using “SUB WINDOW” function (J page 24), |
|
1)change the setting after releasing “SUB WINDOW” function.
2)we recommand “MODE2” for the image with a fast movement. *7 During Anamo size display, “SCAN” change is not reflected.