Getting Started (continued)
Names and Functions (Signal In/Out Terminal)
(Rear) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
AUDIO IN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 | 2 | 3 | 4 | 5 | 6 |
| 7 | 8 | 9 | 10 | 11 |
|
|
| 12 |
|
| 13 |
|
|
| 14 | 15 | 16 |
|
| ||
VIDEO IN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
THRU OUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SCSI |
|
|
|
|
|
|
| CAUTION |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| AUDIO OUT |
| VIDEO OUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| RISK OF ELECTRIC SHOCK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| LAN |
|
|
|
|
| DO NOT OPEN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| UPS | 1 | 2 | 1 | 2 |
| AVIS:RISQUE DE CHOC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ELECTRIQ |
|
|
|
|
|
|
|
|
|
|
|
| 1 | 4/ | 16 | 5 | 8 | AC IN |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ) | |
|
|
|
|
|
|
|
|
|
| 1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | RST | COM | IN | IN | EXT REC |
|
|
|
| SIGNAL GND |
|
|
|
|
|
|
|
|
|
|
| 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | OUT |
| CLK | SER |
| 9 | 12 | 13 | 16 |
|
|
|
|
|
|
|
|
|
|
|
| WAR | RST | REC | COM |
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ALARM |
|
|
| OUT | OUT | OUT |
|
| EE OUT |
|
|
|
1ALARM IN
CAMERA 1, 3, 5, 7, 9, 11, 13, 15
CAMERA 2, 4, 6, 8, 10, 12, 14, 16
2ALARM RESET
3CLOCK RESET IN
4SERIES REC IN
5EXT REC IN 6COM
1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | RST COM | IN IN EXT REC |
2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 |
| CLK SER |
OUT WAR RST REC COM | |||||||||
|
|
|
| ALARM |
|
| OUT | OUT OUT | |
|
|
|
|
|
|
|
|
| 7SERIES REC OUT |
|
|
|
|
|
|
|
|
| 8CLOCK RESET OUT |
|
|
|
|
|
|
|
| 9WARNING OUT | |
|
|
|
|
|
|
|
| 0ALARM REC OUT |
1[ALARM IN] Terminal (Supports Channels 1 - 16) Terminal that accepts input signals to start alarm or sensor recording.
2[ALARM RESET] Input Terminal
Terminal that accepts signals to stop recording during alarm or sensor recording.
5[EXT REC IN] Terminal
Starts recording automatically upon receiving external sig- nals when the “EXT REC MODE” is set as “TRIGGER” or “MANUAL”.
☞Page 25 ‘OPERATION/EXT REC Menu’
☞Page 61 ‘Activation of Recording Via External Signals’
3[CLOCK RESET IN] Terminal
For connection to a master clock or the [CLOCK RESET OUT] terminal of other devices. This equipment can be set to a master clock or the clock of other devices upon the input of clock reset signals.
The clock in
•When the value is 29 seconds or less, this will be reset to 00 seconds with the minute value unchanged.
•When the value is 30 seconds and above, this will be reset to 00 seconds with the minute rounded to the next higher value.
☞Page 61 ‘Series Recording Using 2 or More
4[SERIES REC IN] Terminal
Series recording will start upon the input of [SERIES REC OUT] signals. This is the terminal that accepts the series recording signals of other
☞Page 61 ‘Series Recording Using 2 or More
6[COM] Common Ground Terminal
This is a common ground terminal. For connection to the signal ground terminal of other devices.
7[SERIES REC OUT] Terminal
Outputs signals when the remaining hard disk space is 1 % or less.
However, there will be no signal output in the following cir- cumstances:
• When the “SERIES REC” item is set as “OFF” in the menu. ☞ Page 25 ‘OPERATION/EXT REC Menu’
☞ Page 61 ‘Series Recording Using 2 or More
8[CLOCK RESET OUT] Terminal
Terminal for output of clock reset signals. Signals are out- put in the following cases:
When the internal clock of
☞Page 61 ‘Series Recording Using 2 or More
9[WARNING OUT] Terminal
Outputs signals during hard disk malfunction or error oc- currence. (☞ Page 105)
0[ALARM REC OUT] Terminal
Outputs signals when
10