Kathrein CAP 600 manual Installation Process, On the Turntable

Page 28

POLARISATION SETTING

INSTALLATION PROCESS

The explanation of this installation process is based on the assumption that the entire CAP unit has been properly put together, installed and set up, as described in this installation manual. The safety instructions in the detailed operating manual for the UFS 740sw must also be followed!

To dismantle/install the planar antenna from the turntable, proceed as follows: (the key names refer to the remote control for the UFS 740sw receiver)

1.Turn on the receiver at the main switch on the front of the unit.

2.Pressing any of the numeric buttons will bring the receiver into operating mode.

3.If necessary, first perform a first installation

4.Wait until the message “Position of Astra is not known. Start a search?” is displayed – cancel this procedure by pressing the  button.

5.Next, press the  button to go to the main menu and use the  buttons to move to the menu item “Settings”. Confirm the selection by pressing the  button.

6.Use the  buttons to move to the menu item “Antenna Configuration”. Confirm the selection by pressing the  button.

7.Use the  buttons to select the Elevation menu item and use the numeric pad on the remote control to enter “400”.

8.Press the  button and the turntable will move to the selected elevation angle.

9.Turn off the UFS 740 using the main switch on the front and disconnect it from the power.

10.Unscrew the antenna fastening screws on the turntable with a suitable hexagon key (size 5), see photograph on the right.

11.Carefully lift the antenna off the turntable and exchange the slot for the rubber bushing with cable and the relevant dummy bushing (depending on the direction you want to move the antenna).

ON THE TURNTABLE

Point 9.

12.You can now refit the antenna with the desired change of angle (+15° or -15°) (see picture on the right).

13.Tighten the hexagon socket screws to a torque of 6-7 Nm.

14.Leave the installation location and reconnect the UFS 740sw to the power supply.

28

Image 28
Contents CAP Contents Disposal Instructions Foreign Language Installation MANUAL/DISPOSALUsed batteries are special waste Mobiset 2 CAP 600 COMPONENTS/SCOPE of Delivery Product PackageProper USE Proper USE USE for the Intended PurposeFundamental information Safety Instructions Important NotesAdhesive sealant Power supply, fusing Road Traffic Licensing Regulations StVZOChecks before commencing a journey Installation and Connection Selecting the Installation LocationRequired Tools and Equipment Unpacking and PreparationDirection of travel Installation Steps Installation and Connection Installation and Connection Installation of Turntable Figure E Version with External Cable Gland FIG. F Brief Instructions for Installing the Turntable Tightening torque 6 Nm Suspended Installation Installation on a Fixed Flat Surface Reversal is not possible unit will not function Installation and Connection Connection Example for 12 V Battery Connection Reception RANGE/FOOTPRINT Address of the Service Centre Dismantling for ServicingESC DismantlingPolarisation Setting Polarisation SettingSafety Notes Installation Process On the TurntableView after installation +15 Middle standardManual Lowering to Park Position Manual Lowering Technical Data Dimensions MMTechnical Data Type CAP LNBSikaflex 291 Safety Data Sheet Materials/preparation and company designationComposition/data on components Potential hazardsMeasures for fire fighting Measures if inadvertently releasedHandling and storage Exposure limitation and personal protective equipmentPhysical and chemical characteristics Stability and reactivityToxicology data Sensitisation Ecological dataDisposal instructions Transport dataOther data Sikaflex 291 Technical Data Sheet Sikaflex-291 AflexChemical Stability CAP 600 Operating Manual Important Information for CAP 600 Before Setup Remote ControlFirst Installation Picture format TV-SCART-OutputSystem Local time offsetAlignment Satellite Search Manual Correction Channel Satellite Selection Channel Selection from the Channel ListChange of LOCATION/TIMER Programming Timer ProgrammingRESET/PARKING Resetting the Motorised AntennaParking the Turntable Special Messages from the Turntable System Protection MessagesSpecial Messages from the Turntable Messages Arising from Software Problems Further Messages Declaration of Conformity EC Declaration of ConformityFor Your Notes For Your Notes 936.3220/-/0907/ZWT Technical data subject to change
Related manuals
Manual 1 pages 4.49 Kb

CAP 600 specifications

The Kathrein CAP 600 is a cutting-edge solution designed for the modern telecommunications landscape, catering primarily to the demands of mobile network operators and service providers. This compact, high-performance active antenna system is engineered to enhance connectivity in urban environments, significantly improving network efficiency and user experience.

One of the key features of the Kathrein CAP 600 is its multi-band capability. It supports various frequency bands including LTE, 5G NR, and others, making it versatile for both current and future network deployments. This allows operators to seamlessly upgrade their services without needing to overhaul their infrastructure.

The CAP 600 is equipped with advanced MIMO (Multiple Input Multiple Output) technology, which leverages multiple antennas at both transmitting and receiving ends to boost data throughput and reliability. This technology is essential for maximizing spectral efficiency, thus accommodating more users and higher data rates in dense urban areas.

In terms of design, the Kathrein CAP 600 features a compact and lightweight structure. This is crucial for installations in constrained environments where space is at a premium. The antenna's sleek aesthetics also allow it to blend into its surroundings, thereby reducing visual impact, which is often a concern in urban deployments.

The antenna incorporates intelligent software features that facilitate dynamic beamforming. This enables targeted coverage, allowing signals to be directed towards users rather than being broadcast in all directions, thus minimizing interference and optimizing network performance. Additionally, the built-in remote management capabilities allow operators to monitor and manage network performance in real-time, enhancing operational efficiency.

Regarding sustainability, the CAP 600 is designed with energy efficiency in mind. The use of advanced materials and optimized hardware contributes to lower energy consumption, making it an environmentally friendly choice for operators looking to reduce their carbon footprint.

Overall, the Kathrein CAP 600 is a sophisticated solution that meets the high demands of modern mobile networks. With its advanced features, technologies, and commitment to sustainable operations, it represents a pivotal component for any operator looking to enhance connectivity and provide exceptional service in today’s dynamic telecommunications environment.