Pelco C2900M-B(1/03 manual Firmware Upload

Page 73

FIRMWARE UPLOAD

Units have flash EPROMs for firmware upgrades in the field. These upgrades can be done directly from the web browser.

Do the following to upload firmware using the web browser:

1.Obtain the latest PelcoNet NET104A Transmission System firmware from Pelco (http://www.pelco.com).

2.Use the browser to select the General Settings configuration page of your unit.

3.Use the Browse button in the Firmware update field to select the correct new firmware file.

4.Click the Upload button.

5.After about 30 seconds you should get a feedback message from the connected unit.

6.The message Òupload complete Ð WAITÓ confirms the correct upload of the new firmware, which is now being installed. The alarm input LEDs will flash back and forth between red and green to indicate installation.

WARNING: Do not disconnect power to the unit for any reason while firmware is being in- stalled. Disrupting the cycle will damage the flash EPROM. If this occurs, you will have to return the unit for repair.

When all the alarm input LEDs turn green, reprogramming is complete and the unit cycles power.

7.If you try to upload an invalid firmware file, you will get the message ÒUpload Failed.Ó

8.If you revisit the General Settings configuration page after the firmware is uploaded successfully, you will see the message ÒNew Firmware Installed.Ó

C2900M-B (1/03)

73

Image 73
Contents Transmission Via Networks International Tel 1-559/292-1981 Fax 1-559/348-1120 D E N D U MContents Typical Session Command Reference Connection Scenario List of Illustrations List of Tables Unpacking Instructions Important Safeguards and WarningsTransmitter Instructions for the Network AdministratorMinimum Requirements BrowserHOW do LANs and WANs WORK? What is the Pelconet NET104A Transmission SYSTEM?Remember that the IP address must be unique on the network Description OverviewSoftware Version Package ContentsModels Front Panel LEDs Front Panel LEDsRear Panel Connectors Rear Panel ConnectorsConnecting a Camera or Monitor Quick Installation GuideConnecting to the LAN Port Connecting Additional ItemsConnect any additional items, such as alarms, audio, etc Key = Transmitter = AC power plug adapter Connecting PowerSelecting AN IP Address for Your Network What is NEXT?Displaying Remote Video on a WEB Browser Typical ApplicationsPelcoNet NET104A Home Displaying Video VIA a TRANSMITTER-TO-RECEIVER Connection Following explains a box-to-box connection LAN Box-To-Box Connection Transmitter, Receiver, Spectra Diagrams of Typical ApplicationsLAN Browser-To-Box Connection Transmitter, Browser, Spectra Video Browser Data Genex Spectra WAN Box-To-Box Connection Transmitter, Receiver, Spectra WAN Browser-To-Box Connection Transmitter, Browser, Spectra Video Data Genex Browser Spectra Connecting Video Sources or Displays Hardware InstallationConnecting Audio Equipment Up to four video sources can be connected to the NET104AUse As Control Terminal Port Connecting Data TerminalsUse As Transparent Data Port Data Port Pin Assignments In RS-232 ModePush the terminal block back on to the plug-in base Connecting External SensorsNET 104A Connecting to a LAN ConfigurationConfiguration Using a Terminal Program Highlight Accessories. Click HyperTerminalSet the gateway IP address a set the alarm IP Connect to alarm IPTypical Session PelcoNet tries to call the alarm IP host Command ReferenceCmd Description PelcoNet disconnectsToggles the Dhcp Dynamic Host Configuration Protocol on/off Closes the connection from the connecting IP addressDisplay the unitÕs MAC address Display version informationWeb Server Concept Configuration Using a WEB BrowserNET-Manager PelcoNet NET104A Menu Tree Quick Guide To The Menu StructurePelcoNet NET104A Home C2900M-B 1/03 General Settings Configuration General ConfigurationDefault Description Setting Upload the firmware and install it on the system Update0.0 Equipment on your networkScreen For Entering The Password Network Settings Configuration Video port Video