3. Setup
The table below lists the default settings.
Switch | Signal | Description |
XP1 | BLACK | Internally generated signal, black |
XP2 | INPUT1 | External video input 1: SDI or analog HD component |
XP3 | INPUT2 | External video input 2: SDI or analog HD component |
XP4 | INPUT3 | External video input 3: SDI or analog HD component |
XP5 | INPUT4 | External video input 4: SDI or analog HD component |
XP6 | INPUT5 | External video input 5: SDI or analog HD component |
XP7 | DVIIN | External video input 6: |
3-4-2. Setting the crosspoint switching
The timing at which the crosspoints are to be switched can be set.
ANY: The crosspoints are switched in the nearest field. This is suited to live applications.
F1: The crosspoints are switched in field 1. This is suited to editing applications.
F2: The crosspoints are switched in field 2. This is suited to editing applications.
Press the [FUNC] switch to light its indicator, and then press the [XPT] switch to display the XPT menu. Turn [F1] to display the XPTSW menu.
Turn [F2], and select the switching timing using the TIMG item.
XPTSW
3/3
TIMG
ANY
F1
F2