Parker Hannifin 88-020292-01 A manual Mount the Drive, Environmental Considerations

Page 25

5 –MOUNT THE DRIVE

Dimensions of the E-AC Drive are shown below.

4.34

(110.1)

4.10

(104.1)

0.43

(10.8)

5.35

(135.9)

4.500

(114.3)

Dimensions in inches (mm)

2x clearance for

 

#8 or M4 mounting screws

Dimensions – E-AC Drive

1.89

(48.1)

0.18

(4.6)

1.59

(40.5)

 

I/O

SERIES

DRIVE

PWR/FLT

L1

120V

N

 

 

A +

MOTOR

A -

 

 

B +

 

 

B -

 

 

Compumotor

ENVIRONMENTAL CONSIDERATIONS

TEMPERATURE SPECIFICATIONS

 

 

Maximum Ambient Temperature:

50° C

(122° F)

Minimum Ambient Temperature:

0° C

(32° F)

Overtemperature Shutdown Fault:

55° C

(131° F)

The E-AC Drive has an internal temperature sensor, located near the heatsink. If the sensor reaches 55° C (131° F), it will trigger an overtem- perature fault, and the drive will shut down.

FAN COOLING

Operating the E-AC Drive in high ambient temperatures may require fan cooling to keep the drive from shutting down due to an overtemperature fault.

HUMIDITY

Keep the relative humidity below 95%, non-condensing.

LIQUIDS

Do not allow liquids or fluids to come into contact with the E-AC Drive or its cables.

AIRBORNE CONTAMINANTS

Particulate contaminants, especially electrically conductive material such

E-AC Drive Hardware Installation Guide

Chapter 2 – Installation

25

Image 25
Contents AC Drive Hardware Installation Guide User Information Table of Contents AC Drive Hardware Installation Guide Introduction AC Drive Hardware Installation Guide IntroductionBlock Diagram of E-AC Drive System DIP SwitchesAC Drive -DESCRIPTION System ComponentsCompumotor Family of Products AC Drive -COMPATIBLE MotorsInputs & Outputs ANTI-RESONANCEAC Drive Hardware Installation Guide Introduction Installation Installation Overview PrecautionsWhat YOU should have Ship KIT PartComponent Locations AC Drive Hardware Installation Guide Installation ProcedureAutomatic Test Automatic Test SetupConnect AC Power Select a Motor InstallationSPEED/TORQUE Curves Parameters Units Motor SpecificationsBearings Information Size 17 FrameDimensions in inches mm Motor DimensionsPage Motor Connector Wired for Series Motor Current Connect the Motor to the Drive -WIRINGPrecautions Connecting the Motor Series WiringConnecting the Motor Parallel Wiring Motor Connector Wired for Parallel Motor CurrentSeries Versus Parallel -SUMMARY DIP Switch Location and Settings SET DIP SwitchesDefault Settings Motor CurrentANTI-RESONANCE Disable Drive ResolutionWaveform Automatic TestDrive I/O Connector Connecting a Compumotor ControllerConnect a Controller -INPUTS & Outputs Step InputShutdown Input Direction InputReset Input Fault OutputMount the Drive Dimensions E-AC DriveEnvironmental Considerations Panel Layout Panel Layout DimensionsMount the Motor Motor Modifications Motor Temperature & CoolingExtending Motor Cables Less than 100 ft m 100 -200 ft -60 m Motor TypeMisalignment Condition Connect the Motor to the Load -COUPLERSApply Power Connect AC PowerAC Input Connections Peak Power Ratings Test the InstallationTest Procedure AC Drive Hardware Installation Guide Troubleshooting TroubleshootingDiagnostic Leds Troubleshooting BasicsOvertemperature Protection Protective CircuitsTechnical Support ANTI-RESONANCE DisableShort Circuit Protection Product Return Procedure Using Non-Compumotor Motors Wiring Configurations Using NON-COMPUMOTOR MotorsLead Motor Lead Motor Labeling the Leads Direction of Motor Rotation Terminal ConnectionsNon-Compumotor Motor Connections Lead Motors Setting Motor Current NON-COMPUMOTOR MotorsPage Regulatory Compliance UL and CE Electromagnetic Compatibility EMC Installation Requirements Low Voltage Directive LVD Installation RequirementsAgency Additional Steps User Must Take Filter EMC CablingClamp Type Cable ShieldingPanel Mounting the E-AC Drive Page Index AC Drive Hardware Installation Guide IndexAC Drive Hardware Installation Guide Index