20

OZONATORS

(OPTIONAL ON THE BASIC ARUBA SPAAND THE
DELUXE ARUBA SPA)
Ozone is injected into the spa’s water during the filtration
cycle. The ozone is injected into the water to supplement
chemical sanitizers, oxidize organics and control minerals. If
during a filter cycle the pump is manually turned on, the
ozonator will be suspended for 40 minutes after last pump or
blower times out or is turned off. After the suspension peri-
od or duration of the filtration cycle the ozonator will remain
off until the start of the next filter cycle.
Note: If you have the circulation system then the ozonator will run
continuously.
10 JET BLOWER SYSTEM
OPTIONAL PURCHASE ON THE DELUXE ARUBASPA
STANDARD OPTION ON THE EXECUTIVE AURBASPA
The blower system is operated by a 1.5 HP motor. When the
blower is activated at the topside control panel, water is aer-
ated through the blower jets creating small bubbles. Only air
passes through these jets. When you begin your start up,
ensure that the blower motor has not shifted and is plugged
into the spa pack tightly.The blower will turn on every filter
cycle, for 1 minute, to purge the lines.

WARNING

Do not block Ozone Jet at anytime.
Blocking the Ozone Jet may result in
damaging the Ozonator and voiding the
warranty.

IMPORTANT

It is necessary to use Chlorine or Bromine
chemical treatment with an ozonator.
WARNING
This system only accepts a 220v Ozonator.