Command Reference List
* When setting the 24 ~ 34, a menu doesn’t display on screen.
|
| COMMAND1 | COMMAND2 | DATA |
| COMMAND1 | COMMAND2 | DATA | |
|
| (Hexadecimal) |
| (Hexadecimal) | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 ~ 1 |
|
|
|
| 0 ~ 64 |
01. | Power | k | a | 18. | Balance | k | t | ||
02. Input Select | k | b | 0 ~ 8 | 19. | Colour Temperature(CSM) | k | u | 0 ~ 3 | |
03. Aspect Ratio | k | c | Refer to p.84 | 20. Red Adjustment | k | v | 0 ~ 50 | ||
04. Screen Mute | k | d | 0 ~ 1 | 21. | Green Adjustment | k | w | 0 ~ 50 | |
05. Volume Mute | k | e | 0 ~ 1 | 22. Blue Adjustment | k | $ | 0 ~ 50 | ||
06. Volume Control | k | f | 0 ~ 64 | 23. | PIP input Source | k | y | 0 ~ 8 | |
07. | Contrast | k | g | 0 ~ 64 | 24. | Abnormal Status | k | z | 0 ~ 9 |
08. Brightness | k | h | 0 ~ 64 | 25. ISM Method (option) | j | p | 0 ~ 3 | ||
09. Colour | k | i | 0 ~ 64 | 26. Low Power (option) | j | q | 0 ~ 1 | ||
10. | Tint (option) | k | j | 0 ~ 64 | 27. | Orbiter Time Setting (option) j | r | 1 ~ FE | |
11. | Sharpness | k | k | 0 ~ 64 | 28. | Orbiter Pixel Setting (option) | j | s | 1 ~ 3 |
12. | OSD Select | k | l | 0 ~ 1 | 29. Picture Size (option) | j | t | 0 ~ 20 | |
13. | Remote Control | k | m | 0 ~ 1 | 30. | Auto Configure (option) | j | u | 1 |
|
|
|
|
|
|
|
|
|
|
| Lock Mode |
|
|
| 31. | Programme selection | m | a | 0 ~ 63 |
14. | PIP/DW | k | n | Refer to p.85 | 32. | Send IR Code | m | c | Key Code |
15. | PIP Position | k | q | 0 ~ 3 | 33. | Input select (Main) | x | b | Refer to p.87 |
16. | Treble | k | r | 0 ~ 64 | 34. | Input select (PIP) | x | y | Refer to p.87 |
17. | Bass | k | s | 0 ~ 64 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Transmission / Receiving Protocol
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
[Command 1] | : First command to control set. (j, k, m or x) | |
[Command 2] | : Second command to control set. | |
[Set ID] | : You can adjust the set ID to choose | |
|
| desired set ID number in special menu. |
|
| Adjustment range is 1 ~ 99. |
|
| When selecting Set ID ‘0’, every |
|
| connected set is controlled. |
|
| Set ID is indicated as decimal (1~99) on |
|
| menu and as Hexa decimal (0x0~0x63) on |
|
| transmission/receiving protocol. |
* | [DATA] | : To transmit command data. |
|
| Transmit ‘FF’ data to read status of |
|
| command. |
* | [Cr] | : Carriage Return |
|
| ASCII code ‘0x0D’ |
* | [ ] | : ASCII code ‘space (0x20)’ |
OK Acknowledgement
[Command2][ ][Set ID][ ][OK][Data][x]
The set transmits ACK (acknowledgement) based on this format when receiving normal data. At this time, if the data is data read mode, it indicates present status data. If the data is data write mode, it returns the data of the PC computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
The set transmits ACK (acknowledgement) based on this format when receiving abnormal data from
Data1: Illegal Code
Data2: Not supported function
Data3: Wait more time
APPENDIX
83