Heath Zenith SL-9526 manual Test and Adjustment, Specifications, Avoid aiming the control at

Page 3

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has about 1 1/2 minutes warm up period before it will detect motion. When first turned on, wait about 1 1/2 minutes.

Turn the RANGE control to the mid position and the ON-TIME control to the TEST position.

ON-TIME

RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

MIN MAX

Loosen the clamp screw in the sensor ball joint and gently ro- tate the sensor.

Walkthroughthecoveragearea noting where you are when the lights turn on (also, the LED will flash several times when mo- tion is detected). Move the sen- sor head up, down, or sideways to change the coverage area.

Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the RANGE as needed. RANGE set too high may increase false triggering.

Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.

Clamp

Screw

Ball

Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

180°

8 ft.

(2.4 m)

70 ft.

(21 m)

Maximum Range

Maximum

 

Coverage Angle

The detector is most sensitive to motion across its field of view.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5 or 10 minutes).

Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range . . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].

Sensing Angle . . . . . . . . Up to 180°

Electrical Load . . . . . . . . Up to 300 Watt Maximum In- candescent [Up to 150 Watt maximum each lamp holder.]

Power Requirements . . . 120 VAC, 60 Hz

Operating Modes . . . . . . TEST, AUTO and MANUAL MODE

Time Delay . . . . . . . . . . 1 , 5, 10 minutes

DESA Specialty Products™ reserves the right to dis- continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

Motion

Motion

Sensor

Least Sensitive

Most Sensitive

598-1147-00

3

Image 3
Contents Requirements FeaturesMode Switching Summary OperationWhite to InstallationTurn power off at the fuse or circuit breaker Wall Mount Eave MountAim Sensor Down for Short Coverage Higher for Long Test and AdjustmentSpecifications Turn on the circuit breaker and light switchTroubleshooting Guide Technical ServiceDo Not Send Products Limited Warranty Exclusions and Limitations Requisitos FuncionamientoCaracter’sticas Resumen de las modalidades delApague la energ’a en el fusible o cortacircuitos InstalacionMontaje en pared Montaje en alero Blanco a blancoParte de abajo del detector Evite apuntar el control hacia Prueba Y AjusteEspecificaciones Prenda el cortacircuitos y el interruptor de luzNo enviar los productos Guia DE Investigacion DE AveriasExclusiones y limitaciones de la garant’a limitada Exigences RŽsumŽ du mode de commutationFonctionnement CaractŽristiquesCåBLAGE DE LA Commande DÕƒCLAIRAGE Montage mural Montage sous Avant-toitBlanc /blanc Vers des endroits où des animaux, des vŽhicules Fiche TechniqueƑviter de pointer lÕappareil Rapidement, tels que des bouches dair chaud etNenvoyez pas de produits Service TechniqueExclusions et restrictions de la Garantie limitŽe 598-1147-00