Pelco C2900M-B(1/03 manual Following explains a box-to-box connection

Page 23

The following explains a box-to-box connection.

1.First, transmitter (NET104A) and receiver (NET101R/R-A) need to be configured appropriately. If the units are supposed to be operated in different subnets, a gateway IP address must be configured. Use the alarm IP address field to address the destination. Also, the transmitterÕs video standard must be set to H.261. Enter the settings using either a terminal program or a web browser.

You also must disable Internet proxy settings. To do so: In Internet Explorer, click the Tools button, Internet Options, the Connections tab, and the LAN Settings button. Then remove the check mark in the Use a proxy server box. Click OK, and then OK again.

2.Once all addresses are configured, type c in the terminal window to establish the actual connection or program the live video receive IP and enable the live auto connect setting through the web browser. Make sure the alarm IP address in the unit that will initiate the connection points to the destination unit. After a few seconds, video transmission begins and the camera scene appears on the monitor attached to the receiver.

Instead of using a terminal program for establishing a connection, you can attach a contact to the alarm input. Make sure the alarm input is enabled.

You can use a web browser to connect to either of the two units, even during an active box-to-box connection. This way you can make changes to the configuration and immediately see the result of the setting (for example, when changing video quality). If you are connected to the transmitter, the camera pictures are sent to the receiver and web browser simultaneously. There will be a short break in the video display on the receiver monitor whenever the web browser requests a new frame. This is especially noticeable with the Server Push feature.

Full-duplex audio can be transmitted in parallel with the video transmission in units equipped to handle audio. To do so, you need to use the web browser to enable audio on the Audio Settings configuration page.

Transparent data is always transmitted automatically between the two units as soon as the connection becomes active. Data bytes entering the interface are transported to the other end transparently. There is no flow control mechanism for the data channel. Overflowing the serial interface will cause data loss.

To sever the connection from either end, type d in the respective terminal window (or disable the alarm).

C2900M-B (1/03)

