18
TROUBLE SHOOTING
This is a self-diagnostic control system. The system will
automatically display flashing indicators if a problem is
detected.
No display at topside
No display at topside
- check that the topside is correctly plugged into spa
pack
- the power is on
- if problem persists contact Smart Protect Warranty
Display is flashing
Display is flashing
Apower failure must have occurred and the spa pack
has returned to its default values. Press any key to stop
the flashing and then reprogram the filter cycle.
Pump has started up for 1 minute on several occasions
Pump has started up for 1 minute on several occasions
and “Filter” indicator is flashing
and “Filter” indicator is flashing
This is a feature of the SMART WINTER MODE.
It protects your spa from the cold by turning the pump
on for 1 minute several times a day to prevent water
from freezing in the pipes.
W
Water temperatur
ater temperature is flashing
e is flashing
This indicates that the spa water temperature is over
112°F(44°C).
DO NOT enter the water! Remove spa cover and allow
the water to cool down. The system will reset itself
when the water temperature reaches 109°F(43°C)
Call Smart Protect Warranty if the problem persists.
Gr
Ground Fault Interr
ound Fault Interrupter T
upter Trips
rips
- Be sure that the neutral on the GFCI has been wired
properly in the main panel.
- Check if it does it only when heat turns on, if so check
element by removing the power to the element termi-
nal and turn the heat on. If it only faults when the ele-
ment is connected with power, the element has a
ground fault and must be replaced.
- This can be done by unplugging the pump, ozonator,
or any other peripheral equipment as a process of elim-
ination to see where the fault may be.