External Control Device Setup

Set ID

-Use this function to specify a monitor ID number.

-Refer to ‘Real Data Mapping 1’. See page 34.

1. Press the MENU button and then use the D / E button to select the SPECIAL

menu.

PICTURE

2. Press the G button and then use D / E button to select Set ID.

SOUND

TIMER

1

Language

Key lock

ISM Method

Low power

3. Press the G button and then use F / G button to adjust Set ID to choose the

SPECIAL

Set ID

G

 

 

Demo

 

 

 

 

 

 

 

Index

 

desired monitor ID number.

SCREEN

• The adjustment range of Set ID is 1 ~ 99.

PIP/DW Menu Prev.

Communication Parameters

• Baud rate : 9600 bps (UART)

• Stop bit : 1 bit

• Data length : 8 bits

• Communication code : ASCII code

• Parity : None

 

Command Reference List

 

COMMAND 1 COMMAND 2

DATA

 

 

 

 

(Hexadecimal)

01. Power

k

a

0

~ 1

02.

Input Select

k

b

1

~ 9

03. Aspect Ratio

k

c

0

~ 3

04. Screen Mute

k

d

0

~ 1

05. Volume Mute

k

e

0

~ 1

06.

Volume Control

k

f

0

~ 64

07.

Contrast

k

g

0

~ 64

08.

Brightness

k

h

0

~ 64

09.

Color

k

i

0

~ 64

10. Tint

k

j

0

~ 64

11. Sharpness

k

k

0

~ 64

12. OSD Select

k

l

0

~ 1

13.

Remote Control Lock Mode

k

m

0

~ 1

14. PIP/DW

k

n

0

~ 3

15.

Split Zoom

k

p

0

~99

16.

PIP Position

k

q

0

~ 3

17. Treble

k

r

0

~ 64

18. Bass

k

s

0

~ 64

19.

Balance

k

t

0

~ 64

20.

Color Temperature

k

u

0

~ 2

21.

PIP Input Select

k

y

1

~ 9

22. Abnormal State

k

z

0

~ a

23. ISM Method

j

p

0

~ 3

24. Low Power

j

q

0

~ 1

25.

Picture Size Setting

j

t

0

~30

 

for DW mode

 

 

 

 

26. Auto Configure

j

u

1

 

27. Key

m

c

Key code

Transmission / Receiving Protocol

Transmission

[Command1][Command2][ ][Set ID][ ][Data][Cr]

*[Command 1]: k, j, m

*[Command 2]: To control PDP set.

*[Set ID]: You can adjust the set ID to choose desired moni- tor ID number in Special menu. Adjustment range is 1 ~ 99. When selecting Set ID ‘0’, every con- nected PDP set is controlled. Set ID is indicated as decimal (1~99) on menu and as Hexa decimal (0x0~0x63) on transmission/receiving protocol.

*[DATA]: To transmit command data.

Transmit ‘FF’ data to read status of command.

*[Cr]: Carriage Return ASCII code ‘0x0D’

* [ ]: ASCII code ‘space (0x20)’

OK Acknowledgement

[Command2][ ][Set ID][ ][OK][Data][x]

*The Monitor transmits ACK (acknowledgement) based on this format when receiving normal data. At this time, if the data is data read mode, it indicates present status data. If the data is data write mode, it returns the data of the PC computer.

Error Acknowledgement

[Command2][ ][Set ID][ ][NG][x]

*The Monitor transmits ACK (acknowledgement) based on this format when receiving abnormal data from non-viable functions or communication errors.

Data 1: Illegal Code

2: Not supported function

32 Plasma Monitor

Image 32
Contents MW-71PY10 MW-71PY10G FCC Notice Class B digital deviceSafety Instructions This may cause a fire or an electric shock Safety InstructionsSafety instruction MW-71PY10G only Contents What is a Plasma Display Panel PDP? Wide angle range of visionWide Screen MultimediaControls Front Panel ControlsConnection Options Thumbstick Up/Down/Left/Right/ENTER Remote Control Key FunctionsNumber buttons Installation Option ExtrasInstallation Instructions Wall Mount Installation Desktop Pedestal InstallationVCR Setup How to connectHow to use External Equipment ConnectionsCable TV Setup Cable BoxDigital Set-top Box DTV SetupComponent Input ports PC Setup Monitor Display Specifications RGB-PC / DVI-PC Mode Resolution Horizontal VerticalHdmi ReferenceMenu Language Selection Turning on the Monitor just after installationTurning on the Monitor APC Auto Picture Control Auto Color Temperature ControlPicture Menu Options SRGB only RGB-PC, DVI-PC Modes Manual Picture Control Off optionAVL Auto Volume Leveler Sound Menu OptionsDasp Digital Auto Sound Processing Manual Sound Control Dasp Off option and balanceTimer Menu Options Clock SetupOn/Off Timer Setup Sleep TimerLow Power Special Menu OptionsKey Lock ISM Image Sticking Minimization MethodSpecial Menu Options XD DemoScreen Menu Options Auto AdjustmentSetting Picture Format Screen Position Manual Configure RGB-PC mode onlySplit Zoom Initializing Reset to original factory value Selecting Wide VGA mode RGB-PC mode onlyScreen Adjustments Video1-2 and Component 480i mode only Cinema Mode Setup Video1-2 and Component 480i mode onlyPIP Picture-In-Picture Feature DW Setup Option Sub Picture Size AdjustmentWatching DW Selecting a Source for the DWRS-232C Configurations External Control Device SetupType of Connector D-Sub 9-pin Male Command Reference List External Control Device SetupPower Command 2a Screen Mute Command 2dInput Select Command 2b Main Picture Input Aspect Ratio Command 2c Main picture formatContrast Command 2g Brightness Command2hTint Command2j Sharpness Command2kPIP / DW Command2n Split Zoom Command2pPIP Position Command2q Treble Command2rPIP Input Select Command2y Abnormal State Command2zLow Power Command2q Picture Size Setting for DW mode Command2tIR Code How to ConnectRemote Control IR Code Code Hexa Function Programming a code into a remote mode Programming the RemoteProgramming Codes VCRsHdstb AudioTroubleshooting Checklist Product Specifications Operating Temperature RangePlasma Monitor Page Warranty Period HOW Service is Handled To Contact the LGE Customer Service Center by Mail No 3828VA0484A a RF04FA