CONNECTING EXTERNAL SENSORS

The unit has four alarm inputs that let you connect external signaling devices, like door contacts or motion detectors. If configured accordingly, an alarm trigger can, for example, set up an automatic connection between NET104A and the remote station. You can connect switches or contacts directly without a separate power supply.

Connection INPUT 5 is a master alarm. This connection lets you activate or bar (for example, by means of a key-operated switch) all the alarm triggers.

NOTE: Do not connect the ground terminals to earth ground. External switching voltage must not exceed 12 VDC.

The four alarm inputs are optically isolated from the other components of the NET104A via optocouplers and require a voltage of 5-12 VDC for switching.

Do the following to connect external sensors. Refer to Figure 21.

NET 104A

VIDEO1

VIDEO2

VIDEO3

VIDEO4

AUDIO

ALARM

 

 

 

 

ALARM

 

 

 

 

INPUTS

 

 

 

 

OUTPUTS

COM

 

 

 

 

 

 

 

5

1

2

3

4

+5V

1

2

3

4

 

 

POWER

 

 

 

IN

OUT

 

+

+

+

+

 

 

 

 

 

 

 

 

 

 

75 OHM ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

 

 

 

 

GND

 

 

 

 

RS232/422/485

10/100 BASE-T

12V~0.8A

ACTIVE

HIGH

+5V

ACTIVE

LOW +5V

ALARM

 

 

 

ALARM

 

INPUTS

 

 

OUTPUTS

5

1

2

3

4 +5V

1

2

3

4

OUT

+

+

+

+

 

 

 

 

GNDGND

Figure 21. Alarm Connections

1.Pull the terminal block INPUTS from its plug-in base.

2.Attach the conductors to the alarm input and ground terminals. (Push a small screwdriver or similar instrument into the square opening. This opens the circular opening. Insert the wire into the circular opening, and then remove the screwdriver.)

3.Push the terminal block back on to the plug-in base.

C2900M-B (1/03)

