Kathrein CAP 600 manual Version with External Cable Gland FIG. F

Page 16

INSTALLATION AND CONNECTION

VERSION WITH EXTERNAL CABLE GLAND (FIG. F)

Direction of travel

Cables laid in

the cable duct*) and water-tight roof gland*)

*) Not included! Watertight cable ducts are used in boating and yachting applications under the name “cable ports”; they can be purchased from boating and yachting chandlers.

The external cable gland should not be so far from the turntable that the junction between the two cables projecting from the turntable and the extension cables cannot lie within the interior of the vehicle.

Arrange the cables in the cable duct when placing the turntable on to the mounting plate. Make sure that the cables are not crossed over and that they are taut so that they cannot be crushed. Do not try to pull the cables from the unit. This could damage the cables or loosen the cable connections.

Place the turntable carefully on the mounting plate. The through holes on the turntable must be perfectly aligned with the threads on the mounting plate.

Apply a little adhesive sealant to the six threaded holes in the mounting plate and screw the fastening screws into the thread. Tighten the screws to a torque of 6 Nm.

The connecting cables should be fed¹) into the interior of the vehicle through a waterproof cable gland. In so doing the cables may not be crushed, kinked or damaged.

¹) These watertight cable glands are used in boating and yachting applications under the name “cable ports”; they can be purchased from boating and yachting chandlers.

16

Image 16
Contents CAP Contents Disposal Instructions Foreign Language Installation MANUAL/DISPOSALUsed batteries are special waste Mobiset 2 CAP 600 COMPONENTS/SCOPE of Delivery Product PackageProper USE Proper USE USE for the Intended PurposeFundamental information Safety Instructions Important NotesAdhesive sealant Power supply, fusing Road Traffic Licensing Regulations StVZOChecks before commencing a journey Installation and Connection Selecting the Installation LocationRequired Tools and Equipment Unpacking and PreparationDirection of travel Installation Steps Installation and Connection Installation and Connection Installation of Turntable Figure E Version with External Cable Gland FIG. F Brief Instructions for Installing the Turntable Tightening torque 6 Nm Suspended Installation Installation on a Fixed Flat Surface Reversal is not possible unit will not function Installation and Connection Connection Example for 12 V Battery Connection Reception RANGE/FOOTPRINT Address of the Service Centre Dismantling for ServicingESC DismantlingPolarisation Setting Polarisation SettingSafety Notes Installation Process On the TurntableView after installation +15 Middle standardManual Lowering to Park Position Manual Lowering Technical Data Dimensions MMTechnical Data Type CAP LNBSikaflex 291 Safety Data Sheet Materials/preparation and company designationComposition/data on components Potential hazardsMeasures for fire fighting Measures if inadvertently releasedHandling and storage Exposure limitation and personal protective equipmentPhysical and chemical characteristics Stability and reactivityToxicology data Sensitisation Ecological dataDisposal instructions Transport dataOther data Sikaflex 291 Technical Data Sheet Sikaflex-291 AflexChemical Stability CAP 600 Operating Manual Important Information for CAP 600 Before Setup Remote ControlFirst Installation Picture format TV-SCART-OutputSystem Local time offsetAlignment Satellite Search Manual Correction Channel Satellite Selection Channel Selection from the Channel ListChange of LOCATION/TIMER Programming Timer ProgrammingRESET/PARKING Resetting the Motorised AntennaParking the Turntable Special Messages from the Turntable System Protection MessagesSpecial Messages from the Turntable Messages Arising from Software Problems Further Messages Declaration of Conformity EC Declaration of ConformityFor Your Notes For Your Notes 936.3220/-/0907/ZWT Technical data subject to change
Related manuals
Manual 1 pages 4.49 Kb

CAP 600 specifications

The Kathrein CAP 600 is a cutting-edge solution designed for the modern telecommunications landscape, catering primarily to the demands of mobile network operators and service providers. This compact, high-performance active antenna system is engineered to enhance connectivity in urban environments, significantly improving network efficiency and user experience.

One of the key features of the Kathrein CAP 600 is its multi-band capability. It supports various frequency bands including LTE, 5G NR, and others, making it versatile for both current and future network deployments. This allows operators to seamlessly upgrade their services without needing to overhaul their infrastructure.

The CAP 600 is equipped with advanced MIMO (Multiple Input Multiple Output) technology, which leverages multiple antennas at both transmitting and receiving ends to boost data throughput and reliability. This technology is essential for maximizing spectral efficiency, thus accommodating more users and higher data rates in dense urban areas.

In terms of design, the Kathrein CAP 600 features a compact and lightweight structure. This is crucial for installations in constrained environments where space is at a premium. The antenna's sleek aesthetics also allow it to blend into its surroundings, thereby reducing visual impact, which is often a concern in urban deployments.

The antenna incorporates intelligent software features that facilitate dynamic beamforming. This enables targeted coverage, allowing signals to be directed towards users rather than being broadcast in all directions, thus minimizing interference and optimizing network performance. Additionally, the built-in remote management capabilities allow operators to monitor and manage network performance in real-time, enhancing operational efficiency.

Regarding sustainability, the CAP 600 is designed with energy efficiency in mind. The use of advanced materials and optimized hardware contributes to lower energy consumption, making it an environmentally friendly choice for operators looking to reduce their carbon footprint.

Overall, the Kathrein CAP 600 is a sophisticated solution that meets the high demands of modern mobile networks. With its advanced features, technologies, and commitment to sustainable operations, it represents a pivotal component for any operator looking to enhance connectivity and provide exceptional service in today’s dynamic telecommunications environment.