Black Box PCW22A-R4, PCW22A-R3 manual Switch #4 on =, Self-Diagnostics

Page 10

CHAPTER 3: Installation

Switch #4 ON =

Self-Diagnostics Mode.

OFF =

Normal Operation.

Switch #5, #6—Block Size Specification.

5

6

 

OFF

OFF

80 Characters

OFF

ON

128 Characters

ON

OFF

256 Characters

ON

ON

512 Characters

NOTE

For 3741, set SW3, Switch #5: OFF (Fixed length)SW2, Switch #5: OFF, and Switch #6: OFF (128 character block)

Switch #7, #8—Asynchronous Parity Specification.

7

8

 

OFF

OFF

Space Parity (always 0)

OFF

ON

Mark Parity (always l)

ON

OFF

Odd Parity

ON

ON

Even Parity

NOTE

The A/S-2G only recognizes a 7-bit, 1 bit parity sequence. 8-bit data, no parity is the same as 7-bit, space parity. If you have 8-bit data, no parity, set SW2, Switches #7 and #8 to the OFF position.

3.2.3 SELF-DIAGNOSTICS

There are two ways to enter the self-diagnostic mode. The first method requires that you locate SW2, switch #4 and set it to the ON position. When you press the reset switch, the A/S-2G will display diagnostic information (see below) on a terminal or printer connected to Port A.

The second method requires a terminal connected to Port A. When you type an ampersand (“&”) and then a pound sign (“#”), the A/S-2G will enter the Self-Diagnostics/Reconfigure Switch Menu. Press the “l” key to enter the self-diagnostics mode and the A/S-2G will display diagnostic information on your terminal.

This is what the A/S-2G does in self-diagnostic mode:

Displays its software version

Checks the ROM

Checks the RAM

Displays the state of SW3

Displays the state of SW2

Displays the state of SW1 Port A

Displays the state of SW1 Port B

The information for SW3, SW2, and SW1 is listed in binary: 1=ON and 0=OFF.

9

Image 10
Contents Protocol Converter FCC Statement Protocol Converter A/S-2G Table of Contents Synchronous Device to Asynchronous Device Specifications RXCIntroduction Unpacking and Inspection InstallationData Flow Control 2 SW2 Switch #4 on = SELF-DIAGNOSTICSData Terminal Ready DTR Signal Options Reconfigure Switch ModeReset Options 5 RS-232 PASS-THROUGH OptionsBaud Rate Options Clear to Send CTS Signal OptionsModem or DIRECT-TO-TERMINAL Connection Carrier Options Preparing the A/S-2G for Connection to a Synchronous DeviceCable Requirement External or Internal Clocking Option Command PASS-THRU Operation Asynchronous Device to Synchronous DeviceUSE of Carriage Return a 2770/2780 Mode Flow ControlVerification of Data Reception Presentation of Data from A/S-2G to Synchronous DeviceLine Turnaround Data Flow A/S-2G to Synchronous Device NAK Echo CR LF Send block F Echo all but CR LF Data Flow A/S-2G to Synchronous Device Synchronous Device to Asynchronous Device Synchronous Input Data FormatEbcdic characters stripped Data Flow A/S-2G to Asynchronous Device Operation EOT Installing or Replacing Proms Transparency Mode of OperationConversions and Connections RS-232 Cable Chart GNDCode Conversions Special Conversions Printed Circuit Board Layout Printed Board Circuit LayoutPark Drive Lawrence, PA