ADJUSTMENT OF THE TPAE TRANSPORTING SECTION. (CONTINUED)
A. Adjustment of the S/T GUIDE ROLLER
a.Check the Playing back with a
b.Make sure that excessive tape wrinkle does not occure at eatch S.T GUIDE ROLLER.
c.If tape wrinkle is observed at the S/T GUIDE ROLLER, turn the guide roller screw until there is not tape wrinkle.
B. Adjustment of the AC HEAD ASS’Y(TILT)
a.Play back a
b.If there is any problem, Turn the AC HEAD TILT SCREW until the running status improved (Fig. 5.2)
FIg.5.2 Adjustment of the AC HEAD ASS’Y
C. Adjustment of the AC HEAD Height(Fig. 5.3)
a.Play back
b.Make sure that the gap between the lower end of AC head is 0.25m.
c.If the measurement of the gap is different from the refer- ence value 0.25m, turn the screw !,#until the desired gap is obtained.
FIg.5.3 Adjustment of |
D. Adjustment of the AUDIO AZIMUTH(Fig. 5.4)
a.Play back the ALIGNMENT TAPE (DN2 : SP, NTSC,7KHz)
b.Check the AUDIO output with a AUDIO LEVEL METER.
c.Turn the AC HEAD AZIMUTH SCREW @until the maximum AUDIO
FIg.5.4 Adjustment of AUDIO AZIMUTH, |
E. Adjustment of the X-POSITION(Fig. 5.4 5.5)
a.Connect the PATH ADJ. FIXTURE to the PT01 on the
MAIN CIRCUIT BOARD.
b.Play back theALIGNMENT TAPE (DN2 : SP MONOSCOPE).
c.Connect the S/W pin and ENVE pin of the PATH ADJ. FIXTURE with the SCOPE PROBE.
d.Insert the adjustment bar in the AC HEAD ADJUST hole $and adjust the
*Three is the possibility that an another TRACKING CEN- TER can be occur when the AC HEAD ASS’Y turned completely in the counterclockwise direction, Hence adjust the
e.The adjustment of the
Test Point | S/W PULSE TEST PIN | PATH ADJ. FIXTURE | |
ENVELOPE TEST PIN | PATH ADJ.FIXTURE | ||
| |||
Measurement Equipment | OSILLOSCOPE |
| |
Adjustment | VR CONTROL | PATH ADJ.FIXTURE | |
|
| ||
AC HEAD ADJUST HOLE | ADJUSTMENT BAR | ||
| |||
|
|
|
21