when using the multicasting protocol Five simultaneous live video connections Enable OffOff Base Port 25000Video Settings Configuration Video Settings ConfigurationConfiguration Default Setting Description Video Priority ActiveX Adjusted valueExample, the Internet 1000Password IP address Images will be stored Login namePartially obscure Time Stamping Time stamping OffAudio Settings Configuration Audio Settings ConfigurationDefault Setting Description Alarm Settings Configuration Alarm Settings ConfigurationTriggers the alarm Video alarm OffMotion alarm Off Select on to trigger an alarm in the eventMotion detection triggers an alarm Required to trigger an alarmAlarm indicator box lets you set a AlarmsAlarm input Alarm input OffMaster Alarm Off Enable all other alarmsConnect Live video in case of an alarmRelay output can open the door remotely Live video 0.0Switched on at the end of the alarm Bistable Select an operating mode for each relay¥ Motion alarm Triggering by motion alarm ¥ Remote input pin Triggering by switchingInterface Settings Configuration Interface Settings ConfigurationTo program the unit through HyperTerminal Com ports TerminalHyperTerminal Baudrate 19200ActiveX Dialog Box Live Video and Server Push Video PagesClick Control to access the Device Controls Accessing These PagesWEB Browser Control Pages Controlling the Display Matrix Control Live VIDEO/SERVER Push page Contents Genex Live VIDEO/SERVER Push page Contents C2900M-B 1/03 Spectra Live VIDEO/SERVER Push page Contents Esprit Live VIDEO/SERVER Push page Contents Automatic Connection Feature Advanced FeaturesVideo Motion Detection Feature Record and Play Back the Display on a PC Alarm Notification by E-MAILPlaying Back The Recording Recording The DisplayClick a or button. Click the button to resume playback Clicking the buttonFirmware Upload Green Power LED TroubleshootingBasic Functioning Com LED Ethernet LEDsOutput LEDs Input LEDsVideo LEDs Troubleshooting a TCP/IP Network Using a Ping UtilityTerminal Program Troubleshooting the Video Connection Troubleshooting Connection ProblemsTest Between NET104A And NET101R-A Testing the Audio ConnectionTest Between NET104A And PC Specifications Dimensions Storage Temperature 4to 140F -20to 60C Storage HumidityLED Displays 41 to 104F 5 to 40CGlossary MAC Address Media Access Control/hardware address Internet Service ProviderSee Internet Protocol IP AddressSee Wide Area Network Unshielded Twisted PairWide Area Network Appendix a Connecting Pelconet NET104A to Various Components Refer to and the instructions that follow Connection ScenarioC2900M-B 1/03 KBD4000 Connected to a Multiplexer Refer to and the instructions that followC2900M-B 1/03 CM9760KBD Connected to a CM9760-CC1 Controller C2900M-B 1/03 Create a cable using the above diagram Connecting PelcoNet to Genex Using the COM in RS-232 PortUsing PelcoNet with CM9505 to Provide Remote Control Connecting a Pelconet Receiver to a System CM9502Using PelcoNet with CM9502 to Provide Connecting Pelconet to a CM9502 Ascii Serial PortC2900M-B 1/03 CM6700-MXB Connecting Pelconet to a CM6700 Ascii PortPelconet CM9760-DT Setup Using PelcoNet to Transmit Data and Video Between 9760 Nodes Using PelcoNet to Receive Data and Video Between 9760 Nodes Pelco recommends using Port ¥ Port 2 defaults to Ascii and RS-232Pelconet CM6800 Ascii Setup Using PelcoNet with CM6800 to Provide Remote ControlMenu Screen Manager Screen102 C2900M-B 1/03 Setup To Provide Remote ControlPart Can I view PelcoNet over the Internet? What TCP/IP ports does PelcoNet use?Can I enlarge the picture size in the browser? What software does PelcoNet require?106 C2900M-B 1/03 How much bandwidth does PelcoNet use? How do I program PelcoNet with HyperTerminal?Can I use PelcoNet with a DSL or cable connection? Index Idle state 59 Input level IP address set command 35 IP address settingVideo quality 49 Video resolution Version numbers for hardware/software 42 Video alarmVideo bandwidth ActiveX 50 Video priority Select area 55 Send emailWarranty and Return Information ISO9001