23

Image 23
Contents Transmission Via Networks International Tel 1-559/292-1981 Fax 1-559/348-1120 D E N D U MContents Typical Session Command Reference Connection Scenario List of Illustrations List of Tables Unpacking Instructions Important Safeguards and WarningsTransmitter Instructions for the Network AdministratorMinimum Requirements BrowserRemember that the IP address must be unique on the network What is the Pelconet NET104A Transmission SYSTEM?HOW do LANs and WANs WORK? Description OverviewModels Package ContentsSoftware Version Front Panel LEDs Front Panel LEDsRear Panel Connectors Rear Panel ConnectorsConnecting a Camera or Monitor Quick Installation GuideConnect any additional items, such as alarms, audio, etc Connecting Additional ItemsConnecting to the LAN Port Key = Transmitter = AC power plug adapter Connecting PowerSelecting AN IP Address for Your Network What is NEXT?Displaying Remote Video on a WEB Browser Typical ApplicationsPelcoNet NET104A Home Displaying Video VIA a TRANSMITTER-TO-RECEIVER Connection Following explains a box-to-box connection LAN Box-To-Box Connection Transmitter, Receiver, Spectra Diagrams of Typical ApplicationsLAN Browser-To-Box Connection Transmitter, Browser, Spectra Video Browser Data Genex Spectra WAN Box-To-Box Connection Transmitter, Receiver, Spectra WAN Browser-To-Box Connection Transmitter, Browser, Spectra Video Data Genex Browser Spectra Up to four video sources can be connected to the NET104A Hardware InstallationConnecting Video Sources or Displays Connecting Audio EquipmentUse As Control Terminal Port Connecting Data TerminalsUse As Transparent Data Port Data Port Pin Assignments In RS-232 ModeNET 104A Connecting External SensorsPush the terminal block back on to the plug-in base Highlight Accessories. Click HyperTerminal ConfigurationConnecting to a LAN Configuration Using a Terminal ProgramTypical Session Connect to alarm IPSet the gateway IP address a set the alarm IP PelcoNet disconnects Command ReferencePelcoNet tries to call the alarm IP host Cmd DescriptionDisplay version information Closes the connection from the connecting IP addressToggles the Dhcp Dynamic Host Configuration Protocol on/off Display the unitÕs MAC addressNET-Manager Configuration Using a WEB BrowserWeb Server Concept PelcoNet NET104A Menu Tree Quick Guide To The Menu StructurePelcoNet NET104A Home C2900M-B 1/03 General Settings Configuration General ConfigurationDefault Description Setting Equipment on your network UpdateUpload the firmware and install it on the system 0.0Screen For Entering The Password Network Settings Configuration Base Port 25000 Five simultaneous live video connections Enable OffVideo port Video when using the multicasting protocol OffVideo Settings Configuration Video Settings ConfigurationConfiguration Default Setting Description 1000 Adjusted valueVideo Priority ActiveX Example, the InternetTime stamping Off IP address Images will be stored Login namePassword Partially obscure Time StampingAudio Settings Configuration Audio Settings ConfigurationDefault Setting Description Alarm Settings Configuration Alarm Settings ConfigurationSelect on to trigger an alarm in the event Video alarm OffTriggers the alarm Motion alarm OffAlarms Required to trigger an alarmMotion detection triggers an alarm Alarm indicator box lets you set aEnable all other alarms Alarm input OffAlarm input Master Alarm OffLive video 0.0 Live video in case of an alarmConnect Relay output can open the door remotely¥ Remote input pin Triggering by switching Bistable Select an operating mode for each relaySwitched on at the end of the alarm ¥ Motion alarm Triggering by motion alarmInterface Settings Configuration Interface Settings ConfigurationBaudrate 19200 Com ports TerminalTo program the unit through HyperTerminal HyperTerminalActiveX Dialog Box Live Video and Server Push Video PagesWEB Browser Control Pages Accessing These PagesClick Control to access the Device Controls Controlling the Display Matrix Control Live VIDEO/SERVER Push page Contents Genex Live VIDEO/SERVER Push page Contents C2900M-B 1/03 Spectra Live VIDEO/SERVER Push page Contents Esprit Live VIDEO/SERVER Push page Contents Video Motion Detection Feature Advanced FeaturesAutomatic Connection Feature Record and Play Back the Display on a PC Alarm Notification by E-MAILClicking the button Recording The DisplayPlaying Back The Recording Click a or button. Click the button to resume playbackFirmware Upload Basic Functioning TroubleshootingGreen Power LED Input LEDs Ethernet LEDsCom LED Output LEDsTerminal Program Troubleshooting a TCP/IP Network Using a Ping UtilityVideo LEDs Troubleshooting the Video Connection Troubleshooting Connection ProblemsTest Between NET104A And PC Testing the Audio ConnectionTest Between NET104A And NET101R-A Specifications 41 to 104F 5 to 40C Storage Temperature 4to 140F -20to 60C Storage HumidityDimensions LED DisplaysGlossary IP Address Internet Service ProviderMAC Address Media Access Control/hardware address See Internet ProtocolWide Area Network Unshielded Twisted PairSee Wide Area Network Appendix a Connecting Pelconet NET104A to Various Components Refer to and the instructions that follow Connection ScenarioC2900M-B 1/03 KBD4000 Connected to a Multiplexer Refer to and the instructions that followC2900M-B 1/03 CM9760KBD Connected to a CM9760-CC1 Controller C2900M-B 1/03 Create a cable using the above diagram Connecting PelcoNet to Genex Using the COM in RS-232 PortUsing PelcoNet with CM9505 to Provide Remote Control Connecting a Pelconet Receiver to a System CM9502Using PelcoNet with CM9502 to Provide Connecting Pelconet to a CM9502 Ascii Serial PortC2900M-B 1/03 CM6700-MXB Connecting Pelconet to a CM6700 Ascii PortPelconet CM9760-DT Setup Using PelcoNet to Transmit Data and Video Between 9760 Nodes Using PelcoNet to Receive Data and Video Between 9760 Nodes Pelco recommends using Port ¥ Port 2 defaults to Ascii and RS-232Pelconet CM6800 Ascii Setup Using PelcoNet with CM6800 to Provide Remote ControlMenu Screen Manager Screen102 C2900M-B 1/03 Setup To Provide Remote ControlPart What software does PelcoNet require? What TCP/IP ports does PelcoNet use?Can I view PelcoNet over the Internet? Can I enlarge the picture size in the browser?106 C2900M-B 1/03 Can I use PelcoNet with a DSL or cable connection? How do I program PelcoNet with HyperTerminal?How much bandwidth does PelcoNet use? Index Idle state 59 Input level IP address set command 35 IP address settingSelect area 55 Send email Version numbers for hardware/software 42 Video alarmVideo quality 49 Video resolution Video bandwidth ActiveX 50 Video priorityWarranty and Return Information ISO9001