Parker Hannifin 88-020292-01 A manual Terminal Connections, Direction of Motor Rotation

Page 38

TERMINAL CONNECTIONS

After you determine the motor’s wiring configuration, connect the motor leads to the E-AC Drive’s MOTOR terminals according to the following figure.

4-Lead Motor

E-AC Drive

A+

A +

A–

A -

 

B +

B+

B -

 

 

B–

6-Lead Motor

E-AC Drive

A+

A Center

A-CT

 

Tap

 

A +

A–

A-

B+

B -

B+

 

B Center

B-CT

Tap

 

B–

8-Lead Motor

 

Series

E-AC Drive

A1

A Center

A2

A3

Tap

A +

A4

A-

B+

B1

B -

B2

B CenterB3

Tap

B4

 

8-Lead Motor

 

Parallel

E-AC Drive

A1

 

A2

 

A3

A +

A4

A-

B+

B1

B -

B2

B3

B4

Non-Compumotor Motor Connections

WARNING

The E-AC Drive has no Center Tap terminals. You must insulate and

properly secure the ends of the motor’s center tap wires.

DIRECTION OF MOTOR ROTATION

The procedures above do not determine the direction of motor shaft rotation. To find out which direction the shaft turns, you must power up your system and command motion. If the shaft turns in the opposite direction than you desire, exchange the motor leads connected to A+ and A– to reverse the direction of rotation.

WARNING

Motor shaft rotation may be opposite than you expect. Do not connect a load to the shaft

until you first determine the direction of shaft rotation.

38

E-AC Drive Hardware Installation Guide

Appendix A – Non-Compumotor Motors

Image 38
Contents AC Drive Hardware Installation Guide User Information Table of Contents AC Drive Hardware Installation Guide AC Drive Hardware Installation Guide Introduction IntroductionAC Drive -DESCRIPTION DIP SwitchesBlock Diagram of E-AC Drive System System ComponentsInputs & Outputs AC Drive -COMPATIBLE MotorsCompumotor Family of Products ANTI-RESONANCEAC Drive Hardware Installation Guide Introduction Installation What YOU should have Ship KIT PrecautionsInstallation Overview PartInstallation Procedure Component Locations AC Drive Hardware Installation GuideAutomatic Test Setup Automatic TestConnect AC Power SPEED/TORQUE Curves InstallationSelect a Motor Bearings Information Motor SpecificationsParameters Units Size 17 FrameMotor Dimensions Dimensions in inches mmPage Precautions Connect the Motor to the Drive -WIRINGMotor Connector Wired for Series Motor Current Connecting the Motor Series WiringSeries Versus Parallel -SUMMARY Motor Connector Wired for Parallel Motor CurrentConnecting the Motor Parallel Wiring Default Settings SET DIP SwitchesDIP Switch Location and Settings Motor CurrentWaveform Drive ResolutionANTI-RESONANCE Disable Automatic TestConnect a Controller -INPUTS & Outputs Connecting a Compumotor ControllerDrive I/O Connector Step InputDirection Input Shutdown InputFault Output Reset InputEnvironmental Considerations Dimensions E-AC DriveMount the Drive Mount the Motor Panel Layout DimensionsPanel Layout Extending Motor Cables Motor Temperature & CoolingMotor Modifications Less than 100 ft m 100 -200 ft -60 m Motor TypeConnect the Motor to the Load -COUPLERS Misalignment ConditionAC Input Connections Connect AC PowerApply Power Test Procedure Test the InstallationPeak Power Ratings Troubleshooting AC Drive Hardware Installation Guide TroubleshootingOvertemperature Protection Troubleshooting BasicsDiagnostic Leds Protective CircuitsShort Circuit Protection ANTI-RESONANCE DisableTechnical Support Product Return Procedure Using Non-Compumotor Motors Lead Motor Using NON-COMPUMOTOR MotorsWiring Configurations Lead Motor Labeling the Leads Non-Compumotor Motor Connections Terminal ConnectionsDirection of Motor Rotation Setting Motor Current NON-COMPUMOTOR Motors Lead MotorsPage Regulatory Compliance UL and CE Agency Additional Steps User Must Take Low Voltage Directive LVD Installation RequirementsElectromagnetic Compatibility EMC Installation Requirements EMC Cabling FilterCable Shielding Clamp TypePanel Mounting the E-AC Drive Page AC Drive Hardware Installation Guide Index IndexAC Drive Hardware Installation Guide Index