33

Image 33
Contents Transmission Via Networks International Tel 1-559/292-1981 Fax 1-559/348-1120 D E N D U MContents Typical Session Command Reference Connection Scenario List of Illustrations List of Tables Unpacking Instructions Important Safeguards and WarningsTransmitter Instructions for the Network AdministratorMinimum Requirements BrowserWhat is the Pelconet NET104A Transmission SYSTEM? HOW do LANs and WANs WORK?Remember that the IP address must be unique on the network Description OverviewPackage Contents Software VersionModels Front Panel LEDs Front Panel LEDsRear Panel Connectors Rear Panel ConnectorsConnecting a Camera or Monitor Quick Installation GuideConnecting Additional Items Connecting to the LAN PortConnect any additional items, such as alarms, audio, etc Key = Transmitter = AC power plug adapter Connecting PowerSelecting AN IP Address for Your Network What is NEXT?Displaying Remote Video on a WEB Browser Typical ApplicationsPelcoNet NET104A Home Displaying Video VIA a TRANSMITTER-TO-RECEIVER Connection Following explains a box-to-box connection LAN Box-To-Box Connection Transmitter, Receiver, Spectra Diagrams of Typical ApplicationsLAN Browser-To-Box Connection Transmitter, Browser, Spectra Video Browser Data Genex Spectra WAN Box-To-Box Connection Transmitter, Receiver, Spectra WAN Browser-To-Box Connection Transmitter, Browser, Spectra Video Data Genex Browser Spectra Connecting Video Sources or Displays Hardware Installation Connecting Audio Equipment Up to four video sources can be connected to the NET104AUse As Control Terminal Port Connecting Data TerminalsUse As Transparent Data Port Data Port Pin Assignments In RS-232 ModeConnecting External Sensors Push the terminal block back on to the plug-in baseNET 104A Connecting to a LAN ConfigurationConfiguration Using a Terminal Program Highlight Accessories. Click HyperTerminalConnect to alarm IP Set the gateway IP address a set the alarm IPTypical Session PelcoNet tries to call the alarm IP host Command ReferenceCmd Description PelcoNet disconnectsToggles the Dhcp Dynamic Host Configuration Protocol on/off Closes the connection from the connecting IP addressDisplay the unitÕs MAC address Display version informationConfiguration Using a WEB Browser Web Server ConceptNET-Manager PelcoNet NET104A Menu Tree Quick Guide To The Menu StructurePelcoNet NET104A Home C2900M-B 1/03 General Settings Configuration General ConfigurationDefault Description Setting Upload the firmware and install it on the system Update0.0 Equipment on your networkScreen For Entering The Password Network Settings Configuration Video port Video when using the multicasting protocol Five simultaneous live video connections Enable OffOff Base Port 25000Video Settings Configuration Video Settings ConfigurationConfiguration Default Setting Description Video Priority ActiveX Adjusted valueExample, the Internet 1000Password IP address Images will be stored Login namePartially obscure Time Stamping Time stamping OffAudio Settings Configuration Audio Settings ConfigurationDefault Setting Description Alarm Settings Configuration Alarm Settings ConfigurationTriggers the alarm Video alarm OffMotion alarm Off Select on to trigger an alarm in the eventMotion detection triggers an alarm Required to trigger an alarmAlarm indicator box lets you set a AlarmsAlarm input Alarm input OffMaster Alarm Off Enable all other alarmsConnect Live video in case of an alarmRelay output can open the door remotely Live video 0.0Switched on at the end of the alarm Bistable Select an operating mode for each relay¥ Motion alarm Triggering by motion alarm ¥ Remote input pin Triggering by switchingInterface Settings Configuration Interface Settings ConfigurationTo program the unit through HyperTerminal Com ports TerminalHyperTerminal Baudrate 19200ActiveX Dialog Box Live Video and Server Push Video PagesAccessing These Pages Click Control to access the Device ControlsWEB Browser Control Pages Controlling the Display Matrix Control Live VIDEO/SERVER Push page Contents Genex Live VIDEO/SERVER Push page Contents C2900M-B 1/03 Spectra Live VIDEO/SERVER Push page Contents Esprit Live VIDEO/SERVER Push page Contents Advanced Features Automatic Connection FeatureVideo Motion Detection Feature Record and Play Back the Display on a PC Alarm Notification by E-MAILPlaying Back The Recording Recording The DisplayClick a or button. Click the button to resume playback Clicking the buttonFirmware Upload Troubleshooting Green Power LEDBasic Functioning Com LED Ethernet LEDsOutput LEDs Input LEDsTroubleshooting a TCP/IP Network Using a Ping Utility Video LEDsTerminal Program Troubleshooting the Video Connection Troubleshooting Connection ProblemsTesting the Audio Connection Test Between NET104A And NET101R-ATest Between NET104A And PC Specifications Dimensions Storage Temperature 4to 140F -20to 60C Storage HumidityLED Displays 41 to 104F 5 to 40CGlossary MAC Address Media Access Control/hardware address Internet Service ProviderSee Internet Protocol IP AddressUnshielded Twisted Pair See Wide Area NetworkWide Area Network Appendix a Connecting Pelconet NET104A to Various Components Refer to and the instructions that follow Connection ScenarioC2900M-B 1/03 KBD4000 Connected to a Multiplexer Refer to and the instructions that followC2900M-B 1/03 CM9760KBD Connected to a CM9760-CC1 Controller C2900M-B 1/03 Create a cable using the above diagram Connecting PelcoNet to Genex Using the COM in RS-232 PortUsing PelcoNet with CM9505 to Provide Remote Control Connecting a Pelconet Receiver to a System CM9502Using PelcoNet with CM9502 to Provide Connecting Pelconet to a CM9502 Ascii Serial PortC2900M-B 1/03 CM6700-MXB Connecting Pelconet to a CM6700 Ascii PortPelconet CM9760-DT Setup Using PelcoNet to Transmit Data and Video Between 9760 Nodes Using PelcoNet to Receive Data and Video Between 9760 Nodes Pelco recommends using Port ¥ Port 2 defaults to Ascii and RS-232Pelconet CM6800 Ascii Setup Using PelcoNet with CM6800 to Provide Remote ControlMenu Screen Manager Screen102 C2900M-B 1/03 Setup To Provide Remote ControlPart Can I view PelcoNet over the Internet? What TCP/IP ports does PelcoNet use?Can I enlarge the picture size in the browser? What software does PelcoNet require?106 C2900M-B 1/03 How do I program PelcoNet with HyperTerminal? How much bandwidth does PelcoNet use?Can I use PelcoNet with a DSL or cable connection? Index Idle state 59 Input level IP address set command 35 IP address settingVideo quality 49 Video resolution Version numbers for hardware/software 42 Video alarmVideo bandwidth ActiveX 50 Video priority Select area 55 Send emailWarranty and Return Information ISO9001