LG Electronics MW 71PY10 PIP Input Select Command2y, Abnormal State Command2z, Key Command2c

Page 36

External Control Device Setup

21. PIP Input Select (Command2:y)

GTo select input source for sub picture in PIP mode.

Transmission

[k][y][ ][Set ID][ ][Data][Cr]

Data

1

: Video1

6

: DVI

 

2

: Video2

7

: Video3

 

3

: Component1

8

: Video4

 

4

: Component2

9

: HDMI

 

5

: RGB

 

 

Acknowledgement

 

 

 

 

 

[y][ ][Set ID][ ][OK][Data][x]

 

 

 

 

 

 

 

Data

1

: Video1

6

: DVI

 

2

: Video2

7

: Video3

 

3

: Component1

8

: Video4

 

4

: Component2

9

: HDMI

5: RGB

22.Abnormal State (Command2:z)

G To recognize an abnormal state.

Transmission

[k][z][

][Set ID][ ][FF][Cr]

 

 

 

 

Data

FF:Read

 

Acknowledgement

 

 

 

[z][ ][Set ID][ ][OK][Data][x]

 

 

 

 

Data

0: Power on(signal)

6: AC detect off

 

1: Power on(No signal)

7: Fan Alarm off

 

2: Remote control off

8: Off timer off

 

3: Sleep time off

9: No signal off

 

4: RS-232C off

a: Connection Detect off

5:5V monitor off

*If you do not press any button within 2 hours after the monitor turns on with the On Timer function, the monitor will automatically revert to standby mode.

24. Low Power (Command2:q)

G To control the low power function on/off.

Transmission

[j][q][ ][Set ID][ ][Data][Cr]

Data 0: Low power off 1: Low power on

Acknowledgement

[q][ ][Set ID][ ][OK][Data][x]

Data 0: Low power off

1:Low power on

25.Picture Size Setting for DW mode (Command2:t)

G To adjust main picture size in DW mode.

Transmission

[j][t][ ][Set ID][ ][Data][Cr]

Data Min: 0 ~ Max: 30

Refer to ‘Real data mapping1’. See page 34. Acknowledgement

[t][ ][Set ID][ ][OK][Data][x]

Data Min: 0 ~ Max: 30

26. Auto Configure (Command2:u)

G To adjust picture position and minimize image shaking automatically. Auto Configure only works in RGB-PC mode.

Transmission

[j][u][ ][Set ID][ ][Data][Cr]

Data 1

Refer to ‘Real data mapping1’. See page 34. Acknowledgement

[u][ ][Set ID][ ][OK][Data][x]

Data 1

23. ISM Method (Command2:p)

G To avoid having a fixed image remain on screen.

Transmission

[j][p][

][Set ID][ ][Data][Cr]

 

 

 

 

 

 

Data

0: Normal

2: Orbiter

 

1: White wash

3: Inversion

Acknowledgement

 

 

 

 

 

[p][ ][Set ID][ ][OK][Data][x]

 

 

 

 

 

 

Data

0: Normal

2: Orbiter

 

1: White wash

3: Inversion

27. Key (Command2:c)

G To adjust Key code for IR remote control.

Transmission

[m][c][ ][Set ID][ ][Data][Cr]

Data Key code : Refer to See page 38.

Acknowledgement

[c][ ][Set ID][ ][OK][Data][x]

36 Plasma Monitor

Image 36
Contents MW-71PY10 MW-71PY10G FCC Notice Class B digital deviceSafety Instructions Safety Instructions Safety instruction MW-71PY10G onlyThis may cause a fire or an electric shock Contents What is a Plasma Display Panel PDP? Wide angle range of visionWide Screen MultimediaControls Front Panel ControlsConnection Options Remote Control Key Functions Number buttonsThumbstick Up/Down/Left/Right/ENTER Installation Option ExtrasInstallation Instructions Wall Mount Installation Desktop Pedestal InstallationVCR Setup How to connectHow to use External Equipment ConnectionsCable TV Setup Cable BoxDTV Setup Component Input portsDigital Set-top Box PC Setup Monitor Display Specifications RGB-PC / DVI-PC Mode Resolution Horizontal VerticalHdmi ReferenceTurning on the Monitor just after installation Turning on the MonitorMenu Language Selection Auto Color Temperature Control Picture Menu OptionsAPC Auto Picture Control SRGB only RGB-PC, DVI-PC Modes Manual Picture Control Off optionAVL Auto Volume Leveler Sound Menu OptionsDasp Digital Auto Sound Processing Manual Sound Control Dasp Off option and balanceTimer Menu Options Clock SetupOn/Off Timer Setup Sleep TimerLow Power Special Menu OptionsKey Lock ISM Image Sticking Minimization MethodSpecial Menu Options XD DemoAuto Adjustment Setting Picture FormatScreen Menu Options Manual Configure RGB-PC mode only Split ZoomScreen Position Initializing Reset to original factory value Selecting Wide VGA mode RGB-PC mode onlyScreen Adjustments Video1-2 and Component 480i mode only Cinema Mode Setup Video1-2 and Component 480i mode onlyPIP Picture-In-Picture Feature DW Setup Option Sub Picture Size AdjustmentWatching DW Selecting a Source for the DWExternal Control Device Setup Type of Connector D-Sub 9-pin MaleRS-232C Configurations Command Reference List External Control Device SetupPower Command 2a Screen Mute Command 2dInput Select Command 2b Main Picture Input Aspect Ratio Command 2c Main picture formatContrast Command 2g Brightness Command2hTint Command2j Sharpness Command2kPIP / DW Command2n Split Zoom Command2pPIP Position Command2q Treble Command2rPIP Input Select Command2y Abnormal State Command2zLow Power Command2q Picture Size Setting for DW mode Command2tHow to Connect Remote Control IR CodeIR Code Code Hexa Function Programming a code into a remote mode Programming the RemoteProgramming Codes VCRsHdstb AudioTroubleshooting Checklist Product Specifications Operating Temperature RangePlasma Monitor Page Warranty Period HOW Service is Handled To Contact the LGE Customer Service Center by Mail No 3828VA0484A a RF04FA