3 flashing dots are displayed
A PROBLEM HAS BEEN DETECTED.
Do NOT enter the water!
Check and open knife valves. Clean filter if necessary.
Check water level. Add water if needed.
Shut power off and power up your spa again to reset the system to default values. Reprogram your settings.
If 3 dots are still flashing, check high limit indicator light, located on the circuit board inside the spa pack. (It is a very bright L.E.D. red light that is easy to see when the pack cover is removed).
If this light is on, your spa has overheated, please call Smart Protect Warranty.
If this light is not on, refer to adjusting the pressure switch below.
PRESSURE SWITCH
IMPORTANT
Pressure switch adjustments may be a normal part of main- tenance of your spa.
Pressure switch adjustments are NOT covered by warranty.
How to adjust the pressure switch if 3 dots are flashing
-turn the pump off by pushing the pump button and/or turning the heat down below the current temperature.
-locate the pressure switch inside the spa pack.
-unlock the adjusting dial by sliding the locking bar up away from the dial. (located on right side of the pressure switch).
-turn the dial clockwise (increasing psi) until 3 dots are gone
19